Newer
Older
* @version $URL$
* $Id$
* @desc This module provides test cases for S1AP tests.
* @copyright ETSI Copyright Notification
* No part may be reproduced except as authorized by written permission.
* The copyright and the foregoing restriction extend to reproduction in all media.
* All rights reserved.
* @see ETSI TS 136 413 / 3GPP TS 36.413 version 13.4.0 Release 13
import from S1AP_TestConfiguration all;
import from S1AP_TestSystem all;
import from S1AP_TCFunctions all;
/**
* @desc E-RAB management group
* @see ETSI TS 103 497-2 Clause 5.2.2.1.2 E-RAB management group
*/
/**
* @desc Verify that the IUT can successfully process all mandatory IEs in an E-RAB_SETUP_REQUEST received
* due to E-RAB management procedure and send E-RAB_SETUP_RESPONSE with successfully established E-RABs
* included in the E-RAB_Setup_List IE.
* <pre>
* Configuration: CF_S1-MME
* Ensure that the IUT
* on receipt of an E-RAB_SETUP_REQUEST
* containing an MME_UE_S1AP_ID
* containing an eNB_UE_S1AP_ID
* containing an E-RAB_to_be_Setup_List
* containing an E-RAB_to_be_Setup Item 1
* containing an E-RAB_ID
* containing an E-RAB_Level_QoS_Parameters
* containing QCI
* indicating value 5
* containing a Transport_Layer_Address
* containing a GTP-TEID
* containing a NAS-PDU
* sends an E-RAB_SETUP_RESPONSE
* containing an MME_UE_S1AP_ID
* containing an eNB_UE_S1AP_ID
* containing an E-RAB_Setup_List
* containing an E-RAB_Setup Item 1
* containing an E-RAB_ID
* containing a Transport_Layer_Address
* containing a GTP-TEID.
* </pre>
*
* @see ETSI TS 103 497-2 TP_S1AP_eNB_RAB_01
* @reference ETSI TS 136 413 V13.4.0 Clause 8.2.1.2(1st dashed line in 5th dashed list) and 9.1.3.1 and 9.1.3.2
*/
testcase TC_S1AP_eNB_RAB_01() runs on S1AP system TestAdapter {
// Local variables
var S1AP v_s1ap_enb;
// Test control
if (not PICS_S1AP_eNB_IUT) {
log("*** " & __SCOPE__ & ": ERROR: 'PICS_S1AP_eNB_IUT' shall be set to true for executing the TC. ***");
stop;
}
// Test component configuration
// synchronize PTC on 1 sychronization points
f_serverSyncNClientsAndStop(1, {c_prDone, c_tbDone, c_poDone});
/**
* @desc Verify that the IUT after receiving an E-RAB_SETUP_REQUEST with failed E-RAB sends an E-RAB_SETUP_RESPONSE
* with E-RAB_Failed_to_Setup_List.
* <pre>
93
94
95
96
97
98
99
100
101
102
103
104
105
106
107
108
109
110
111
112
113
114
115
116
117
118
119
120
121
122
123
124
125
126
127
128
129
130
131
* Configuration: CF_S1-MME
* Ensure that the IUT
* on receipt of an E-RAB_SETUP_REQUEST
* containing an MME_UE_S1AP_ID
* containing an eNB_UE_S1AP_ID
* containing an E-RAB_to_be_Setup_List
* containing an E-RAB_to_be_Setup Item 1
* containing an E-RAB_ID
* indicating value A
* containing an E-RAB_Level_QoS_Parameters
* containing a Transport_Layer_Address
* containing a GTP-TEID
* containing a NAS-PDU
* containing an E-RAB_to_be_Setup Item 2(not acceptable data for eNB)
* containing an E-RAB_ID
* indicating value B(different to value A)
* containing an E-RAB_Level_QoS_Parameters
* containing QCI
* indicating not supported QCI value(255)
* containing a Transport_Layer_Address
* containing a GTP-TEID
* containing a NAS-PDU
* sends an E-RAB_SETUP_RESPONSE
* containing an MME_UE_S1AP_ID
* containing an eNB_UE_S1AP_ID
* containing an E-RAB_Setup_List
* containing an E-RAB_Setup Item 1
* containing an E-RAB_ID
* indicating value A
* containing a Transport_Layer_Address
* containing a GTP-TEID
* containing an E-RAB_Failed_to_Setup_List
* containing an E-RAB_List Item 1
* containing an E-RAB_ID
* indicating value B
* containing a Cause
* indicating ‘not-supported-QCI-value’.
* </pre>
*
* @see ETSI TS 103 497-2 TP_S1AP_eNB_RAB_02
* @reference ETSI TS 136 413 V13.4.0 Clause 8.2.1.2(2nd dashed line in 5th dashed list) and 9.1.3.1 and 9.1.3.2
*/
testcase TC_S1AP_eNB_RAB_02() runs on S1AP system TestAdapter {
// Local variables
var S1AP v_s1ap_enb;
// Test control
if (not PICS_S1AP_eNB_IUT) {
log("*** " & __SCOPE__ & ": ERROR: 'PICS_S1AP_eNB_IUT' shall be set to true for executing the TC. ***");
stop;
}
// Test component configuration
f_cf_S1AP_eNB_Up(v_s1ap_enb);
// Start
// synchronize PTC on 1 sychronization points
f_serverSyncNClientsAndStop(1, {c_prDone, c_tbDone, c_poDone});
f_cf_Down();
group Context_Management_group {
testcase TC_S1AP_eNB_CMP_01() runs on S1AP system TestAdapter {
// Local variables
var S1AP v_s1ap_enb;
// Test control
if (not PICS_S1AP_eNB_IUT) {
log("*** " & __SCOPE__ & ": ERROR: 'PICS_S1AP_eNB_IUT' shall be set to true for executing the TC. ***");
stop;
}
// Test component configuration
f_cf_S1AP_eNB_Up(v_s1ap_enb);
// Start
v_s1ap_enb.start(f_TC_S1AP_eNB_CMP_01());
// synchronize PTC on 1 sychronization points
f_serverSyncNClientsAndStop(1, {c_prDone, c_tbDone, c_poDone});
f_cf_Down();
} // End of testcase TC_S1AP_eNB_CMP_01
testcase TC_S1AP_eNB_CMP_02() runs on S1AP system TestAdapter {
// Local variables
var S1AP v_s1ap_enb;
// Test control
if (not PICS_S1AP_eNB_IUT) {
log("*** " & __SCOPE__ & ": ERROR: 'PICS_S1AP_eNB_IUT' shall be set to true for executing the TC. ***");
stop;
}
// Test component configuration
f_cf_S1AP_eNB_Up(v_s1ap_enb);
// Start
v_s1ap_enb.start(f_TC_S1AP_eNB_CMP_02());
// synchronize PTC on 1 sychronization points
f_serverSyncNClientsAndStop(1, {c_prDone, c_tbDone, c_poDone});
f_cf_Down();
} // End of testcase TC_S1AP_eNB_CMP_02
testcase TC_S1AP_eNB_CMP_03() runs on S1AP system TestAdapter {
// Local variables
var S1AP v_s1ap_enb;
// Test control
if (not PICS_S1AP_eNB_IUT) {
log("*** " & __SCOPE__ & ": ERROR: 'PICS_S1AP_eNB_IUT' shall be set to true for executing the TC. ***");
stop;
}
// Test component configuration
f_cf_S1AP_eNB_Up(v_s1ap_enb);
// Start
v_s1ap_enb.start(f_TC_S1AP_eNB_CMP_03());
// synchronize PTC on 1 sychronization points
f_serverSyncNClientsAndStop(1, {c_prDone, c_tbDone, c_poDone});
f_cf_Down();
} // End of testcase TC_S1AP_eNB_CMP_03
testcase TC_S1AP_eNB_CMP_04() runs on S1AP system TestAdapter {
// Local variables
var S1AP v_s1ap_enb;
// Test control
if (not PICS_S1AP_eNB_IUT) {
log("*** " & __SCOPE__ & ": ERROR: 'PICS_S1AP_eNB_IUT' shall be set to true for executing the TC. ***");
stop;
}
// Test component configuration
f_cf_S1AP_eNB_Up(v_s1ap_enb);
// Start
v_s1ap_enb.start(f_TC_S1AP_eNB_CMP_04());
// synchronize PTC on 1 sychronization points
f_serverSyncNClientsAndStop(1, {c_prDone, c_tbDone, c_poDone});
f_cf_Down();
} // End of testcase TC_S1AP_eNB_CMP_04
testcase TC_S1AP_eNB_CMP_05() runs on S1AP system TestAdapter {
// Local variables
var S1AP v_s1ap_enb;
// Test control
if (not PICS_S1AP_eNB_IUT) {
log("*** " & __SCOPE__ & ": ERROR: 'PICS_S1AP_eNB_IUT' shall be set to true for executing the TC. ***");
stop;
}
// Test component configuration
f_cf_S1AP_eNB_Up(v_s1ap_enb);
// Start
v_s1ap_enb.start(f_TC_S1AP_eNB_CMP_05());
// synchronize PTC on 1 sychronization points
f_serverSyncNClientsAndStop(1, {c_prDone, c_tbDone, c_poDone});
f_cf_Down();
} // End of testcase TC_S1AP_eNB_CMP_05
testcase TC_S1AP_eNB_CMP_06() runs on S1AP system TestAdapter {
// Local variables
var S1AP v_s1ap_enb;
// Test control
if (not PICS_S1AP_eNB_IUT) {
log("*** " & __SCOPE__ & ": ERROR: 'PICS_S1AP_eNB_IUT' shall be set to true for executing the TC. ***");
stop;
}
// Test component configuration
f_cf_S1AP_eNB_Up(v_s1ap_enb);
// Start
v_s1ap_enb.start(f_TC_S1AP_eNB_CMP_06());
// synchronize PTC on 1 sychronization points
f_serverSyncNClientsAndStop(1, {c_prDone, c_tbDone, c_poDone});
f_cf_Down();
} // End of testcase TC_S1AP_eNB_CMP_06
testcase TC_S1AP_eNB_CMP_07() runs on S1AP system TestAdapter {
// Local variables
var S1AP v_s1ap_enb;
// Test control
if (not PICS_S1AP_eNB_IUT) {
log("*** " & __SCOPE__ & ": ERROR: 'PICS_S1AP_eNB_IUT' shall be set to true for executing the TC. ***");
stop;
}
// Test component configuration
f_cf_S1AP_eNB_Up(v_s1ap_enb);
// Start
v_s1ap_enb.start(f_TC_S1AP_eNB_CMP_07());
// synchronize PTC on 1 sychronization points
f_serverSyncNClientsAndStop(1, {c_prDone, c_tbDone, c_poDone});
f_cf_Down();
} // End of testcase TC_S1AP_eNB_CMP_07
testcase TC_S1AP_eNB_CMP_08() runs on S1AP system TestAdapter {
// Local variables
var S1AP v_s1ap_enb;
// Test control
if (not PICS_S1AP_eNB_IUT) {
log("*** " & __SCOPE__ & ": ERROR: 'PICS_S1AP_eNB_IUT' shall be set to true for executing the TC. ***");
stop;
}
// Test component configuration
f_cf_S1AP_eNB_Up(v_s1ap_enb);
// Start
v_s1ap_enb.start(f_TC_S1AP_eNB_CMP_08());
// synchronize PTC on 1 sychronization points
f_serverSyncNClientsAndStop(1, {c_prDone, c_tbDone, c_poDone});
f_cf_Down();
} // End of testcase TC_S1AP_eNB_CMP_08
testcase TC_S1AP_eNB_CMP_09() runs on S1AP system TestAdapter {
// Local variables
var S1AP v_s1ap_enb;
// Test control
if (not PICS_S1AP_eNB_IUT) {
log("*** " & __SCOPE__ & ": ERROR: 'PICS_S1AP_eNB_IUT' shall be set to true for executing the TC. ***");
stop;
}
// Test component configuration
f_cf_S1AP_eNB_Up(v_s1ap_enb);
// Start
v_s1ap_enb.start(f_TC_S1AP_eNB_CMP_09());
// synchronize PTC on 1 sychronization points
f_serverSyncNClientsAndStop(1, {c_prDone, c_tbDone, c_poDone});
f_cf_Down();
} // End of testcase TC_S1AP_eNB_CMP_09
testcase TC_S1AP_eNB_CMP_10() runs on S1AP system TestAdapter {
// Local variables
var S1AP v_s1ap_enb;
// Test control
if (not PICS_S1AP_eNB_IUT) {
log("*** " & __SCOPE__ & ": ERROR: 'PICS_S1AP_eNB_IUT' shall be set to true for executing the TC. ***");
stop;
}
// Test component configuration
f_cf_S1AP_eNB_Up(v_s1ap_enb);
// Start
v_s1ap_enb.start(f_TC_S1AP_eNB_CMP_10());
// synchronize PTC on 1 sychronization points
f_serverSyncNClientsAndStop(1, {c_prDone, c_tbDone, c_poDone});
f_cf_Down();
} // End of testcase TC_S1AP_eNB_CMP_10
testcase TC_S1AP_eNB_CMP_11() runs on S1AP system TestAdapter {
// Local variables
var S1AP v_s1ap_enb;
// Test control
if (not PICS_S1AP_eNB_IUT) {
log("*** " & __SCOPE__ & ": ERROR: 'PICS_S1AP_eNB_IUT' shall be set to true for executing the TC. ***");
stop;
}
// Test component configuration
f_cf_S1AP_eNB_Up(v_s1ap_enb);
// Start
v_s1ap_enb.start(f_TC_S1AP_eNB_CMP_11());
// synchronize PTC on 1 sychronization points
f_serverSyncNClientsAndStop(1, {c_prDone, c_tbDone, c_poDone});
f_cf_Down();
} // End of testcase TC_S1AP_eNB_CMP_11
testcase TC_S1AP_eNB_CMP_12() runs on S1AP system TestAdapter {
// Local variables
var S1AP v_s1ap_enb;
// Test control
if (not PICS_S1AP_eNB_IUT) {
log("*** " & __SCOPE__ & ": ERROR: 'PICS_S1AP_eNB_IUT' shall be set to true for executing the TC. ***");
stop;
}
// Test component configuration
f_cf_S1AP_eNB_Up(v_s1ap_enb);
// Start
v_s1ap_enb.start(f_TC_S1AP_eNB_CMP_12());
// synchronize PTC on 1 sychronization points
f_serverSyncNClientsAndStop(1, {c_prDone, c_tbDone, c_poDone});
f_cf_Down();
} // End of testcase TC_S1AP_eNB_CMP_12
testcase TC_S1AP_eNB_CMP_13() runs on S1AP system TestAdapter {
// Local variables
var S1AP v_s1ap_enb;
// Test control
if (not PICS_S1AP_eNB_IUT) {
log("*** " & __SCOPE__ & ": ERROR: 'PICS_S1AP_eNB_IUT' shall be set to true for executing the TC. ***");
stop;
}
// Test component configuration
f_cf_S1AP_eNB_Up(v_s1ap_enb);
// Start
v_s1ap_enb.start(f_TC_S1AP_eNB_CMP_13());
// synchronize PTC on 1 sychronization points
f_serverSyncNClientsAndStop(1, {c_prDone, c_tbDone, c_poDone});
f_cf_Down();
} // End of testcase TC_S1AP_eNB_CMP_13
testcase TC_S1AP_eNB_CMP_14() runs on S1AP system TestAdapter {
// Local variables
var S1AP v_s1ap_enb;
// Test control
if (not PICS_S1AP_eNB_IUT) {
log("*** " & __SCOPE__ & ": ERROR: 'PICS_S1AP_eNB_IUT' shall be set to true for executing the TC. ***");
stop;
}
// Test component configuration
f_cf_S1AP_eNB_Up(v_s1ap_enb);
// Start
v_s1ap_enb.start(f_TC_S1AP_eNB_CMP_14());
// synchronize PTC on 1 sychronization points
f_serverSyncNClientsAndStop(1, {c_prDone, c_tbDone, c_poDone});
f_cf_Down();
} // End of testcase TC_S1AP_eNB_CMP_14
testcase TC_S1AP_eNB_CMP_15() runs on S1AP system TestAdapter {
// Local variables
var S1AP v_s1ap_enb;
// Test control
if (not PICS_S1AP_eNB_IUT) {
log("*** " & __SCOPE__ & ": ERROR: 'PICS_S1AP_eNB_IUT' shall be set to true for executing the TC. ***");
stop;
}
// Test component configuration
f_cf_S1AP_eNB_Up(v_s1ap_enb);
// Start
v_s1ap_enb.start(f_TC_S1AP_eNB_CMP_15());
// synchronize PTC on 1 sychronization points
f_serverSyncNClientsAndStop(1, {c_prDone, c_tbDone, c_poDone});
f_cf_Down();
} // End of testcase TC_S1AP_eNB_CMP_15
testcase TC_S1AP_eNB_CMP_16() runs on S1AP system TestAdapter {
// Local variables
var S1AP v_s1ap_enb;
// Test control
if (not PICS_S1AP_eNB_IUT) {
log("*** " & __SCOPE__ & ": ERROR: 'PICS_S1AP_eNB_IUT' shall be set to true for executing the TC. ***");
stop;
}
// Test component configuration
f_cf_S1AP_eNB_Up(v_s1ap_enb);
// Start
v_s1ap_enb.start(f_TC_S1AP_eNB_CMP_16());
// synchronize PTC on 1 sychronization points
f_serverSyncNClientsAndStop(1, {c_prDone, c_tbDone, c_poDone});
f_cf_Down();
} // End of testcase TC_S1AP_eNB_CMP_16
testcase TC_S1AP_eNB_CMP_17() runs on S1AP system TestAdapter {
// Local variables
var S1AP v_s1ap_enb;
// Test control
if (not PICS_S1AP_eNB_IUT) {
log("*** " & __SCOPE__ & ": ERROR: 'PICS_S1AP_eNB_IUT' shall be set to true for executing the TC. ***");
stop;
}
// Test component configuration
f_cf_S1AP_eNB_Up(v_s1ap_enb);
// Start
v_s1ap_enb.start(f_TC_S1AP_eNB_CMP_17());
// synchronize PTC on 1 sychronization points
f_serverSyncNClientsAndStop(1, {c_prDone, c_tbDone, c_poDone});
f_cf_Down();
} // End of testcase TC_S1AP_eNB_CMP_17
testcase TC_S1AP_eNB_CMP_18() runs on S1AP system TestAdapter {
// Local variables
var S1AP v_s1ap_enb;
// Test control
if (not PICS_S1AP_eNB_IUT) {
log("*** " & __SCOPE__ & ": ERROR: 'PICS_S1AP_eNB_IUT' shall be set to true for executing the TC. ***");
stop;
}
// Test component configuration
f_cf_S1AP_eNB_Up(v_s1ap_enb);
// Start
v_s1ap_enb.start(f_TC_S1AP_eNB_CMP_18());
// synchronize PTC on 1 sychronization points
f_serverSyncNClientsAndStop(1, {c_prDone, c_tbDone, c_poDone});
f_cf_Down();
} // End of testcase TC_S1AP_eNB_CMP_18
testcase TC_S1AP_eNB_CMP_19() runs on S1AP system TestAdapter {
// Local variables
var S1AP v_s1ap_enb;
// Test control
if (not PICS_S1AP_eNB_IUT) {
log("*** " & __SCOPE__ & ": ERROR: 'PICS_S1AP_eNB_IUT' shall be set to true for executing the TC. ***");
stop;
}
// Test component configuration
f_cf_S1AP_eNB_Up(v_s1ap_enb);
// Start
v_s1ap_enb.start(f_TC_S1AP_eNB_CMP_19());
// synchronize PTC on 1 sychronization points
f_serverSyncNClientsAndStop(1, {c_prDone, c_tbDone, c_poDone});
f_cf_Down();
} // End of testcase TC_S1AP_eNB_CMP_19
} // End of group Context_Management_group
* @see ETSI TS 103 497-2 Clause 5.2.2.1.6 NAS transport group
*/
group NAS_transport_group {
/**
* @desc Verify that the IUT can send an INITIAL_UE_MESSAGE to indicate the initiation of a NAS Transport procedure.
* <pre>
* Configuration: CF_S1-MME
* Ensure that the IUT
* to indicate the initiation of a NAS Transport procedure
* sends an INITIAL_UE_MESSAGE
* containing an eNB_UE_S1AP_ID
* containing a NAS-PDU
* containg a TAI
* containing a PLMN_Identity
* containing a TAC
* containing an E-UTRAN_CGI
* containing a PLMN_Identity
* containing a Cell_Identity
* containing a RRC_Establishment_Cause.
* </pre>
*
* @see ETSI TS 103 497-2 TP_S1AP_eNB_NAS_01
642
643
644
645
646
647
648
649
650
651
652
653
654
655
656
657
658
659
660
661
662
663
664
665
666
667
668
669
* @reference ETSI TS 136 413 V13.4.0 Clause 8.6.2.1¶1 and 9.1.7.1
*/
testcase TC_S1AP_eNB_NAS_01() runs on S1AP system TestAdapter {
// Local variables
var S1AP v_s1ap_enb;
// Test control
if (not PICS_S1AP_eNB_IUT) {
log("*** " & __SCOPE__ & ": ERROR: 'PICS_S1AP_eNB_IUT' shall be set to true for executing the TC. ***");
stop;
}
// Test component direct information
f_cf_S1AP_eNB_Up(v_s1ap_enb);
// Start
v_s1ap_enb.start(f_TC_S1AP_eNB_NAS_01());
// synchronize PTC on 1 sychronization points
f_serverSyncNClientsAndStop(1, {c_prDone, c_tbDone, c_poDone});
f_cf_Down();
} // End of testcase TC_S1AP_eNB_NAS_01
/**
* @desc Verify that the IUT can send an UPLINK_NAS_TRANSPORT to indicate an ongoing NAS Transport procedure.
* <pre>
* Configuration: CF_S1-MME
* Ensure that the IUT
* to indicate an ongoing NAS Transport procedure
* sends an UPLINK_NAS_TRANSPORT
* containing an MME UE S1AP ID
* containing an eNB_UE_S1AP_ID
* containing a NAS-PDU
* containg a TAI
* containing a PLMN_Identity
* containing a TAC
* containing an E-UTRAN_CGI
* containing a PLMN_Identity
* containing a Cell_Identity
* containing a RRC_Establishment_Cause.
* </pre>
*
* @see ETSI TS 103 497-2 TP_S1AP_eNB_NAS_02
688
689
690
691
692
693
694
695
696
697
698
699
700
701
702
703
704
705
706
707
708
709
710
711
712
713
714
715
* @reference ETSI TS 136 413 V13.4.0 Clause 8.6.2.3¶1 and 9.1.7.3
*/
testcase TC_S1AP_eNB_NAS_02() runs on S1AP system TestAdapter {
// Local variables
var S1AP v_s1ap_enb;
// Test control
if (not PICS_S1AP_eNB_IUT) {
log("*** " & __SCOPE__ & ": ERROR: 'PICS_S1AP_eNB_IUT' shall be set to true for executing the TC. ***");
stop;
}
// Test component direct information
f_cf_S1AP_eNB_Up(v_s1ap_enb);
// Start
v_s1ap_enb.start(f_TC_S1AP_eNB_NAS_02());
// synchronize PTC on 1 sychronization points
f_serverSyncNClientsAndStop(1, {c_prDone, c_tbDone, c_poDone});
f_cf_Down();
} // End of testcase TC_S1AP_eNB_NAS_02
/**
* @desc Verify that the IUT can send a NAS_NON_DELIVERY_INDICATION to indicate the eNB was unable to ensure that the message has been received by the UE.
* <pre>
* Configuration: CF_S1-MME
* Ensure that the IUT
* to indicate a UE has not received a INITIAL_UE_MESSAGE
* sends a NAS_NON_DELIVERY_INDICATION
* containing an MME UE S1AP ID
* containing an eNB_UE_S1AP_ID
* containing a NAS-PDU
* containing a Cause
* indicating an appropriate cause value.
* </pre>
*
* @see ETSI TS 103 497-2 TP_S1AP_eNB_NAS_03
729
730
731
732
733
734
735
736
737
738
739
740
741
742
743
744
745
746
747
748
749
750
751
752
753
754
755
* @reference ETSI TS 136 413 V13.4.0 Clause 8.6.2.4 and 9.1.7.4
*/
testcase TC_S1AP_eNB_NAS_03() runs on S1AP system TestAdapter {
// Local variables
var S1AP v_s1ap_enb;
// Test control
if (not PICS_S1AP_eNB_IUT) {
log("*** " & __SCOPE__ & ": ERROR: 'PICS_S1AP_eNB_IUT' shall be set to true for executing the TC. ***");
stop;
}
// Test component direct information
f_cf_S1AP_eNB_Up(v_s1ap_enb);
// Start
v_s1ap_enb.start(f_TC_S1AP_eNB_NAS_03());
// synchronize PTC on 1 sychronization points
f_serverSyncNClientsAndStop(1, {c_prDone, c_tbDone, c_poDone});
f_cf_Down();
} // End of testcase TC_S1AP_eNB_NAS_03
} // End of group group NAS_transport_group
* @desc Management group
* @see ETSI TS 103 497-2 Clause 5.2.2.1.7 Management group
*/
group Management_group {
/**
* @desc Verify that the IUT can successfully process all mandatory IEs in a RESET and sends a RESET_ACKNOWLEDGE due to a Reset procedure initiated from the MME.
* Ensure that the IUT
* on receipt of a RESET
* containing a Cause
* indicating an appropriate cause value
* containing a Reset_Type
* containing a S1_Interface
* indicating a value ‘Reset_all’
* sends a RESET_ACKNOWLEDGE
* containing a UE-associated_logical_S1-connection_list.
* </pre>
*
* @see ETSI TS 103 497-2 TP_S1AP_eNB_MNP_01
* @reference ETSI TS 136 413 V13.4.0 Clause 8.7.1.2.1¶2 and 9.1.8.1 and 9.1.8.2
*/
testcase TC_S1AP_eNB_MNP_01() runs on S1AP system TestAdapter {
// Local variables
var S1AP v_s1ap_enb;
// Test control
if (not PICS_S1AP_eNB_IUT) {
log("*** " & __SCOPE__ & ": ERROR: 'PICS_S1AP_eNB_IUT' shall be set to true for executing the TC. ***");
stop;
}
// Test component direct information
f_cf_S1AP_eNB_Up(v_s1ap_enb);
// Start
// synchronize PTC on 1 sychronization points
f_serverSyncNClientsAndStop(1, {c_prDone, c_tbDone, c_poDone});
f_cf_Down();
/**
* @desc Verify that the IUT can send an RESET due to a Reset procedure initiated from the E-UTRAN.
* <pre>
* Ensure that the IUT
* to indicate a Reset procedure initiated from the E-UTRAN
* containing a Cause
* indicating an appropriate cause value
* containing a Reset_Type
* containing a S1_Interface
* indicating a value ‘Reset_all’.
* </pre>
*
* @see ETSI TS 103 497-2 TP_S1AP_eNB_MNP_02
* @reference ETSI TS 136 413 V13.4.0 Clause 8.7.1.2.2¶1 and 9.1.8.1 and 9.1.8.2
*/
testcase TC_S1AP_eNB_MNP_02() runs on S1AP system TestAdapter {
// Local variables
var S1AP v_s1ap_enb;
// Test control
if (not PICS_S1AP_eNB_IUT) {
log("*** " & __SCOPE__ & ": ERROR: 'PICS_S1AP_eNB_IUT' shall be set to true for executing the TC. ***");
stop;
}
// Test component direct information
f_cf_S1AP_eNB_Up(v_s1ap_enb);
// Start
// synchronize PTC on 1 sychronization points
f_serverSyncNClientsAndStop(1, {c_prDone, c_tbDone, c_poDone});
f_cf_Down();
/**
* @desc Verify that the IUT can successfully manage Reset procedure in case of Abnormal Condition at the E-UTRAN.
* <pre>
* Ensure that the IUT
* on receipt of a RESET
* containing a Cause
* indicating an appropriate cause value
* containing a Reset_Type
* containing a Part_of_S1_interface
* indicating one empty ‘UE-associated_logical_S1-connection’
* sends a RESET_ACKNOWLEDGE
* containing a UE-associated_logical_S1-connection_list.
* </pre>
*
* @see ETSI TS 103 497-2 TP_S1AP_eNB_MNP_03
* @reference ETSI TS 136 413 V13.4.0 Clause 8.7.1.2.2¶1 and 9.1.8.1 and 9.1.8.2
*/
864
865
866
867
868
869
870
871
872
873
874
875
876
877
878
879
880
881
882
883
884
885
886
887
888
889
testcase TC_S1AP_eNB_MNP_03() runs on S1AP system TestAdapter {
// Local variables
var S1AP v_s1ap_enb;
// Test control
if (not PICS_S1AP_eNB_IUT) {
log("*** " & __SCOPE__ & ": ERROR: 'PICS_S1AP_eNB_IUT' shall be set to true for executing the TC. ***");
stop;
}
// Test component direct information
f_cf_S1AP_eNB_Up(v_s1ap_enb);
// Start
v_s1ap_enb.start(f_TC_S1AP_eNB_MNP_03());
// synchronize PTC on 1 sychronization points
f_serverSyncNClientsAndStop(1, {c_prDone, c_tbDone, c_poDone});
f_cf_Down();
} // End of testcase TC_S1AP_eNB_MNP_03
/**
* @desc Verify that the IUT can send an ERROR_INDICATION due to an Error Indication procedure.
* <pre>
* Configuration: CF_S1-MME
* Ensure that the IUT
* to indicate an Error Indication procedure
* sends an ERROR_INDICATION
* (containing a Cause
* or containing a Criticality_Diagnostics).
* </pre>
*
* @see ETSI TS 103 497-2 TP_S1AP_eNB_MNP_04
900
901
902
903
904
905
906
907
908
909
910
911
912
913
914
915
916
917
918
919
920
921
922
923
924
925
926
927
* @reference ETSI TS 136 413 V13.4.0 Clause 8.7.2.2 and 9.1.8.3
*/
testcase TC_S1AP_eNB_MNP_04() runs on S1AP system TestAdapter {
// Local variables
var S1AP v_s1ap_enb;
// Test control
if (not PICS_S1AP_eNB_IUT) {
log("*** " & __SCOPE__ & ": ERROR: 'PICS_S1AP_eNB_IUT' shall be set to true for executing the TC. ***");
stop;
}
// Test component direct information
f_cf_S1AP_eNB_Up(v_s1ap_enb);
// Start
v_s1ap_enb.start(f_TC_S1AP_eNB_MNP_04());
// synchronize PTC on 1 sychronization points
f_serverSyncNClientsAndStop(1, {c_prDone, c_tbDone, c_poDone});
f_cf_Down();
} // End of testcase TC_S1AP_eNB_MNP_04
/**
* @desc Verify that the IUT can send a S1_SETUP_REQUEST to indicate a S1 Setup procedure.
* <pre>
* Configuration: CF_S1-MME
* Ensure that the IUT
* to indicate a S1 Setup procedure
* sends a S1_SETUP_REQUEST
* containing a Global_eNB_ID
* containing a Supported_TAs
* containing a TAC
* containing a Default_Paging_DRX.
* </pre>
*
* @see ETSI TS 103 497-2 TP_S1AP_eNB_MNP_05
* @reference ETSI TS 136 413 V13.4.0 Clause 8.7.3.2¶1 and 9.1.8.4 and 9.1.8.5
*/
testcase TC_S1AP_eNB_MNP_05() runs on S1AP system TestAdapter {
// Local variables
var S1AP v_s1ap_enb;
// Test control
if (not PICS_S1AP_eNB_IUT) {
log("*** " & __SCOPE__ & ": ERROR: 'PICS_S1AP_eNB_IUT' shall be set to true for executing the TC. ***");
stop;
}
// Test component direct information
f_cf_S1AP_eNB_Up(v_s1ap_enb);
// Start
// synchronize PTC on 1 sychronization points
f_serverSyncNClientsAndStop(1, {c_prDone, c_tbDone, c_poDone});
f_cf_Down();
/**
* @desc Verify that the IUT can send an ENB_CONFIGURATION_UPDATE to indicate an eNB Configuration Update procedure.
* <pre>
* Configuration: CF_S1-MME
* Ensure that the IUT
* to indicate an eNB Configuration Update procedure
* sends an ENB_CONFIGURATION_UPDATE
* containing a Global_eNB_ID
* containing a Supported_TAs
* containing a TAC.
* </pre>
*
* @see ETSI TS 103 497-2 TP_S1AP_eNB_MNP_06
979
980
981
982
983
984
985
986
987
988
989
990
991
992
993
994
995
996
997
998
999
1000
1001
1002
1003
1004
1005
1006
1007
* @reference ETSI TS 136 413 V13.4.0 Clause 8.7.4.2¶1 and 9.1.8.7 and 9.1.8.8
*/
testcase TC_S1AP_eNB_MNP_06() runs on S1AP system TestAdapter {
// Local variables
var S1AP v_s1ap_enb;
// Test control
if (not PICS_S1AP_eNB_IUT) {
log("*** " & __SCOPE__ & ": ERROR: 'PICS_S1AP_eNB_IUT' shall be set to true for executing the TC. ***");
stop;
}
// Test component direct information
f_cf_S1AP_eNB_Up(v_s1ap_enb);
// Start
v_s1ap_enb.start(f_TC_S1AP_eNB_MNP_06());
// synchronize PTC on 1 sychronization points
f_serverSyncNClientsAndStop(1, {c_prDone, c_tbDone, c_poDone});
f_cf_Down();
} // End of testcase TC_S1AP_eNB_MNP_06
/**
* @desc Verify that the IUT can successfully process all mandatory IEs in an MME_CONFIGURATION_UPDATE and
* sends an MME_CONFIGURATION_UPDATE_ACKNOWLEDGE due to an MME Configuration Update procedure.
* <pre>
* Configuration: CF_S1-MME
* Ensure that the IUT
* on receipt of an MME_CONFIGURATION_UPDATE
* may containing a Served_GUMMEIs
* may containing a Served_PLMNs
* sends an MME_CONFIGURATION_UPDATE_ACKNOWLEDGE.
* </pre>
*
* @see ETSI TS 103 497-2 TP_S1AP_eNB_MNP_07
1018
1019
1020
1021
1022
1023
1024
1025
1026
1027
1028
1029
1030
1031
1032
1033
1034
1035
1036
1037
1038
1039
1040
1041
1042
1043
1044
1045
1046
* @reference ETSI TS 136 413 V13.4.0 Clause 8.7.5.2¶1 and 9.1.8.10 and 9.1.8.11
*/
testcase TC_S1AP_eNB_MNP_07() runs on S1AP system TestAdapter {
// Local variables
var S1AP v_s1ap_enb;
// Test control
if (not PICS_S1AP_eNB_IUT) {
log("*** " & __SCOPE__ & ": ERROR: 'PICS_S1AP_eNB_IUT' shall be set to true for executing the TC. ***");
stop;
}
// Test component direct information
f_cf_S1AP_eNB_Up(v_s1ap_enb);
// Start
v_s1ap_enb.start(f_TC_S1AP_eNB_MNP_07());
// synchronize PTC on 1 sychronization points
f_serverSyncNClientsAndStop(1, {c_prDone, c_tbDone, c_poDone});
f_cf_Down();
} // End of testcase TC_S1AP_eNB_MNP_07
/**
* @desc Verify that the IUT can successfully process all mandatory IEs in an MME_CONFIGURATION_UPDATE and
* sends an MME CONFIGURATION UPDATE_FAILURE due to an invalid MME Configuration Update procedure.
* <pre>
* Configuration: CF_S1-MME
* Ensure that the IUT
* on receipt of an MME_CONFIGURATION_UPDATE
* containing a Broadcast_PLMNs
* indicating at least one unknown PLMN identity
* sends an MME_CONFIGURATION_UPDATE_FAILURE
* containing a Cause
* indicating an appropriate cause value.
* </pre>
*
* @see ETSI TS 103 497-2 TP_S1AP_eNB_MNP_08
1059
1060
1061
1062
1063
1064
1065
1066
1067
1068
1069
1070
1071
1072
1073
1074
1075
1076
1077
1078
1079
1080
1081
1082
1083
* @reference ETSI TS 136 413 V13.4.0 Clause 8.7.5.3 and 9.1.8.10 and 9.1.8.12
*/
testcase TC_S1AP_eNB_MNP_08() runs on S1AP system TestAdapter {
// Local variables
var S1AP v_s1ap_enb;
// Test control
if (not PICS_S1AP_eNB_IUT) {
log("*** " & __SCOPE__ & ": ERROR: 'PICS_S1AP_eNB_IUT' shall be set to true for executing the TC. ***");
stop;
}
// Test component direct information
f_cf_S1AP_eNB_Up(v_s1ap_enb);
// Start
v_s1ap_enb.start(f_TC_S1AP_eNB_MNP_08());
// synchronize PTC on 1 sychronization points
f_serverSyncNClientsAndStop(1, {c_prDone, c_tbDone, c_poDone});
f_cf_Down();
} // End of testcase TC_S1AP_eNB_MNP_08
} // End of group Management_group
/**
* @desc S1 CDMA 2000 tunnelling group
* @see ETSI TS 103 497-2 Clause 5.2.2.1.8 S1 CDMA 2000 tunnelling group group
*/
group S1_CDMA_2000_tunelling_group {
/**
* @desc Verify that the IUT can send a DOWNLINK_S1_CDMA2000_TUNNELLING.
* <pre>
* Ensure that the IUT
* to indicate a CDMA2000 to be forwarded
* sends an UPLINK_S1_CDMA2000_TUNNELLING
* containing an MME_UE_S1AP_ID
* containing an eNB_UE_S1AP_ID
* containing a CDMA2000_RAT_Type
* containing a CDMA2000_Sector_ID
* containing a CDMA2000_PDU.
* </pre>
*
* @see ETSI TS 103 497-2 TP_S1AP_eNB_STP_01
* @reference ETSI TS 136 413 V13.4.0 Clause 8.8.2.2¶1 and 9.1.9.2 and 9.2.1.23
*/
testcase TC_S1AP_eNB_STP_01() runs on S1AP system TestAdapter {
// Local variables
var S1AP v_s1ap_enb;
// Test control
if (not PICS_S1AP_eNB_IUT) {
log("*** " & __SCOPE__ & ": ERROR: 'PICS_S1AP_eNB_IUT' shall be set to true for executing the TC. ***");
stop;
}
// Test component direct information
f_cf_S1AP_eNB_Up(v_s1ap_enb);
// Start
// synchronize PTC on 1 sychronization points
f_serverSyncNClientsAndStop(1, {c_prDone, c_tbDone, c_poDone});
f_cf_Down();
} // End of group S1_CDMA_2000_tunelling_group
/**
* @desc UE capability info indication group
* @see ETSI TS 103 497-2 Clause 5.2.2.1.9 UE capability info indication group
*/
group UE_capability_info_indication_group {
/**
* @desc Verify that the IUT can send a UE_CAPABILITY_INFO_INDICATION to indicate capability-related information update.
* <pre>
* Ensure that the IUT
* to indicate a capability-related information update
* sends an UE_CAPABILITY_INFO_INDICATION
* containing an MME_UE_S1AP_ID
* containing an eNB_UE_S1AP_ID
* containing a containing a UE_Radio_Capability.
* </pre>
*
* @see ETSI TS 103 497-2 TP_S1AP_eNB_UEC_01
* @reference ETSI TS 136 413 V13.4.0 Clause 8.9.2 and 9.1.10
*/
testcase TC_S1AP_eNB_UEC_01() runs on S1AP system TestAdapter {
// Local variables
var S1AP v_s1ap_enb;
// Test control
if (not PICS_S1AP_eNB_IUT) {
log("*** " & __SCOPE__ & ": ERROR: 'PICS_S1AP_eNB_IUT' shall be set to true for executing the TC. ***");
stop;
}
// Test component direct information
f_cf_S1AP_eNB_Up(v_s1ap_enb);
// Start
// synchronize PTC on 1 sychronization points
f_serverSyncNClientsAndStop(1, {c_prDone, c_tbDone, c_poDone});
f_cf_Down();
} // End of group UE_capability_info_indication_group
/**
* @desc Trace Procedures group
* @see ETSI TS 103 497-2 Clause 5.2.2.1.10 Trace group
*/
group Trace_group {
/**
* @desc Verify that the IUT can successfully send a TRACE_FAILURE_INDICATION on TRACE_START.
* <pre>
* Ensure that the IUT
* on receipt of a TRACE_START
* containing an MME_UE_S1AP_ID
* containing an eNB_UE_S1AP_ID
* containing a Trace_Activation
* containing an E-UTRAN_Trace_ID
* containing a Interfaces_To_Trace
* indicating value ‘S1-MME’
* containing a Trace_depth
* indicating value ‘maximum’
* containing a Trace_Collection_Entity_IP_Address
* not containing an MDT_Configuration
* sends TRACE_FAILURE_INDICATION
* containing an MME_UE_S1AP_ID
* containing an eNB_UE_S1AP_ID
* containing an E-UTRAN_Trace_ID
* containing a Cause
* indicating an appropriate cause value.
* </pre>
*
* @see ETSI TS 103 497-2 TP_S1AP_eNB_TRP_01
* @reference ETSI TS 136 413 V13.4.0 Clause 8.10.1.2-8 and 8.10.2.2 and 9.1.11.1 and 9.1.11.2
*/
testcase TC_S1AP_eNB_TRP_01() runs on S1AP system TestAdapter {
// Local variables
var S1AP v_s1ap_enb;
// Test control
if (not PICS_S1AP_eNB_IUT) {
log("*** " & __SCOPE__ & ": ERROR: 'PICS_S1AP_eNB_IUT' shall be set to true for executing the TC. ***");
stop;
}
// Test component direct information
f_cf_S1AP_eNB_Up(v_s1ap_enb);
// Start
// synchronize PTC on 1 sychronization points
f_serverSyncNClientsAndStop(1, {c_prDone, c_tbDone, c_poDone});
f_cf_Down();
/**
* @desc Verify that the IUT can successfully send a TRACE_FAILURE_INDICATION on DEACTIVATE_TRACE.
* <pre>
* Ensure that the IUT
* on receipt of a DEACTIVATE_TRACE
* containing an MME_UE_S1AP_ID
* containing an eNB_UE_S1AP_ID
* containing a Trace_Activation
* containing an E-UTRAN_Trace_ID
* sends TRACE_FAILURE_INDICATION
* containing an MME_UE_S1AP_ID
* containing an eNB_UE_S1AP_ID
* containing an E-UTRAN_Trace_ID
* containing a Cause
* indicating an appropriate cause value.
* </pre>
*
* @see ETSI TS 103 497-2 TP_S1AP_eNB_TRP_02
* @reference ETSI TS 136 413 V13.4.0 Clause 8.10.3.2-3 and 8.10.2.2 and 9.1.11.3 and 9.1.11.2
testcase TC_S1AP_eNB_TRP_02() runs on S1AP system TestAdapter {
// Local variables
var S1AP v_s1ap_enb;
// Test control
if (not PICS_S1AP_eNB_IUT) {
log("*** " & __SCOPE__ & ": ERROR: 'PICS_S1AP_eNB_IUT' shall be set to true for executing the TC. ***");
stop;
}
// Test component direct information
f_cf_S1AP_eNB_Up(v_s1ap_enb);
// Start
// synchronize PTC on 1 sychronization points
f_serverSyncNClientsAndStop(1, {c_prDone, c_tbDone, c_poDone});
f_cf_Down();
/**
* @desc Verify that the IUT can send a CELL_TRAFFIC_TRACE when the conditions required for tracing are met.
* <pre>
* Ensure that the IUT
* to indicate the conditions required for tracing are met
* sends CELL_TRAFFIC_TRACE
* containing an MME_UE_S1AP_ID
* containing an eNB_UE_S1AP_ID
* containing an E-UTRAN_Trace_ID
* containing an E-UTRAN_CGI
* containing a PLMN_Identity
* containing a Cell_Identity
* containing a Trace_Collection_Entity_IP_Address.
* </pre>
*
* @see ETSI TS 103 497-2 TP_S1AP_eNB_TRP_03
* @reference ETSI TS 136 413 V13.4.0 Clause 8.10.4.2 and 9.1.18
*/
testcase TC_S1AP_eNB_TRP_03() runs on S1AP system TestAdapter {
// Local variables
var S1AP v_s1ap_enb;
// Test control
if (not PICS_S1AP_eNB_IUT) {
log("*** " & __SCOPE__ & ": ERROR: 'PICS_S1AP_eNB_IUT' shall be set to true for executing the TC. ***");
stop;
}
// Test component direct information
f_cf_S1AP_eNB_Up(v_s1ap_enb);
// Start
// synchronize PTC on 1 sychronization points
f_serverSyncNClientsAndStop(1, {c_prDone, c_tbDone, c_poDone});
f_cf_Down();
* @desc Location Reporting Procedures group
* @see ETSI TS 103 497-2 Clause 5.2.2.1.11 Location reporting group
* @desc Verify that the IUT can process all mandatory IEs in a LOCATION_REPORTING_CONTROL containing Event Type IE indicating Directly and sends a LOCATION_REPORT.
1340
1341
1342
1343
1344
1345
1346
1347
1348
1349
1350
1351
1352
1353
1354
1355
1356
1357
1358
1359
1360
1361
1362
* Ensure that the IUT
* on receipt of a LOCATION_REPORTING_CONTROL
* containing an MME_UE_S1AP_ID
* containing an eNB_UE_S1AP_ID
* containing a Request_Type
* containing an Event_Type
* indicating Directly
* containing a Report_Area
* indicating ECGI
* sends LOCATION_REPORT
* containing an MME_UE_S1AP_ID
* containing an eNB_UE_S1AP_ID
* containing an E-UTRAN_CGI
* containing a PLMN_Identity
* containing a Cell_Identity
* containing a TAI
* containing a PLMN_Identity
* containing a TAC
* containing a Request_Type
* containing a Event_Type
* containing a Report_Area.
* </pre>
*
* @see ETSI TS 103 497-2 TP_S1AP_eNB_LRP_01
* @reference ETSI TS 136 413 V13.4.0 Clause 8.11.1.2-2(1st dashed line) and 9.1.12.1 and 9.1.12.3 and 9.2.1.16,34,38
*/
testcase TC_S1AP_eNB_LRP_01() runs on S1AP system TestAdapter {
// Local variables
var S1AP v_s1ap_enb;
// Test control
if (not PICS_S1AP_eNB_IUT) {
log("*** " & __SCOPE__ & ": ERROR: 'PICS_S1AP_eNB_IUT' shall be set to true for executing the TC. ***");
stop;
}
// Test component direct information
f_cf_S1AP_eNB_Up(v_s1ap_enb);
// Start
// synchronize PTC on 1 sychronization points
f_serverSyncNClientsAndStop(1, {c_prDone, c_tbDone, c_poDone});
f_cf_Down();
* @desc Verify that the IUT can process all mandatory IEs in a LOCATION_REPORTING_CONTROL containing Event Type IE indicating Change of service cell and sends a LOCATION_REPORT.
1394
1395
1396
1397
1398
1399
1400
1401
1402
1403
1404
1405
1406
1407
1408
1409
1410
1411
1412
1413
1414
1415
1416
1417
* Ensure that the IUT
* on receipt of a LOCATION_REPORTING_CONTROL
* containing an MME_UE_S1AP_ID
* containing an eNB_UE_S1AP_ID
* containing a Request_Type
* containing an Event_Type
* indicating change_of_service_cell
* containing a Report_Area
* indicating ECGI
* when UE changes to new cell
* sends LOCATION_REPORT
* containing an MME_UE_S1AP_ID
* containing an eNB_UE_S1AP_ID
* containing an E-UTRAN_CGI
* containing a PLMN_Identity
* containing a Cell_Identity
* containing a TAI
* containing a PLMN_Identity
* containing a TAC
* containing a Request_Type
* containing a Event_Type
* containing a Report_Area.
* </pre>
*
* @see ETSI TS 103 497-2 TP_S1AP_eNB_LRP_02
* @reference ETSI TS 136 413 V13.4.0 Clause 8.11.1.2-2(1st dashed line) and 9.1.12.1 and 9.1.12.3 and 9.2.1.16,34,38
*/
testcase TC_S1AP_eNB_LRP_02() runs on S1AP system TestAdapter {
// Local variables
var S1AP v_s1ap_enb;
// Test control
if (not PICS_S1AP_eNB_IUT) {
log("*** " & __SCOPE__ & ": ERROR: 'PICS_S1AP_eNB_IUT' shall be set to true for executing the TC. ***");
stop;
}
// Test component direct information
f_cf_S1AP_eNB_Up(v_s1ap_enb);
// Start
// synchronize PTC on 1 sychronization points
f_serverSyncNClientsAndStop(1, {c_prDone, c_tbDone, c_poDone});
f_cf_Down();
* @desc Verify that the IUT can process all mandatory IEs in a LOCATION_REPORTING_CONTROL containing Event Type IE indicating Stop change of service cell and sends a LOCATION_REPORT.
1449
1450
1451
1452
1453
1454
1455
1456
1457
1458
1459
1460
1461
1462
1463
1464
1465
1466
1467
1468
1469
1470
1471
1472
* Ensure that the IUT
* on receipt of a LOCATION_REPORTING_CONTROL
* containing an MME_UE_S1AP_ID
* containing an eNB_UE_S1AP_ID
* containing a Request_Type
* containing an Event_Type
* indicating stop_change_of_service_cell
* containing a Report_Area
* indicating ECGI
* when UE changes to new cell
* sends LOCATION_REPORT
* containing an MME_UE_S1AP_ID
* containing an eNB_UE_S1AP_ID
* containing an E-UTRAN_CGI
* containing a PLMN_Identity
* containing a Cell_Identity
* containing a TAI
* containing a PLMN_Identity
* containing a TAC
* containing a Request_Type
* containing a Event_Type
* containing a Report_Area.
* </pre>
*
* @see ETSI TS 103 497-2 TP_S1AP_eNB_LRP_03
* @reference ETSI TS 136 413 V13.4.0 Clause 8.11.1.2-2(1st dashed line) and 9.1.12.1 and 9.1.12.3 and 9.2.1.16,34,38
*/
testcase TC_S1AP_eNB_LRP_03() runs on S1AP system TestAdapter {
// Local variables
var S1AP v_s1ap_enb;
// Test control
if (not PICS_S1AP_eNB_IUT) {
log("*** " & __SCOPE__ & ": ERROR: 'PICS_S1AP_eNB_IUT' shall be set to true for executing the TC. ***");
stop;
}
// Test component direct information
f_cf_S1AP_eNB_Up(v_s1ap_enb);
// Start
// synchronize PTC on 1 sychronization points
f_serverSyncNClientsAndStop(1, {c_prDone, c_tbDone, c_poDone});
f_cf_Down();
/**
* @desc Verify that the IUT can send a LOCATION REPORT_FAILURE_INDICATION.
* <pre>
* Ensure that the IUT
* on receipt of a LOCATION_REPORTING_CONTROL
* containing an MME_UE_S1AP_ID
* containing an eNB_UE_S1AP_ID
* containing a Request_Type
* containing an Event_Type
* containing a Report_Area
* sends LOCATION REPORT_FAILURE_INDICATION
* containing an MME_UE_S1AP_ID
* containing an eNB_UE_S1AP_ID
* containing a Cause
* indicating an appropriate cause value.
* </pre>
*
* @see ETSI TS 103 497-2 TP_S1AP_eNB_LRP_04
* @reference ETSI TS 136 413 V13.4.0 Clause 8.11.2.2-1 and 9.1.12.2
*/
testcase TC_S1AP_eNB_LRP_04() runs on S1AP system TestAdapter {
// Local variables
var S1AP v_s1ap_enb;
// Test control
if (not PICS_S1AP_eNB_IUT) {
log("*** " & __SCOPE__ & ": ERROR: 'PICS_S1AP_eNB_IUT' shall be set to true for executing the TC. ***");
stop;
}
// Test component direct information
f_cf_S1AP_eNB_Up(v_s1ap_enb);
// Start
// synchronize PTC on 1 sychronization points
f_serverSyncNClientsAndStop(1, {c_prDone, c_tbDone, c_poDone});
f_cf_Down();
} // End of group Location_reporting_group
/**
* @desc Warning message transmission group
* @see ETSI TS 103 497-2 Clause 5.2.2.1.12 Warning message transmission group
*/
group Warning_message_transmission_group {
/**
* @desc Verify that the IUT can successfully process all mandatory IEs in a WRITE-REPLACE_WARNING_REQUEST received and sends a WRITE-REPLACE_WARNING_RESPONSE.
* Ensure that the IUT
* on receipt of an WRITE-REPLACE_WARNING_REQUEST
* containing a Message_Identifier
* containing a Serial_Number
* containing a Repetition Period
* containing an Number_of_Broadcasts_Requested
* sends an WRITE-REPLACE_WARNING_RESPONSE
* containing a Serial_Number.
* </pre>
*
* @see ETSI TS 103 497-2 TP_S1AP_eNB_WTP_01
* @reference ETSI TS 136 413 V13.4.0 Clause 8.12.1.2-1 and 9.1.13.1 and 9.1.13.2
*/
testcase TC_S1AP_eNB_WTP_01() runs on S1AP system TestAdapter {
// Local variables
var S1AP v_s1ap_enb;
// Test control
if (not PICS_S1AP_eNB_IUT) {
log("*** " & __SCOPE__ & ": ERROR: 'PICS_S1AP_eNB_IUT' shall be set to true for executing the TC. ***");
stop;
}
// Test component direct information
f_cf_S1AP_eNB_Up(v_s1ap_enb);
// Start
// synchronize PTC on 1 sychronization points
f_serverSyncNClientsAndStop(1, {c_prDone, c_tbDone, c_poDone});
f_cf_Down();
* @desc Verify that the IUT can successfully process all mandatory IEs in an KILL_REQUEST received and sends a KILL_RESPONSE.
* Ensure that the IUT
* on receipt of a KILL_REQUEST
* containing a Message_Identifier
* containing a Serial_Number
* sends sends a KILL_RESPONSE
* containing a Message_Identifier
* containing a Serial_Number.
* </pre>
*
* @see ETSI TS 103 497-2 TP_S1AP_eNB_WTP_02
* @reference ETSI TS 136 413 V13.4.0 Clause 8.12.2.2-1,3 and 9.1.13.3 and 9.1.13.4
*/
testcase TC_S1AP_eNB_WTP_02() runs on S1AP system TestAdapter {
// Local variables
var S1AP v_s1ap_enb;
// Test control
if (not PICS_S1AP_eNB_IUT) {
log("*** " & __SCOPE__ & ": ERROR: 'PICS_S1AP_eNB_IUT' shall be set to true for executing the TC. ***");
stop;
}
// Test component direct information
f_cf_S1AP_eNB_Up(v_s1ap_enb);
// Start
// synchronize PTC on 1 sychronization points
f_serverSyncNClientsAndStop(1, {c_prDone, c_tbDone, c_poDone});
f_cf_Down();
/**
* @desc Verify that the IUT can send a PWS_RESTART_INDICATION to indicate a PWS Restart Indication procedure.
* <pre>
* Ensure that the IUT
* to indicate a PWS Restart Indication procedure
* sends a PWS_RESTART_INDICATION
* containing an E-CGI_List_for_Restart
* indicating a valid list of E-CGI
* containing a TAI_List_for_Restart
* indicating a valid list of eNB identifier
* containing an Emergency_Area_ID_List_for_Restart
* indicating an empty list.
* </pre>
*
* @see ETSI TS 103 497-2 TP_S1AP_eNB_WTP_03
* @reference ETSI TS 136 413 V13.4.0 Clause 8.12.3.2 and 9.1.13.5
*/
testcase TC_S1AP_eNB_WTP_03() runs on S1AP system TestAdapter {
// Local variables
var S1AP v_s1ap_enb;
// Test control
if (not PICS_S1AP_eNB_IUT) {
log("*** " & __SCOPE__ & ": ERROR: 'PICS_S1AP_eNB_IUT' shall be set to true for executing the TC. ***");
stop;
}
// Test component direct information
f_cf_S1AP_eNB_Up(v_s1ap_enb);
// Start
// synchronize PTC on 1 sychronization points
f_serverSyncNClientsAndStop(1, {c_prDone, c_tbDone, c_poDone});
f_cf_Down();
/**
* @desc Verify that the IUT can send a PWS_FAILURE_INDICATION to indicate PWS Failure Indication procedure.
* <pre>
* Ensure that the IUT
* to indicate a PWS Failure Indication procedure
* sends a PWS_FAILURE_INDICATION
* containing an PWS failed E-CGI List
* indicating a valid list of E-CGI
* @see ETSI TS 103 497-2 TP_S1AP_eNB_WTP_04
* @reference ETSI TS 136 413 V13.4.0 Clause 8.12.4.2 and 9.1.13.6
*/
testcase TC_S1AP_eNB_WTP_04() runs on S1AP system TestAdapter {
// Local variables
var S1AP v_s1ap_enb;
// Test control
if (not PICS_S1AP_eNB_IUT) {
log("*** " & __SCOPE__ & ": ERROR: 'PICS_S1AP_eNB_IUT' shall be set to true for executing the TC. ***");
stop;
}
// Test component direct information
f_cf_S1AP_eNB_Up(v_s1ap_enb);
// Start
// synchronize PTC on 1 sychronization points
f_serverSyncNClientsAndStop(1, {c_prDone, c_tbDone, c_poDone});
f_cf_Down();
} // End of group Warning_message_transmission_group
/**
* @desc eNB direct information transfer group
* @see ETSI TS 103 497-2 Clause 5.2.2.1.13 eNB direct information transfer group
*/
group ENB_direct_information_transfer_group {
/**
* @desc Verify that the IUT can send an eNB_DIRECT_INFORMATION_TRANSFER to indicate an eNB Direct Information Transfer procedure.
* <pre>
* Ensure that the IUT
* to indicate an eNB direct information Transfer procedure,
* sends an eNB_DIRECT_INFORMATION_TRANSFER
* containing an Inter-system_Information_Transfer_Type
* containing a RIM
* containing a RIM_Transfer
* containing a RIM_Information
* containing a RIM_Routing_Address.
* </pre>
*
* @see ETSI TS 103 497-2 TP_S1AP_eNB_EIT_01
* @reference ETSI TS 136 413 V13.4.0 Clause 8.13.2.1 and 9.1.14 and 9.2.3.23
*/
testcase TC_S1AP_eNB_EIT_01() runs on S1AP system TestAdapter {
// Local variables
var S1AP v_s1ap_enb;
// Test control
if (not PICS_S1AP_eNB_IUT) {
log("*** " & __SCOPE__ & ": ERROR: 'PICS_S1AP_eNB_IUT' shall be set to true for executing the TC. ***");
stop;
}
// Test component direct information
f_cf_S1AP_eNB_Up(v_s1ap_enb);
// Start
// synchronize PTC on 1 sychronization points
f_serverSyncNClientsAndStop(1, {c_prDone, c_tbDone, c_poDone});
f_cf_Down();
} // End of group ENB_direct_information_transfer_group
/**
* @desc eNB configuration transfer group
* @see ETSI TS 103 497-2 Clause 5.2.2.1.15 eNB configuration transfer group
*/
group ENB_configuration_transfer_group {
/**
* @desc Verify that the IUT can send an eNB_CONFIGURATION_TRANSFER to indicate an eNB Configuration Transfer procedure.
* <pre>
* Configuration: CF_S1-MME
* Ensure that the IUT
* to indicate an eNB Configuration Transfer procedure,
* sends an eNB_CONFIGURATION_TRANSFER
* containing a SON_Configuration_Transfer
* containing a Target_eNB-ID
* containing a Source_eNB-ID
* containing a SON_Information.
* containing a SON_Information_Request
* indicating X2TNL_Configuration_Info
* containing an X2_TNL_Configuration_Info.
* </pre>
*
* @see ETSI TS 103 497-2 TP_S1AP_eNB_ECT_01
* @reference ETSI TS 136 413 V13.4.0 Clause 8.15.2.1 and 9.1.16
*/
testcase TC_S1AP_eNB_ECT_01() runs on S1AP system TestAdapter {
// Local variables
var S1AP v_s1ap_enb;
// Test control
if (not PICS_S1AP_eNB_IUT) {
log("*** " & __SCOPE__ & ": ERROR: 'PICS_S1AP_eNB_IUT' shall be set to true for executing the TC. ***");
stop;
}
// Test component configuration
f_cf_S1AP_eNB_Up(v_s1ap_enb);
// Start
// synchronize PTC on 1 sychronization points
f_serverSyncNClientsAndStop(1, {c_prDone, c_tbDone, c_poDone});
f_cf_Down();
} // End of group ENB_configuration_transfer_group
/**
* @desc LPPa transport group
* @see ETSI TS 103 497-2 Clause 5.2.2.1.17 LPPa transport group
*/
group LPPa_transport_group {
/**
* @desc Verify that the IUT can send a UPLINK_UE_ASSOCIATED_LPPA_TRANSPORT to indicate a LPPa Transport procedure
* using a UE associated signalling.
* <pre>
* Configuration: CF_S1-MME
* Ensure that the IUT
* to indicate a LPPa Transport procedure using a UE associated signalling,
* sends a UPLINK_UE_ASSOCIATED_LPPA_TRANSPORT
* containing an MME_UE_S1AP_ID
* containing an eNB_UE_S1AP_ID
* containing a Routing_ID
* indicating a valid routing identifier value
* containing an LPPa-PDU.
* </pre>
*
* @see ETSI TS 103 497-2 TP_S1AP_eNB_LPP_01
* @reference ETSI TS 136 413 V13.4.0 Clause 8.17.2.2 and 9.1.19.2
*/
testcase TC_S1AP_eNB_LPP_01() runs on S1AP system TestAdapter {
// Local variables
var S1AP v_s1ap_enb;
// Test control
if (not PICS_S1AP_eNB_IUT) {
log("*** " & __SCOPE__ & ": ERROR: 'PICS_S1AP_eNB_IUT' shall be set to true for executing the TC. ***");
stop;
}
// Test component configuration
f_cf_S1AP_eNB_Up(v_s1ap_enb);
// Start
// synchronize PTC on 1 sychronization points
f_serverSyncNClientsAndStop(1, {c_prDone, c_tbDone, c_poDone});
f_cf_Down();
/**
* @desc Verify that the IUT can send a UPLINK_UE_ASSOCIATED_LPPA_TRANSPORT to indicate a LPPa Transport procedure
* using a Non-UE associated signalling.
* <pre>
* Configuration: CF_S1-MME
* Ensure that the IUT
* to indicate a LPPa Transport procedure using a UE associated signalling,
* sends a UPLINK_UE_ASSOCIATED_LPPA_TRANSPORT
* containing an MME_UE_S1AP_ID
* containing an eNB_UE_S1AP_ID
* containing a Routing_ID
* indicating a valid routing identifier value
* containing an LPPa-PDU.
* </pre>
*
* @see ETSI TS 103 497-2 TP_S1AP_eNB_LPP_02
* @reference ETSI TS 136 413 V13.4.0 Clause 8.17.2.4 and 9.1.19.4
*/
testcase TC_S1AP_eNB_LPP_02() runs on S1AP system TestAdapter {
// Local variables
var S1AP v_s1ap_enb;
// Test control
if (not PICS_S1AP_eNB_IUT) {
log("*** " & __SCOPE__ & ": ERROR: 'PICS_S1AP_eNB_IUT' shall be set to true for executing the TC. ***");
stop;
}
// Test component configuration
f_cf_S1AP_eNB_Up(v_s1ap_enb);
// Start
// synchronize PTC on 1 sychronization points
f_serverSyncNClientsAndStop(1, {c_prDone, c_tbDone, c_poDone});
f_cf_Down();
} // End of group LPPa_transport_group
/**
* @desc Unknown, Unforseen and Erroneous Protocol Data
* @see ETSI TS 103 497-2 Clause 5.2.2.2.18 Unknown, Unforseen and Erroneous Protocol Data
*/
group Unknown_unforseen_errorneous_group {
/**
* @desc Verify that the IUT rejects the procedure using Error Indication Procedure if message contains different types of received
* criticality information of the Procedure Code IE and include Procedure Code IE, Triggering Message IE and
* Procedure Criticality IE in the Criticality Diagnostics IE within ERROR_INDICATION.
* <pre>
1921
1922
1923
1924
1925
1926
1927
1928
1929
1930
1931
1932
1933
1934
1935
1936
1937
1938
1939
1940
1941
1942
1943
1944
1945
1946
1947
1948
1949
1950
1951
1952
1953
1954
1955
1956
1957
1958
1959
1960
1961
1962
1963
1964
1965
1966
1967
1968
1969
1970
1971
1972
1973
* Configuration: CF_S1-MME
* Ensure that the IUT
* on receipt of an INITIAL_CONTEXT_SETUP_REQUEST,
* with Criticality set to value from the Table 4
* containing an MME UE_S1AP_ID
* containing an eNB_UE_S1AP_ID
* containing a UE_Aggregate_Maximum_Bit_Rate
* containing an E-RAB_to_be_Setup_List
* containing an E-RAB_to_be_Setup Item 1
* containing an E-RAB_ID
* containing an E-RAB_Level_QoS_Parameters
* containing a Transport_Layer_Address
* containing a GTP-TEID
* containing a NAS-PDU
* containing a UE_Security_Capabilities
* containing an Encription_Algorithms
* indicating not supported algoithm
* containing an Integrity_Protection_Algorithms
* containing a Security_Key
* sends an ERROR_INDICATION
* containing a Criticality_Diagnostics
* containing a Procedure_Code
* containing a Triggering_Message
* containing a Procedure_Criticality.
* </pre>
*
* @see ETSI TS 103 497-2 TP_S1AP_ENB_ERR_01
* @reference ETSI TS 136 413 V13.4.0 Clause 10.3.4.1¶8
*/
testcase TC_S1AP_ENB_ERR_01() runs on S1AP system TestAdapter {
// Local variables
var S1AP v_s1ap_enb;
// Test control
if (not (PICS_S1AP_eNB_IUT and PICS_S1AP_eNB_INITIATION_ERROR_IND_ABSTRACT_SYNTAX_PROCEDURE)) {
log("*** " & __SCOPE__ & ": ERROR: 'PICS_S1AP_eNB_IUT and PICS_S1AP_eNB_INITIATION_ERROR_IND_ABSTRACT_SYNTAX_PROCEDURE' shall be set to true for executing the TC. ***");
stop;
}
// Test component configuration
f_cf_S1AP_eNB_Up(v_s1ap_enb);
// Start
v_s1ap_enb.start(f_TC_S1AP_ENB_ERR_01());
// synchronize PTC on 1 sychronization points
f_serverSyncNClientsAndStop(1, {c_prDone, c_tbDone, c_poDone});
f_cf_Down();
} // End of testcase TC_S1AP_ENB_ERR_01
/**
* @desc Verify that the IUT rejects the procedure if message contains not comprehended IEs/IE groups marked with
* ‘Reject IE’ or ‘Ignore IE and Notify Sender’ and include Information Element Criticality Diagnostics IE in
* the Criticality Diagnostics IE for each reported IEs/IE groups within response message for this procedure.
1979
1980
1981
1982
1983
1984
1985
1986
1987
1988
1989
1990
1991
1992
1993
1994
1995
1996
1997
1998
1999
2000
2001
2002
2003
2004
2005
2006
2007
2008
2009
2010
2011
2012
2013
2014
2015
2016
2017
2018
2019
2020
2021
2022
2023
2024
2025
2026
2027
2028
2029
2030
2031
2032
2033
2034
2035
2036
2037
2038
2039
2040
2041
2042
2043
* Configuration: CF_S1-MME
* Ensure that the IUT
* on receipt of an INITIAL_CONTEXT_SETUP_REQUEST,
* with Criticality set to value from the Table 4
* containing an MME UE_S1AP_ID
* containing an eNB_UE_S1AP_ID
* containing an Unknown_ID
* containing Criticality
* indicating Reject or Ignore and Notify Sender
* containing a UE_Aggregate_Maximum_Bit_Rate
* containing an E-RAB_to_be_Setup_List
* containing an E-RAB_to_be_Setup Item 1
* containing an E-RAB_ID
* containing an E-RAB_Level_QoS_Parameters
* containing a Transport_Layer_Address
* containing a GTP-TEID
* containing a NAS-PDU
* containing a UE_Security_Capabilities
* containing an Encription_Algorithms
* indicating not supported algoithm
* containing an Integrity_Protection_Algorithms
* containing a Security_Key
* sends an an INITIAL_CONTEXT_SETUP_FAILURE
* containing an MME_UE_S1AP_ID
* containing an eNB_UE_S1AP_ID
* containing a Cause
* indicating appropriate Protocol Cause
* containing a Criticality_Diagnostics
* containing an Information Element Criticality_Diagnostics
* containing an IE_Criticality
* containing an IE_ID
* containing an IE_Type_of_Error.
* </pre>
*
* @see ETSI TS 103 497-2 TP_S1AP_ENB_ERR_02
* @reference ETSI TS 136 413 V13.4.0 Clause 10.3.4.2¶3(1st dashed line) and 13
*/
testcase TC_S1AP_ENB_ERR_02() runs on S1AP system TestAdapter {
// Local variables
var S1AP v_s1ap_enb;
// Test control
if (not (PICS_S1AP_eNB_IUT and PICS_S1AP_eNB_INITIATION_ERROR_IND_ABSTRACT_SYNTAX_PROCEDURE)) {
log("*** " & __SCOPE__ & ": ERROR: 'PICS_S1AP_eNB_IUT and PICS_S1AP_eNB_INITIATION_ERROR_IND_ABSTRACT_SYNTAX_PROCEDURE' shall be set to true for executing the TC. ***");
stop;
}
// Test component configuration
f_cf_S1AP_eNB_Up(v_s1ap_enb);
// Start
v_s1ap_enb.start(f_TC_S1AP_ENB_ERR_02());
// synchronize PTC on 1 sychronization points
f_serverSyncNClientsAndStop(1, {c_prDone, c_tbDone, c_poDone});
f_cf_Down();
} // End of testcase TC_S1AP_ENB_ERR_02
/**
* @desc Verify that the IUT rejects the procedure using Error Indication Procedure if message contains different types of received
* criticality information of the Procedure Code IE and include Procedure Code IE, Triggering Message IE and
* Procedure Criticality IE in the Criticality Diagnostics IE within ERROR_INDICATION.
* <pre>
2045
2046
2047
2048
2049
2050
2051
2052
2053
2054
2055
2056
2057
2058
2059
2060
2061
2062
2063
2064
2065
2066
2067
2068
2069
2070
2071
2072
2073
2074
2075
2076
2077
2078
2079
2080
2081
2082
2083
2084
2085
2086
2087
2088
2089
2090
2091
2092
2093
2094
2095
2096
2097
2098
2099
2100
2101
2102
2103
2104
2105
2106
2107
2108
* Configuration: CF_S1-MME
* Ensure that the IUT
* on receipt of an INITIAL_CONTEXT_SETUP_REQUEST,
* with Criticality set to value from the Table 4
* containing an MME UE_S1AP_ID
* containing an eNB_UE_S1AP_ID
* containing an Unknown_ID
* containing Criticality
* indicating Reject or Ignore and Notify Sender
* containing a UE_Aggregate_Maximum_Bit_Rate
* containing an E-RAB_to_be_Setup_List
* containing an E-RAB_to_be_Setup Item 1
* containing an E-RAB_ID
* containing an E-RAB_Level_QoS_Parameters
* containing a Transport_Layer_Address
* containing a GTP-TEID
* containing a NAS-PDU
* containing a UE_Security_Capabilities
* containing an Encription_Algorithms
* indicating not supported algoithm
* containing an Integrity_Protection_Algorithms
* containing a Security_Key
* sends an ERROR_INDICATION
* containing a Criticality_Diagnostics
* containing a Procedure_Code
* containing a Triggering_Message
* containing a Procedure_Criticality
* containing an Information Element Criticality_Diagnostics
* containing an IE_Criticality
* containing an IE_ID
* containing an IE_Type_of_Error.
* </pre>
*
* @see ETSI TS 103 497-2 TP_S1AP_ENB_ERR_03
* @reference ETSI TS 136 413 V13.4.0 Clause 10.3.4.2¶4(2nd dashed line) and 14
*/
testcase TC_S1AP_ENB_ERR_03() runs on S1AP system TestAdapter {
// Local variables
var S1AP v_s1ap_enb;
// Test control
if (not (PICS_S1AP_eNB_IUT and PICS_S1AP_eNB_INITIATION_ERROR_IND_ABSTRACT_SYNTAX_PROCEDURE)) {
log("*** " & __SCOPE__ & ": ERROR: 'PICS_S1AP_eNB_IUT and PICS_S1AP_eNB_INITIATION_ERROR_IND_ABSTRACT_SYNTAX_PROCEDURE' shall be set to true for executing the TC. ***");
stop;
}
// Test component configuration
f_cf_S1AP_eNB_Up(v_s1ap_enb);
// Start
v_s1ap_enb.start(f_TC_S1AP_ENB_ERR_03());
// synchronize PTC on 1 sychronization points
f_serverSyncNClientsAndStop(1, {c_prDone, c_tbDone, c_poDone});
f_cf_Down();
} // End of testcase TC_S1AP_ENB_ERR_03
/**
* @desc Verify that the IUT rejects the procedure if message not contains mandatory IEs/IE groups and
* include Information Element Criticality Diagnostics IE in the Criticality Diagnostics IE for each
* reported IEs/IE groups within response message for this procedure.
* <pre>
2110
2111
2112
2113
2114
2115
2116
2117
2118
2119
2120
2121
2122
2123
2124
2125
2126
2127
2128
2129
2130
2131
2132
2133
2134
2135
2136
2137
2138
2139
2140
2141
2142
2143
2144
2145
2146
2147
2148
2149
2150
2151
2152
2153
2154
2155
2156
2157
2158
2159
2160
2161
2162
2163
2164
2165
2166
2167
2168
2169
2170
2171
2172
2173
* Configuration: CF_S1-MME
* Ensure that the IUT
* on receipt of an INITIAL_CONTEXT_SETUP_REQUEST,
* with Criticality set to value from the Table 4
* containing an MME UE_S1AP_ID
* not containing an eNB_UE_S1AP_ID
* containing an Unknown_ID
* containing Criticality
* indicating Reject or Ignore and Notify Sender
* containing a UE_Aggregate_Maximum_Bit_Rate
* containing an E-RAB_to_be_Setup_List
* containing an E-RAB_to_be_Setup Item 1
* containing an E-RAB_ID
* containing an E-RAB_Level_QoS_Parameters
* containing a Transport_Layer_Address
* containing a GTP-TEID
* containing a NAS-PDU
* containing a UE_Security_Capabilities
* containing an Encription_Algorithms
* indicating not supported algoithm
* containing an Integrity_Protection_Algorithms
* containing a Security_Key
* sends an ERROR_INDICATION
* containing a Criticality_Diagnostics
* containing a Procedure_Code
* containing a Triggering_Message
* containing a Procedure_Criticality
* containing an Information Element Criticality_Diagnostics
* containing an IE_Criticality
* containing an IE_ID
* containing an IE_Type_of_Error.
* </pre>
*
* @see ETSI TS 103 497-2 TP_S1AP_ENB_ERR_04
* @reference ETSI TS 136 413 V13.4.0 Clause 10.3.5¶3(1st dashed line) and 13
*/
testcase TC_S1AP_ENB_ERR_04() runs on S1AP system TestAdapter {
// Local variables
var S1AP v_s1ap_enb;
// Test control
if (not (PICS_S1AP_eNB_IUT and PICS_S1AP_eNB_INITIATION_ERROR_IND_ABSTRACT_SYNTAX_PROCEDURE)) {
log("*** " & __SCOPE__ & ": ERROR: 'PICS_S1AP_eNB_IUT and PICS_S1AP_eNB_INITIATION_ERROR_IND_ABSTRACT_SYNTAX_PROCEDURE' shall be set to true for executing the TC. ***");
stop;
}
// Test component configuration
f_cf_S1AP_eNB_Up(v_s1ap_enb);
// Start
v_s1ap_enb.start(f_TC_S1AP_ENB_ERR_04());
// synchronize PTC on 1 sychronization points
f_serverSyncNClientsAndStop(1, {c_prDone, c_tbDone, c_poDone});
f_cf_Down();
} // End of testcase TC_S1AP_ENB_ERR_04
/**
* @desc Verify that the IUT rejects the procedure using Error Indication Procedure if message not contains mandatory IEs/IE groups and
* include Procedure Code IE, Triggering Message IE and Procedure Criticality IE and Information Element Criticality Diagnostics IE
* in the Criticality Diagnostics IE for each reported IEs/IE groups within ERROR_INDICATION.
* <pre>
2175
2176
2177
2178
2179
2180
2181
2182
2183
2184
2185
2186
2187
2188
2189
2190
2191
2192
2193
2194
2195
2196
2197
2198
2199
2200
2201
2202
2203
2204
2205
2206
2207
2208
2209
2210
2211
2212
2213
2214
2215
2216
2217
2218
2219
2220
2221
2222
2223
2224
2225
2226
2227
2228
2229
2230
* Configuration: CF_S1-MME
* Ensure that the IUT
* on receipt of an E-RAB_SETUP_REQUEST,
* containing an MME UE_S1AP_ID
* not containing an eNB_UE_S1AP_ID
* containing a UE_Aggregate_Maximum_Bit_Rate
* containing an E-RAB_to_be_Setup_List
* containing an E-RAB_to_be_Setup Item 1
* containing an E-RAB_ID
* containing an E-RAB_Level_QoS_Parameters
* containing QCI
* indicating value 5
* containing a Transport_Layer_Address
* containing a GTP-TEID
* containing a NAS-PDU
* sends an ERROR_INDICATION
* containing a Criticality_Diagnostics
* containing a Procedure_Code
* containing a Triggering_Message
* containing a Procedure_Criticality
* containing an Information Element Criticality_Diagnostics
* containing an IE_Criticality
* containing an IE_ID
* containing an IE_Type_of_Error.
* </pre>
*
* @see ETSI TS 103 497-2 TP_S1AP_ENB_ERR_05
* @reference ETSI TS 136 413 V13.4.0 Clause 10.3.5¶4(2nd dashed line) and 14
*/
testcase TC_S1AP_ENB_ERR_05() runs on S1AP system TestAdapter {
// Local variables
var S1AP v_s1ap_enb;
// Test control
if (not (PICS_S1AP_eNB_IUT and PICS_S1AP_eNB_INITIATION_ERROR_IND_ABSTRACT_SYNTAX_PROCEDURE)) {
log("*** " & __SCOPE__ & ": ERROR: 'PICS_S1AP_eNB_IUT and PICS_S1AP_eNB_INITIATION_ERROR_IND_ABSTRACT_SYNTAX_PROCEDURE' shall be set to true for executing the TC. ***");
stop;
}
// Test component configuration
f_cf_S1AP_eNB_Up(v_s1ap_enb);
// Start
v_s1ap_enb.start(f_TC_S1AP_ENB_ERR_05());
// synchronize PTC on 1 sychronization points
f_serverSyncNClientsAndStop(1, {c_prDone, c_tbDone, c_poDone});
f_cf_Down();
} // End of testcase TC_S1AP_ENB_ERR_05
/**
* @desc Verify that the IUT rejects the procedure if message contains too many occurrances of the same IEs/IE groups with
* response message for this procedure and report the cause value ‘Abstract Syntax Error(Falsely Constructed Message)’.
* <pre>
2232
2233
2234
2235
2236
2237
2238
2239
2240
2241
2242
2243
2244
2245
2246
2247
2248
2249
2250
2251
2252
2253
2254
2255
2256
2257
2258
2259
2260
2261
2262
2263
2264
2265
2266
2267
2268
2269
2270
2271
2272
2273
2274
2275
2276
2277
2278
2279
2280
2281
2282
2283
2284
2285
2286
2287
2288
2289
2290
2291
2292
* Configuration: CF_S1-MME
* Ensure that the IUT
* on receipt of an INITIAL_CONTEXT_SETUP_REQUEST,
* containing an MME UE_S1AP_ID
* containing an eNB_UE_S1AP_ID
* containing an eNB_UE_S1AP_ID(same IE as already present)
* containing a UE_Aggregate_Maximum_Bit_Rate
* containing an E-RAB_to_be_Setup_List
* containing an E-RAB_to_be_Setup Item 1
* containing an E-RAB_ID
* containing an E-RAB_Level_QoS_Parameters
* containing a Transport_Layer_Address
* containing a GTP-TEID
* containing a NAS-PDU
* containing a UE_Security_Capabilities
* containing an Encription_Algorithms
* indicating not supported algoithm
* containing an Integrity_Protection_Algorithms
* containing a Security_Key
* sends an ERROR_INDICATION
* containing a Criticality_Diagnostics
* containing a Procedure_Code
* containing a Triggering_Message
* containing a Procedure_Criticality
* containing an Information Element Criticality_Diagnostics
* containing an IE_Criticality
* containing an IE_ID
* containing an IE_Type_of_Error.
* </pre>
*
* @see ETSI TS 103 497-2 TP_S1AP_ENB_ERR_06
* @reference ETSI TS 136 413 V13.4.0 Clause 10.3.6¶2(1st dashed line)
*/
testcase TC_S1AP_ENB_ERR_06() runs on S1AP system TestAdapter {
// Local variables
var S1AP v_s1ap_enb;
// Test control
if (not (PICS_S1AP_eNB_IUT and PICS_S1AP_eNB_INITIATION_ERROR_IND_ABSTRACT_SYNTAX_PROCEDURE)) {
log("*** " & __SCOPE__ & ": ERROR: 'PICS_S1AP_eNB_IUT and PICS_S1AP_eNB_INITIATION_ERROR_IND_ABSTRACT_SYNTAX_PROCEDURE' shall be set to true for executing the TC. ***");
stop;
}
// Test component configuration
f_cf_S1AP_eNB_Up(v_s1ap_enb);
// Start
v_s1ap_enb.start(f_TC_S1AP_ENB_ERR_06());
// synchronize PTC on 1 sychronization points
f_serverSyncNClientsAndStop(1, {c_prDone, c_tbDone, c_poDone});
f_cf_Down();
} // End of testcase TC_S1AP_ENB_ERR_06
/**
* @desc Verify that the IUT terminate the procedure that does not have message to report unsuccessful outcome and message contains
* too many occurrances of the same IEs/IE groups and initiate Error Indication Procedure with cause value
* ‘Abstract Syntax Error(Falsely Constructed Message)’.
* <pre>
2294
2295
2296
2297
2298
2299
2300
2301
2302
2303
2304
2305
2306
2307
2308
2309
2310
2311
2312
2313
2314
2315
2316
2317
2318
2319
2320
2321
2322
2323
2324
2325
2326
2327
2328
2329
2330
2331
2332
2333
2334
2335
2336
2337
2338
2339
2340
2341
2342
2343
2344
2345
* Configuration: CF_S1-MME
* Ensure that the IUT
* on receipt of an E-RAB_SETUP_REQUEST,
* containing an MME UE_S1AP_ID
* containing an eNB_UE_S1AP_ID
* containing an eNB_UE_S1AP_ID(same IE as already present)
* containing a UE_Aggregate_Maximum_Bit_Rate
* containing an E-RAB_to_be_Setup_List
* containing an E-RAB_to_be_Setup Item 1
* containing an E-RAB_ID
* containing an E-RAB_Level_QoS_Parameters
* containing QCI
* indicating value 5
* containing a Transport_Layer_Address
* containing a GTP-TEID
* containing a NAS-PDU
* sends an ERROR_INDICATION
* containing a Cause
* indicating ‘Abstract Syntax Error(Falsely Constructed Message)’.
* </pre>
*
* @see ETSI TS 103 497-2 TP_S1AP_ENB_ERR_07
* @reference ETSI TS 136 413 V13.4.0 Clause 10.3.5¶3(2nd dashed line)
*/
testcase TC_S1AP_ENB_ERR_07() runs on S1AP system TestAdapter {
// Local variables
var S1AP v_s1ap_enb;
// Test control
if (not (PICS_S1AP_eNB_IUT and PICS_S1AP_eNB_INITIATION_ERROR_IND_ABSTRACT_SYNTAX_PROCEDURE)) {
log("*** " & __SCOPE__ & ": ERROR: 'PICS_S1AP_eNB_IUT and PICS_S1AP_eNB_INITIATION_ERROR_IND_ABSTRACT_SYNTAX_PROCEDURE' shall be set to true for executing the TC. ***");
stop;
}
// Test component configuration
f_cf_S1AP_eNB_Up(v_s1ap_enb);
// Start
v_s1ap_enb.start(f_TC_S1AP_ENB_ERR_07());
// synchronize PTC on 1 sychronization points
f_serverSyncNClientsAndStop(1, {c_prDone, c_tbDone, c_poDone});
f_cf_Down();
} // End of testcase TC_S1AP_ENB_ERR_07
/**
* @desc Verify that the IUT initiate an Error Indication procedure with inclusion of only the previousy received AP ID from the peer node
* and appropriate cause value in case if AP ID has been stored previously for another UE-associated logical connection for same
* peer node.
* <pre>
2347
2348
2349
2350
2351
2352
2353
2354
2355
2356
2357
2358
2359
2360
2361
2362
2363
2364
2365
2366
2367
2368
2369
2370
2371
2372
2373
2374
2375
2376
2377
2378
2379
2380
2381
2382
2383
2384
2385
2386
2387
2388
2389
2390
2391
2392
2393
2394
2395
* Configuration: CF_S1-MME
* Ensure that the IUT
* on receipt of an E-RAB_SETUP_REQUEST,
* containing an MME UE_S1AP_ID
* indicating already used AP ID
* containing an eNB_UE_S1AP_ID
* indicating already used AP ID
* containing a UE_Aggregate_Maximum_Bit_Rate
* containing an E-RAB_to_be_Setup_List
* containing an E-RAB_to_be_Setup Item 1
* containing an E-RAB_ID
* containing an E-RAB_Level_QoS_Parameters
* containing QCI
* indicating value 5
* containing a Transport_Layer_Address
* containing a GTP-TEID
* containing a NAS-PDU
* sends an ERROR_INDICATION
* containing an eNB_UE_S1AP_ID
* containing a Cause
* indicating ‘Unknown or already allocated eNB UE S1AP ID’.
* </pre>
*
* @see ETSI TS 103 497-2 TP_S1AP_ENB_ERR_08
* @reference ETSI TS 136 413 V13.4.0 Clause 10.3.5¶3(2nd dashed line)
*/
testcase TC_S1AP_ENB_ERR_08() runs on S1AP system TestAdapter {
// Local variables
var S1AP v_s1ap_enb;
// Test control
if (not (PICS_S1AP_eNB_IUT and PICS_S1AP_eNB_INITIATION_ERROR_IND_ABSTRACT_SYNTAX_PROCEDURE)) {
log("*** " & __SCOPE__ & ": ERROR: 'PICS_S1AP_eNB_IUT and PICS_S1AP_eNB_INITIATION_ERROR_IND_ABSTRACT_SYNTAX_PROCEDURE' shall be set to true for executing the TC. ***");
stop;
}
// Test component configuration
f_cf_S1AP_eNB_Up(v_s1ap_enb);
// Start
v_s1ap_enb.start(f_TC_S1AP_ENB_ERR_08());
// synchronize PTC on 1 sychronization points
f_serverSyncNClientsAndStop(1, {c_prDone, c_tbDone, c_poDone});
f_cf_Down();
} // End of testcase TC_S1AP_ENB_ERR_08
} // End of group Unknown_unforseen_errorneous_group
/**
* @desc E-RAB management group
* @see ETSI TS 103 497-2 Clause 5.2.2.2.2 E-RAB management group
*/
/**
* @desc Verify that the IUT can send an E-RAB_SETUP_REQUEST with at least one E-RAB IE to indicate an E-RAB Setup procedure.
* <pre>
* Configuration: CF_S1-MME
* Ensure that the IUT
* to indicate an E-RAB Setup procedure,
* sends an E-RAB_SETUP_REQUEST
* containing an MME_UE_S1AP_ID
* containing an eNB_UE_S1AP_ID
* containing an E-RAB_to_be_Setup_List
* containing an E-RAB_to_be_Setup Item 1
* containing an E-RAB_ID
* containing an E-RAB_Level_QoS_Parameters
* containing a Transport_Layer_Address
* containing a GTP-TEID
* containing a NAS-PDU.
* </pre>
*
* @see ETSI TS 103 497-2 TP_S1AP_eNB_RAB_01
* @reference ETSI TS 136 413 V13.4.0 Clause 8.2.1.2 and 9.1.3.1
*/
testcase TC_S1AP_MME_RAB_01() runs on S1AP system TestAdapter {
// Test control
if (not PICS_S1AP_MME_IUT) {
log("*** " & __SCOPE__ & ": ERROR: 'PICS_S1AP_MME_IUT' shall be set to true for executing the TC. ***");
stop;
}
v_s1ap_mme.start(f_TC_S1AP_MME_RAB_01());
// synchronize PTC on 1 sychronization points
f_serverSyncNClientsAndStop(1, {c_prDone, c_tbDone, c_poDone});
} // End of testcase TC_S1AP_MME_RAB_01
} // End of group ERAB_management_group
group Context_Management_group {
2457
2458
2459
2460
2461
2462
2463
2464
2465
2466
2467
2468
2469
2470
2471
2472
2473
2474
2475
2476
2477
2478
2479
2480
2481
2482
2483
2484
2485
2486
2487
2488
2489
2490
2491
2492
2493
2494
2495
2496
2497
2498
2499
2500
2501
testcase TC_S1AP_MME_CMP_01() runs on S1AP system TestAdapter {
// Local variables
var S1AP v_s1ap_mme;
// Test control
if (not PICS_S1AP_MME_IUT) {
log("*** " & __SCOPE__ & ": ERROR: 'PICS_S1AP_MME_IUT' shall be set to true for executing the TC. ***");
stop;
}
// Test component configuration
f_cf_S1AP_MME_Up(v_s1ap_mme);
// Start
v_s1ap_mme.start(f_TC_S1AP_mME_CMP_01());
// synchronize PTC on 1 sychronization points
f_serverSyncNClientsAndStop(1, {c_prDone, c_tbDone, c_poDone});
f_cf_Down();
} // End of testcase TC_S1AP_MME_CMP_01
testcase TC_S1AP_MME_CMP_02() runs on S1AP system TestAdapter {
// Local variables
var S1AP v_s1ap_mme;
// Test control
if (not PICS_S1AP_MME_IUT) {
log("*** " & __SCOPE__ & ": ERROR: 'PICS_S1AP_MME_IUT' shall be set to true for executing the TC. ***");
stop;
}
// Test component configuration
f_cf_S1AP_MME_Up(v_s1ap_mme);
// Start
v_s1ap_mme.start(f_TC_S1AP_mME_CMP_02());
// synchronize PTC on 1 sychronization points
f_serverSyncNClientsAndStop(1, {c_prDone, c_tbDone, c_poDone});
f_cf_Down();
} // End of testcase TC_S1AP_MME_CMP_02
2503
2504
2505
2506
2507
2508
2509
2510
2511
2512
2513
2514
2515
2516
2517
2518
2519
2520
2521
2522
2523
2524
2525
2526
2527
2528
2529
2530
2531
2532
2533
2534
2535
2536
2537
2538
2539
2540
2541
2542
2543
2544
2545
2546
2547
2548
2549
2550
2551
2552
2553
2554
2555
2556
2557
2558
2559
2560
2561
2562
2563
2564
2565
2566
2567
2568
2569
2570
2571
2572
2573
2574
2575
2576
2577
2578
2579
2580
2581
2582
2583
2584
2585
2586
2587
2588
2589
2590
2591
2592
2593
2594
2595
2596
2597
2598
2599
2600
2601
2602
2603
2604
2605
2606
2607
2608
2609
2610
2611
2612
2613
2614
2615
2616
2617
2618
2619
2620
2621
2622
2623
2624
2625
2626
2627
2628
2629
2630
2631
2632
2633
2634
2635
2636
2637
2638
2639
2640
2641
2642
2643
2644
2645
2646
2647
2648
2649
2650
2651
2652
2653
2654
2655
2656
2657
2658
2659
2660
2661
2662
2663
2664
2665
2666
2667
2668
2669
2670
2671
2672
2673
2674
2675
2676
2677
2678
2679
2680
2681
2682
2683
2684
2685
2686
2687
2688
2689
2690
2691
2692
2693
2694
2695
2696
2697
2698
2699
2700
2701
2702
2703
2704
2705
2706
2707
2708
2709
testcase TC_S1AP_MME_CMP_03() runs on S1AP system TestAdapter {
// Local variables
var S1AP v_s1ap_mme;
// Test control
if (not PICS_S1AP_MME_IUT) {
log("*** " & __SCOPE__ & ": ERROR: 'PICS_S1AP_MME_IUT' shall be set to true for executing the TC. ***");
stop;
}
// Test component configuration
f_cf_S1AP_MME_Up(v_s1ap_mme);
// Start
v_s1ap_mme.start(f_TC_S1AP_mME_CMP_03());
// synchronize PTC on 1 sychronization points
f_serverSyncNClientsAndStop(1, {c_prDone, c_tbDone, c_poDone});
f_cf_Down();
} // End of testcase TC_S1AP_MME_CMP_03
testcase TC_S1AP_MME_CMP_04() runs on S1AP system TestAdapter {
// Local variables
var S1AP v_s1ap_mme;
// Test control
if (not PICS_S1AP_MME_IUT) {
log("*** " & __SCOPE__ & ": ERROR: 'PICS_S1AP_MME_IUT' shall be set to true for executing the TC. ***");
stop;
}
// Test component configuration
f_cf_S1AP_MME_Up(v_s1ap_mme);
// Start
v_s1ap_mme.start(f_TC_S1AP_mME_CMP_04());
// synchronize PTC on 1 sychronization points
f_serverSyncNClientsAndStop(1, {c_prDone, c_tbDone, c_poDone});
f_cf_Down();
} // End of testcase TC_S1AP_MME_CMP_04
testcase TC_S1AP_MME_CMP_05() runs on S1AP system TestAdapter {
// Local variables
var S1AP v_s1ap_mme;
// Test control
if (not PICS_S1AP_MME_IUT) {
log("*** " & __SCOPE__ & ": ERROR: 'PICS_S1AP_MME_IUT' shall be set to true for executing the TC. ***");
stop;
}
// Test component configuration
f_cf_S1AP_MME_Up(v_s1ap_mme);
// Start
v_s1ap_mme.start(f_TC_S1AP_mME_CMP_05());
// synchronize PTC on 1 sychronization points
f_serverSyncNClientsAndStop(1, {c_prDone, c_tbDone, c_poDone});
f_cf_Down();
} // End of testcase TC_S1AP_MME_CMP_05
testcase TC_S1AP_MME_CMP_06() runs on S1AP system TestAdapter {
// Local variables
var S1AP v_s1ap_mme;
// Test control
if (not PICS_S1AP_MME_IUT) {
log("*** " & __SCOPE__ & ": ERROR: 'PICS_S1AP_MME_IUT' shall be set to true for executing the TC. ***");
stop;
}
// Test component configuration
f_cf_S1AP_MME_Up(v_s1ap_mme);
// Start
v_s1ap_mme.start(f_TC_S1AP_mME_CMP_06());
// synchronize PTC on 1 sychronization points
f_serverSyncNClientsAndStop(1, {c_prDone, c_tbDone, c_poDone});
f_cf_Down();
} // End of testcase TC_S1AP_MME_CMP_06
testcase TC_S1AP_MME_CMP_07() runs on S1AP system TestAdapter {
// Local variables
var S1AP v_s1ap_mme;
// Test control
if (not PICS_S1AP_MME_IUT) {
log("*** " & __SCOPE__ & ": ERROR: 'PICS_S1AP_MME_IUT' shall be set to true for executing the TC. ***");
stop;
}
// Test component configuration
f_cf_S1AP_MME_Up(v_s1ap_mme);
// Start
v_s1ap_mme.start(f_TC_S1AP_mME_CMP_07());
// synchronize PTC on 1 sychronization points
f_serverSyncNClientsAndStop(1, {c_prDone, c_tbDone, c_poDone});
f_cf_Down();
} // End of testcase TC_S1AP_MME_CMP_07
testcase TC_S1AP_MME_CMP_08() runs on S1AP system TestAdapter {
// Local variables
var S1AP v_s1ap_mme;
// Test control
if (not PICS_S1AP_MME_IUT) {
log("*** " & __SCOPE__ & ": ERROR: 'PICS_S1AP_MME_IUT' shall be set to true for executing the TC. ***");
stop;
}
// Test component configuration
f_cf_S1AP_MME_Up(v_s1ap_mme);
// Start
v_s1ap_mme.start(f_TC_S1AP_mME_CMP_08());
// synchronize PTC on 1 sychronization points
f_serverSyncNClientsAndStop(1, {c_prDone, c_tbDone, c_poDone});
f_cf_Down();
} // End of testcase TC_S1AP_MME_CMP_08
testcase TC_S1AP_MME_CMP_09() runs on S1AP system TestAdapter {
// Local variables
var S1AP v_s1ap_mme;
// Test control
if (not PICS_S1AP_MME_IUT) {
log("*** " & __SCOPE__ & ": ERROR: 'PICS_S1AP_MME_IUT' shall be set to true for executing the TC. ***");
stop;
}
// Test component configuration
f_cf_S1AP_MME_Up(v_s1ap_mme);
// Start
v_s1ap_mme.start(f_TC_S1AP_mME_CMP_09());
// synchronize PTC on 1 sychronization points
f_serverSyncNClientsAndStop(1, {c_prDone, c_tbDone, c_poDone});
f_cf_Down();
} // End of testcase TC_S1AP_MME_CMP_09
testcase TC_S1AP_MME_CMP_10() runs on S1AP system TestAdapter {
// Local variables
var S1AP v_s1ap_mme;
// Test control
if (not PICS_S1AP_MME_IUT) {
log("*** " & __SCOPE__ & ": ERROR: 'PICS_S1AP_MME_IUT' shall be set to true for executing the TC. ***");
stop;
}
// Test component configuration
f_cf_S1AP_MME_Up(v_s1ap_mme);
// Start
v_s1ap_mme.start(f_TC_S1AP_mME_CMP_10());
// synchronize PTC on 1 sychronization points
f_serverSyncNClientsAndStop(1, {c_prDone, c_tbDone, c_poDone});
f_cf_Down();
} // End of testcase TC_S1AP_MME_CMP_10
testcase TC_S1AP_MME_CMP_11() runs on S1AP system TestAdapter {
// Local variables
var S1AP v_s1ap_mme;
// Test control
if (not PICS_S1AP_MME_IUT) {
log("*** " & __SCOPE__ & ": ERROR: 'PICS_S1AP_MME_IUT' shall be set to true for executing the TC. ***");
stop;
}
// Test component configuration
f_cf_S1AP_MME_Up(v_s1ap_mme);
// Start
v_s1ap_mme.start(f_TC_S1AP_mME_CMP_11());
// synchronize PTC on 1 sychronization points
f_serverSyncNClientsAndStop(1, {c_prDone, c_tbDone, c_poDone});
f_cf_Down();
} // End of testcase TC_S1AP_MME_CMP_11
} // End of group Context_Management_group
2713
2714
2715
2716
2717
2718
2719
2720
2721
2722
2723
2724
2725
2726
2727
2728
2729
2730
2731
2732
2733
2734
2735
2736
2737
2738
2739
2740
2741
2742
2743
2744
2745
2746
2747
2748
2749
2750
2751
2752
2753
2754
2755
2756
2757
2758
* @desc Paging group
* @see ETSI TS 103 497-2 Clause 5.2.2.2.5 Paging group
*/
group Pagin_group {
/**
* @desc Verify that the IUT can send a PAGING to indicate a Paging procedure.
* <pre>
* Pics Selection: A.4/4.4
* Configuration: CF_S1-MME
* Ensure that the IUT
* to indicate a Paging procedure
* sends a PAGING
* containing a UE_Identity_Index_value
* containing a UE_Paging_Identity
* containing a S-TMSI
* containing an IMSI
* containing a CN_Domain.
* </pre>
*
* @see ETSI TS 103 497-2 TP_S1AP_MME_PAG_01
* @reference ETSI TS 136 413 V13.4.0 Clause 8.5.2¶1 and 9.1.6
*/
testcase TC_S1AP_MME_PAG_01() runs on S1AP system TestAdapter {
// Local variables
var S1AP v_s1ap_mme;
// Test control
if (not PICS_S1AP_MME_IUT) {
log("*** " & __SCOPE__ & ": ERROR: 'PICS_S1AP_MME_IUT' shall be set to true for executing the TC. ***");
stop;
}
// Test component direct information
f_cf_S1AP_MME_Up(v_s1ap_mme);
// Start
v_s1ap_mme.start(f_TC_S1AP_MME_PAG_01());
// synchronize PTC on 1 sychronization points
f_serverSyncNClientsAndStop(1, {c_prDone, c_tbDone, c_poDone});
f_cf_Down();
} // End of testcase TC_S1AP_MME_PAG_01
* @see ETSI TS 103 497-2 Clause 5.2.2.1.6 NAS transport group
*/
group NAS_transport_group {
/**
* @desc Verify that the IUT can send a DOWNLINK_NAS_TRANSPORT to indicate an ongoing NAS Transport procedure.
* <pre>
* Pics Selection: A.4/5.2
* Configuration: CF_S1-MME
* Ensure that the IUT
* to indicate an ongoing NAS Transport procedure
* sends a DOWNLINK_NAS_TRANSPORT
* containing an MME UE S1AP ID
* containing an eNB_UE_S1AP_ID
* containing a NAS-PDU.
* </pre>
*
* @see ETSI TS 103 497-2 TP_S1AP_MME_NAS_01
2781
2782
2783
2784
2785
2786
2787
2788
2789
2790
2791
2792
2793
2794
2795
2796
2797
2798
2799
2800
2801
2802
2803
2804
2805
2806
2807
2808
2809
2810
2811
2812
2813
2814
2815
2816
2817
2818
* @reference ETSI TS 136 413 V13.4.0 Clause 8.6.2.2¶1 and 9.1.7.2
*/
testcase TC_S1AP_MME_NAS_01() runs on S1AP system TestAdapter {
// Local variables
var S1AP v_s1ap_mme;
// Test control
if (not PICS_S1AP_MME_IUT) {
log("*** " & __SCOPE__ & ": ERROR: 'PICS_S1AP_MME_IUT' shall be set to true for executing the TC. ***");
stop;
}
// Test component direct information
f_cf_S1AP_MME_Up(v_s1ap_mme);
// Start
v_s1ap_mme.start(f_TC_S1AP_MME_NAS_01());
// synchronize PTC on 1 sychronization points
f_serverSyncNClientsAndStop(1, {c_prDone, c_tbDone, c_poDone});
f_cf_Down();
} // End of testcase TC_S1AP_MME_NAS_01
/**
* @desc Verify that the IUT can send a REROUTE_NAS_REQUEST to indicate a Reroute NAS Request procedure.
* <pre>
* Pics Selection: A.4/5.5
* Configuration: CF_S1-MME
* Ensure that the IUT
* to indicate a Reroute NAS Request procedure
* sends a REROUTE_NAS_REQUEST
* containing an MME UE S1AP ID
* containing a S1_Message
* containing an MME_Group_ID.
* </pre>
*
* @see ETSI TS 103 497-2 TP_S1AP_MME_NAS_02
2820
2821
2822
2823
2824
2825
2826
2827
2828
2829
2830
2831
2832
2833
2834
2835
2836
2837
2838
2839
2840
2841
2842
2843
2844
2845
2846
* @reference ETSI TS 136 413 V13.4.0 Clause 8.6.2.2¶1 and 9.1.7.2
*/
testcase TC_S1AP_MME_NAS_02() runs on S1AP system TestAdapter {
// Local variables
var S1AP v_s1ap_mme;
// Test control
if (not PICS_S1AP_MME_IUT) {
log("*** " & __SCOPE__ & ": ERROR: 'PICS_S1AP_MME_IUT' shall be set to true for executing the TC. ***");
stop;
}
// Test component direct information
f_cf_S1AP_MME_Up(v_s1ap_mme);
// Start
v_s1ap_mme.start(f_TC_S1AP_MME_NAS_02());
// synchronize PTC on 1 sychronization points
f_serverSyncNClientsAndStop(1, {c_prDone, c_tbDone, c_poDone});
f_cf_Down();
} // End of testcase TC_S1AP_MME_NAS_02
} // End of group NAS_transport_group
/**
* @desc Management group
* @see ETSI TS 103 497-2 Clause 5.2.2.2.7 Management group
*/
group Management_group {
/**
* @desc Verify that the IUT can send a RESET to indicate a Reset procedure initiated from the MME.
* <pre>
* Pics Selection: A.4/6.1.2
* Ensure that the IUT
* to indicate a Reset procedure initiated from the MME
* sends a RESET
* containing a Cause
* indicating an appropriate cause value
* containing a Reset_Type
* containing a S1_Interface
* indicating a value ‘Reset_all’.
* </pre>
*
* @see ETSI TS 103 497-2 TP_S1AP_MME_MNP_01
2869
2870
2871
2872
2873
2874
2875
2876
2877
2878
2879
2880
2881
2882
2883
2884
2885
2886
2887
2888
2889
2890
2891
2892
2893
2894
* @reference ETSI TS 136 413 V13.4.0 Clause 8.7.1.2.1¶2 and 9.1.8.1 and 9.1.8.2
*/
testcase TC_S1AP_MME_MNP_01() runs on S1AP system TestAdapter {
// Local variables
var S1AP v_s1ap_mme;
// Test control
if (not PICS_S1AP_MME_IUT) {
log("*** " & __SCOPE__ & ": ERROR: 'PICS_S1AP_MME_IUT' shall be set to true for executing the TC. ***");
stop;
}
// Test component direct information
f_cf_S1AP_MME_Up(v_s1ap_mme);
// Start
v_s1ap_mme.start(f_TC_S1AP_MME_MNP_01());
// synchronize PTC on 1 sychronization points
f_serverSyncNClientsAndStop(1, {c_prDone, c_tbDone, c_poDone});
f_cf_Down();
} // End of testcase TC_S1AP_MME_MNP_01
/**
* @desc Verify that the IUT can send process successfully all mandatory IEs in a RESET and sends a RESET_ACKNOWLEDGE
* <pre>
* Pics Selection: A.4/6.1.1
* Ensure that the IUT
* on receipt of a RESET
* containing a Cause
* indicating an appropriate cause value
* containing a Reset_Type
* containing an S1_Interface
* indicating value ‘Reset_all’
* sends a RESET_ACKNOWLEDGE
* containing a UE-associated_logical_S1-connection_list.
* </pre>
*
* @see ETSI TS 103 497-2 TP_S1AP_MME_MNP_02
* @reference ETSI TS 136 413 V13.4.0 Clause 8.7.1.2.1¶2 and 9.1.8.1 and 9.1.8.2
2913
2914
2915
2916
2917
2918
2919
2920
2921
2922
2923
2924
2925
2926
2927
2928
2929
2930
2931
2932
2933
2934
2935
2936
*/
testcase TC_S1AP_MME_MNP_02() runs on S1AP system TestAdapter {
// Local variables
var S1AP v_s1ap_mme;
// Test control
if (not PICS_S1AP_MME_IUT) {
log("*** " & __SCOPE__ & ": ERROR: 'PICS_S1AP_MME_IUT' shall be set to true for executing the TC. ***");
stop;
}
// Test component direct information
f_cf_S1AP_MME_Up(v_s1ap_mme);
// Start
v_s1ap_mme.start(f_TC_S1AP_MME_MNP_02());
// synchronize PTC on 1 sychronization points
f_serverSyncNClientsAndStop(1, {c_prDone, c_tbDone, c_poDone});
f_cf_Down();
} // End of testcase TC_S1AP_MME_MNP_02
* @desc Verify that the IUT can successfully all mandatory IEs in a RESET and sends a RESET_ACKNOWLEDGE
* due to a Reset procedure in case of Abnormal Condition at the EPC.
* <pre>
* Pics Selection: A.4/6.1.1
* Configuration: CF_S1-MME
* Ensure that the IUT
* on receipt of a RESET
* containing a Cause
* indicating an appropriate cause value
* containing a Reset_Type
* containing a Part_of_S1_interface
* indicating an empty ‘UE-associated_logical_S1-connection’
* sends a RESET_ACKNOWLEDGE
* containing a UE-associated_logical_S1-connection_list
* indicating an empty ‘UE-associated_logical_S1-connection’.
* </pre>
*
* @see ETSI TS 103 497-2 TP_S1AP_MME_MNP_03
2956
2957
2958
2959
2960
2961
2962
2963
2964
2965
2966
2967
2968
2969
2970
2971
2972
2973
2974
2975
2976
2977
2978
2979
2980
2981
2982
2983
2984
2985
2986
2987
2988
2989
2990
2991
2992
* @reference ETSI TS 136 413 V13.4.0 Clause 8.7.1.3.2¶1 and 9.1.8.1 and 9.1.8.2
*/
testcase TC_S1AP_MME_MNP_03() runs on S1AP system TestAdapter {
// Local variables
var S1AP v_s1ap_mme;
// Test control
if (not PICS_S1AP_MME_IUT) {
log("*** " & __SCOPE__ & ": ERROR: 'PICS_S1AP_MME_IUT' shall be set to true for executing the TC. ***");
stop;
}
// Test component direct information
f_cf_S1AP_MME_Up(v_s1ap_mme);
// Start
v_s1ap_mme.start(f_TC_S1AP_MME_MNP_03());
// synchronize PTC on 1 sychronization points
f_serverSyncNClientsAndStop(1, {c_prDone, c_tbDone, c_poDone});
f_cf_Down();
} // End of testcase TC_S1AP_MME_MNP_03
/**
* @desc Verify that the IUT can send a RESET to indicate a Reset procedure initiated from the eNB.
* <pre>
* Pics Selection: A.4/6.2.2
* Configuration: CF_S1-MME
* Ensure that the IUT
* to indicate an Error Indication procedure
* sends an ERROR_INDICATION
* (containing a Cause
* or containing a Criticality_Diagnostics).
* </pre>
*
* @see ETSI TS 103 497-2 TP_S1AP_MME_MNP_04
2994
2995
2996
2997
2998
2999
3000
3001
3002
3003
3004
3005
3006
3007
3008
3009
3010
3011
3012
3013
3014
3015
3016
3017
3018
3019
* @reference ETSI TS 136 413 V13.4.0 Clause 8.7.1.2.1¶2 and 9.1.8.1 and 9.1.8.2
*/
testcase TC_S1AP_MME_MNP_04() runs on S1AP system TestAdapter {
// Local variables
var S1AP v_s1ap_mme;
// Test control
if (not PICS_S1AP_MME_IUT) {
log("*** " & __SCOPE__ & ": ERROR: 'PICS_S1AP_MME_IUT' shall be set to true for executing the TC. ***");
stop;
}
// Test component direct information
f_cf_S1AP_MME_Up(v_s1ap_mme);
// Start
v_s1ap_mme.start(f_TC_S1AP_MME_MNP_04());
// synchronize PTC on 1 sychronization points
f_serverSyncNClientsAndStop(1, {c_prDone, c_tbDone, c_poDone});
f_cf_Down();
} // End of testcase TC_S1AP_MME_MNP_04
/**
* @desc Verify that the IUT can process all mandatory IEs in a S1_SETUP_REQUEST and
* sends a S1_SETUP_RESPONSE to indicate a S1 Setup procedure.
* <pre>
* Pics Selection: A.4/6.3
* Configuration: CF_S1-MME
* Ensure that the IUT
* on receipt of a S1_SETUP_REQUEST
* containing a Global_eNB_ID
* containing a Supported_TAs
* containing a TAC
* containing a Default_Paging_DRX
* sends a S1_SETUP_RESPONSE.
* </pre>
*
* @see ETSI TS 103 497-2 TP_S1AP_MME_MNP_05
3035
3036
3037
3038
3039
3040
3041
3042
3043
3044
3045
3046
3047
3048
3049
3050
3051
3052
3053
3054
3055
3056
3057
3058
3059
* @reference ETSI TS 136 413 V13.4.0 Clause 8.7.3.2¶1 and 9.1.8.4 and 9.1.8.5
*/
testcase TC_S1AP_MME_MNP_05() runs on S1AP system TestAdapter {
// Local variables
var S1AP v_s1ap_mme;
// Test control
if (not PICS_S1AP_MME_IUT) {
log("*** " & __SCOPE__ & ": ERROR: 'PICS_S1AP_MME_IUT' shall be set to true for executing the TC. ***");
stop;
}
// Test component direct information
f_cf_S1AP_MME_Up(v_s1ap_mme);
// Start
v_s1ap_mme.start(f_TC_S1AP_MME_MNP_05());
// synchronize PTC on 1 sychronization points
f_serverSyncNClientsAndStop(1, {c_prDone, c_tbDone, c_poDone});
f_cf_Down();
} // End of testcase TC_S1AP_MME_MNP_05
/**
* @desc Verify that the IUT can process all mandatory IEs in a S1_SETUP_REQUEST and
* sends a S1_SETUP_FAILURE to indicate an invalid S1 Setup procedure due to an unknown PLMN identities.
* <pre>
* Pics Selection: A.4/6.3
* Configuration: CF_S1-MME
* Ensure that the IUT
* on receipt of a S1_SETUP_REQUEST
* containing a Global_eNB_ID
* containing a Supported_TAs
* containing a TAC
* containing a Broadcast_PLMNs
* indicating at least one unknown PLMN identity
* sends a S1_SETUP_FAILURE
* containing a Cause
* indicating the cause value 'Unknown PLMN'.
* </pre>
*
* @see ETSI TS 103 497-2 TP_S1AP_MME_MNP_06
3079
3080
3081
3082
3083
3084
3085
3086
3087
3088
3089
3090
3091
3092
3093
3094
3095
3096
3097
3098
3099
3100
3101
3102
3103
3104
3105
3106
3107
3108
3109
3110
3111
3112
3113
3114
3115
3116
3117
* @reference ETSI TS 136 413 V13.4.0 Clause 8.7.3.2¶1 and 9.1.8.4 and 9.1.8.6
*/
testcase TC_S1AP_MME_MNP_06() runs on S1AP system TestAdapter {
// Local variables
var S1AP v_s1ap_mme;
// Test control
if (not PICS_S1AP_MME_IUT) {
log("*** " & __SCOPE__ & ": ERROR: 'PICS_S1AP_MME_IUT' shall be set to true for executing the TC. ***");
stop;
}
// Test component direct information
f_cf_S1AP_MME_Up(v_s1ap_mme);
// Start
v_s1ap_mme.start(f_TC_S1AP_MME_MNP_06());
// synchronize PTC on 1 sychronization points
f_serverSyncNClientsAndStop(1, {c_prDone, c_tbDone, c_poDone});
f_cf_Down();
} // End of testcase TC_S1AP_MME_MNP_06
/**
* @desc Verify that the IUT can process all mandatory IEs in an ENB_CONFIGURATION_UPDATE and
* sends an ENB_CONFIGURATION_UPDATE_ACKNOWLEDGE to indicate an eNB Configuration Update procedure.
* <pre>
* Pics Selection: A.4/6.4
* Configuration: CF_S1-MME
* Ensure that the IUT
* on receipt of an ENB_CONFIGURATION_UPDATE
* containing a Global_eNB_ID
* containing a Supported_TAs
* containing a TAC
* sends an MME_CONFIGURATION_UPDATE_ACKNOWLEDGE.
* </pre>
*
* @see ETSI TS 103 497-2 TP_S1AP_MME_MNP_07
3119
3120
3121
3122
3123
3124
3125
3126
3127
3128
3129
3130
3131
3132
3133
3134
3135
3136
3137
3138
3139
3140
3141
3142
3143
3144
3145
3146
3147
3148
3149
3150
3151
3152
3153
3154
3155
3156
3157
3158
* @reference ETSI TS 136 413 V13.4.0 Clause 8.7.4.2¶1 and 9.1.8.7 and 9.1.8.8
*/
testcase TC_S1AP_MME_MNP_07() runs on S1AP system TestAdapter {
// Local variables
var S1AP v_s1ap_mme;
// Test control
if (not PICS_S1AP_MME_IUT) {
log("*** " & __SCOPE__ & ": ERROR: 'PICS_S1AP_MME_IUT' shall be set to true for executing the TC. ***");
stop;
}
// Test component direct information
f_cf_S1AP_MME_Up(v_s1ap_mme);
// Start
v_s1ap_mme.start(f_TC_S1AP_MME_MNP_07());
// synchronize PTC on 1 sychronization points
f_serverSyncNClientsAndStop(1, {c_prDone, c_tbDone, c_poDone});
f_cf_Down();
} // End of testcase TC_S1AP_MME_MNP_07
/**
* @desc Verify that the IUT can process all mandatory IEs in an ENB_CONFIGURATION_UPDATE and
* sends an ENB_CONFIGURATION_UPDATE_FAILURE to indicate an invalid eNB Configuration Update procedure due to an invalid Global eNB identifier.
* <pre>
* Pics Selection: A.4/6.4
* Configuration: CF_S1-MME
* Ensure that the IUT
* on receipt of an ENB_CONFIGURATION_UPDATE
* containing a Global_eNB_ID
* indicating invalid value
* sends an ENB_CONFIGURATION_UPDATE_FAILURE
* containing a Cause
* indicating an appropriate cause value.
* </pre>
*
* @see ETSI TS 103 497-2 TP_S1AP_MME_MNP_08
3160
3161
3162
3163
3164
3165
3166
3167
3168
3169
3170
3171
3172
3173
3174
3175
3176
3177
3178
3179
3180
3181
3182
3183
3184
3185
3186
3187
3188
3189
3190
3191
3192
3193
3194
3195
3196
3197
* @reference ETSI TS 136 413 V13.4.0 Clause 8.7.3.2¶1 and 9.1.8.7 and 9.1.8.9
*/
testcase TC_S1AP_MME_MNP_08() runs on S1AP system TestAdapter {
// Local variables
var S1AP v_s1ap_mme;
// Test control
if (not PICS_S1AP_MME_IUT) {
log("*** " & __SCOPE__ & ": ERROR: 'PICS_S1AP_MME_IUT' shall be set to true for executing the TC. ***");
stop;
}
// Test component direct information
f_cf_S1AP_MME_Up(v_s1ap_mme);
// Start
v_s1ap_mme.start(f_TC_S1AP_MME_MNP_08());
// synchronize PTC on 1 sychronization points
f_serverSyncNClientsAndStop(1, {c_prDone, c_tbDone, c_poDone});
f_cf_Down();
} // End of testcase TC_S1AP_MME_MNP_08
/**
* @desc Verify that the IUT can send an ENB_CONFIGURATION_UPDATE to indicate an eNB Configuration Update procedure.
* <pre>
* Pics Selection: A.4/6.5
* Configuration: CF_S1-MME
* Ensure that the IUT
* to indicate an eNB Configuration Update procedure
* sends an ENB_CONFIGURATION_UPDATE
* containing a Global_eNB_ID
* containing a Supported_TAs
* containing a TAC.
* </pre>
*
* @see ETSI TS 103 497-2 TP_S1AP_MME_MNP_09
3199
3200
3201
3202
3203
3204
3205
3206
3207
3208
3209
3210
3211
3212
3213
3214
3215
3216
3217
3218
3219
3220
3221
3222
3223
3224
3225
3226
3227
3228
3229
3230
3231
3232
3233
3234
* @reference ETSI TS 136 413 V13.4.0 Clause 8.7.4.2¶1 and 9.1.8.10
*/
testcase TC_S1AP_MME_MNP_09() runs on S1AP system TestAdapter {
// Local variables
var S1AP v_s1ap_mme;
// Test control
if (not PICS_S1AP_MME_IUT) {
log("*** " & __SCOPE__ & ": ERROR: 'PICS_S1AP_MME_IUT' shall be set to true for executing the TC. ***");
stop;
}
// Test component direct information
f_cf_S1AP_MME_Up(v_s1ap_mme);
// Start
v_s1ap_mme.start(f_TC_S1AP_MME_MNP_09());
// synchronize PTC on 1 sychronization points
f_serverSyncNClientsAndStop(1, {c_prDone, c_tbDone, c_poDone});
f_cf_Down();
} // End of testcase TC_S1AP_MME_MNP_09
/**
* @desc Verify that the IUT can send an OVERLOAD_START to indicate an Overload Start procedure.
* <pre>
* Pics Selection: A.4/6.6
* Configuration: CF_S1-MME
* Ensure that the IUT
* to indicate an Overload Start procedure
* sends an OVERLOAD_START
* containing an Overload_Response.
* </pre>
*
* @see ETSI TS 103 497-2 TP_S1AP_MME_MNP_10
3236
3237
3238
3239
3240
3241
3242
3243
3244
3245
3246
3247
3248
3249
3250
3251
3252
3253
3254
3255
3256
3257
3258
3259
3260
3261
3262
3263
3264
3265
3266
3267
3268
3269
3270
3271
* @reference ETSI TS 136 413 V13.4.0 Clause 8.7.6.2¶1 and 9.1.8.13
*/
testcase TC_S1AP_MME_MNP_10() runs on S1AP system TestAdapter {
// Local variables
var S1AP v_s1ap_mme;
// Test control
if (not PICS_S1AP_MME_IUT) {
log("*** " & __SCOPE__ & ": ERROR: 'PICS_S1AP_MME_IUT' shall be set to true for executing the TC. ***");
stop;
}
// Test component direct information
f_cf_S1AP_MME_Up(v_s1ap_mme);
// Start
v_s1ap_mme.start(f_TC_S1AP_MME_MNP_10());
// synchronize PTC on 1 sychronization points
f_serverSyncNClientsAndStop(1, {c_prDone, c_tbDone, c_poDone});
f_cf_Down();
} // End of testcase TC_S1AP_MME_MNP_10
/**
* @desc Verify that the IUT can send an OVERLOAD_STOP to indicate an Overload Stop procedure.
* <pre>
* Pics Selection: A.4/6.7
* Configuration: CF_S1-MME
* Ensure that the IUT
* to indicate an Overload Stop procedure
* sends an OVERLOAD_STOP
* containing an Overload_Response.
* </pre>
*
* @see ETSI TS 103 497-2 TP_S1AP_MME_MNP_11
3273
3274
3275
3276
3277
3278
3279
3280
3281
3282
3283
3284
3285
3286
3287
3288
3289
3290
3291
3292
3293
3294
3295
3296
3297
* @reference ETSI TS 136 413 V13.4.0 Clause 8.7.7.2¶1 and 9.1.8.14
*/
testcase TC_S1AP_MME_MNP_11() runs on S1AP system TestAdapter {
// Local variables
var S1AP v_s1ap_mme;
// Test control
if (not PICS_S1AP_MME_IUT) {
log("*** " & __SCOPE__ & ": ERROR: 'PICS_S1AP_MME_IUT' shall be set to true for executing the TC. ***");
stop;
}
// Test component direct information
f_cf_S1AP_MME_Up(v_s1ap_mme);
// Start
v_s1ap_mme.start(f_TC_S1AP_MME_MNP_11());
// synchronize PTC on 1 sychronization points
f_serverSyncNClientsAndStop(1, {c_prDone, c_tbDone, c_poDone});
f_cf_Down();
} // End of testcase TC_S1AP_MME_MNP_11
} // End of group Management_group
/**
* @desc S1 CDMA 2000 tunnelling group group
* @see ETSI TS 103 497-2 Clause 5.2.2.2.8 S1 CDMA 2000 tunnelling group group
*/
group S1_CDMA_2000_tunelling_group {
/**
* @desc Verify that the IUT can send a DOWNLINK_S1_CDMA2000_TUNNELLING.
* <pre>
* Ensure that the IUT
* to indicate a CDMA2000 signalling event
* sends a DOWNLINK_S1_CDMA2000_TUNNELLING
* containing an MME_UE_S1AP_ID
* containing an eNB_UE_S1AP_ID
* not containing an E-RABs_Subject_to_Forwarding_Lis
* containing a CDMA2000_HO_type
* containing a CDMA2000_PDU.
* </pre>
*
* @see ETSI TS 103 497-2 TP_S1AP_MME_STP_01
3322
3323
3324
3325
3326
3327
3328
3329
3330
3331
3332
3333
3334
3335
3336
3337
3338
3339
3340
3341
3342
3343
3344
3345
3346
3347
3348
* @reference ETSI TS 136 413 V13.4.0 Clause 8.8.2.1¶1 and 9.1.9.1
*/
testcase TC_S1AP_MME_STP_01() runs on S1AP system TestAdapter {
// Local variables
var S1AP v_s1ap_mme;
// Test control
if (not PICS_S1AP_eNB_IUT) {
log("*** " & __SCOPE__ & ": ERROR: 'PICS_S1AP_eNB_IUT' shall be set to true for executing the TC. ***");
stop;
}
// Test component direct information
f_cf_S1AP_MME_Up(v_s1ap_mme);
// Start
v_s1ap_mme.start(f_TC_S1AP_MME_STP_01());
// synchronize PTC on 1 sychronization points
f_serverSyncNClientsAndStop(1, {c_prDone, c_tbDone, c_poDone});
f_cf_Down();
} // End of testcase TC_S1AP_MME_STP_01
} // End of group S1_CDMA_2000_tunelling_group
* @see ETSI TS 103 497-2 Clause 5.2.2.2.10 Trace group
*/
group Trace_group {
/**
* @desc Verify that the IUT can send a TRACE_START message to indicate Trace Start procedure.
* <pre>
* Pics Selection: A.4/9.1
* Ensure that the IUT
* to indicate a Trace Start procedure
* sends a TRACE_START
* containing an MME_UE_S1AP_ID
* containing an eNB_UE_S1AP_ID
* containing a Trace_Activation
* containing an E-UTRAN_Trace_ID
* containing a Interfaces_To_Trace
* indicating value ‘S1-MME’
* containing a Trace_depth
* indicating value ‘maximum’
* containing a Trace_Collection_Entity_IP_Address.
* </pre>
*
* @see ETSI TS 103 497-2 TP_S1AP_MME_TRP_01
3375
3376
3377
3378
3379
3380
3381
3382
3383
3384
3385
3386
3387
3388
3389
3390
3391
3392
3393
3394
3395
3396
3397
3398
3399
3400
3401
3402
3403
* @reference ETSI TS 136 413 V13.4.0 Clause 8.10.1.2¶1 and 9.1.11.1 and 9.2.1.4
*/
testcase TC_S1AP_MME_TRP_01() runs on S1AP system TestAdapter {
// Local variables
var S1AP v_s1ap_mme;
// Test control
if (not PICS_S1AP_MME_IUT) {
log("*** " & __SCOPE__ & ": ERROR: 'PICS_S1AP_MME_IUT' shall be set to true for executing the TC. ***");
stop;
}
// Test component direct information
f_cf_S1AP_MME_Up(v_s1ap_mme);
// Start
v_s1ap_mme.start(f_TC_S1AP_MME_TRP_01());
// synchronize PTC on 1 sychronization points
f_serverSyncNClientsAndStop(1, {c_prDone, c_tbDone, c_poDone});
f_cf_Down();
} // End of testcase TC_S1AP_MME_TRP_01
/**
* @desc Verify that the IUT can successfully process all mandatory IEs in a DEACTIVATE_TRACE.
* <pre>
* Pics Selection: A.4/9.3
* Ensure that the IUT
* to indicate a Deactivate Trace procedure
* sends a DEACTIVATE_TRACE
* containing an MME_UE_S1AP_ID
* containing an eNB_UE_S1AP_ID
* containing an E-UTRAN_Trace_ID.
* </pre>
*
* @see ETSI TS 103 497-2 TP_S1AP_MME_TRP_02
* @reference ETSI TS 136 413 V13.4.0 Clause 8.10.1.211 and 9.1.11.2
3415
3416
3417
3418
3419
3420
3421
3422
3423
3424
3425
3426
3427
3428
3429
3430
3431
3432
3433
3434
3435
3436
3437
3438
3439
*/
testcase TC_S1AP_MME_TRP_02() runs on S1AP system TestAdapter {
// Local variables
var S1AP v_s1ap_mme;
// Test control
if (not PICS_S1AP_MME_IUT) {
log("*** " & __SCOPE__ & ": ERROR: 'PICS_S1AP_MME_IUT' shall be set to true for executing the TC. ***");
stop;
}
// Test component direct information
f_cf_S1AP_MME_Up(v_s1ap_mme);
// Start
v_s1ap_mme.start(f_TC_S1AP_MME_TRP_02());
// synchronize PTC on 1 sychronization points
f_serverSyncNClientsAndStop(1, {c_prDone, c_tbDone, c_poDone});
f_cf_Down();
} // End of testcase TC_S1AP_MME_TRP_02
} // End of goup Trace_group
/**
* @see ETSI TS 103 497-2 Clause 5.2.2.2.11 Location reporting group
*/
group Location_reporting_group {
/**
* @desc Verify that the IUT can send a LOCATION_REPORTING_CONTROL.
* <pre>
* Pics Selection: A.4/10.1 and A.4/10.3
* Ensure that the IUT
* to indicate a Location Reporting Control procedure
* sends a LOCATION_REPORTING_CONTROL
* containing an MME_UE_S1AP_ID
* containing an eNB_UE_S1AP_ID
* containing a Request_Type
* containing a Event_Type
* containing a Report_Area
* indicating ECGI.
* </pre>
*
* @see ETSI TS 103 497-2 TP_S1AP_MME_LRP_01
3464
3465
3466
3467
3468
3469
3470
3471
3472
3473
3474
3475
3476
3477
3478
3479
3480
3481
3482
3483
3484
3485
3486
3487
3488
3489
3490
3491
3492
* @reference ETSI TS 136 413 V13.4.0 Clause 8.11.1.2-1 and 9.1.12.1 and 9.1.12.3 and 9.2.1.16,34,38
*/
testcase TC_S1AP_MME_LRP_01() runs on S1AP system TestAdapter {
// Local variables
var S1AP v_s1ap_mme;
// Test control
if (not PICS_S1AP_MME_IUT) {
log("*** " & __SCOPE__ & ": ERROR: 'PICS_S1AP_MME_IUT' shall be set to true for executing the TC. ***");
stop;
}
// Test component direct information
f_cf_S1AP_MME_Up(v_s1ap_mme);
// Start
v_s1ap_mme.start(f_TC_S1AP_MME_LRP_01());
// synchronize PTC on 1 sychronization points
f_serverSyncNClientsAndStop(1, {c_prDone, c_tbDone, c_poDone});
f_cf_Down();
} // End of testcase TC_S1AP_MME_LRP_01
/**
* @desc Verify that the IUT can send a LOCATION_REPORTING_CONTROL and process all mandatory IEs in a LOCATION REPORT_FAILURE_INDICATION.
* <pre>
* Pics Selection: A.4/10.1 and A.4/10.3
* Ensure that the IUT
* to indicate a Location Reporting Control procedure
* sends a LOCATION_REPORTING_CONTROL
* containing an MME_UE_S1AP_ID
* containing an eNB_UE_S1AP_ID
* containing a Request_Type
* containing a Event_Type
* containing a Report_Area
* indicating ECGI
* receives a LOCATION_REPORT_FAILURE_INDICATION
* containing an MME_UE_S1AP_ID
* containing an eNB_UE_S1AP_ID
* containing a Cause
* indicating an appropriate cause value.
* </pre>
*
* @see ETSI TS 103 497-2 TP_S1AP_MME_LRP_02
3511
3512
3513
3514
3515
3516
3517
3518
3519
3520
3521
3522
3523
3524
3525
3526
3527
3528
3529
3530
3531
3532
3533
3534
3535
3536
3537
3538
3539
* @reference ETSI TS 136 413 V13.4.0 Clause 8.11.1.2-1 and 9.1.12.1 and 9.1.12.3 and 9.2.1.16,34,38
*/
testcase TC_S1AP_MME_LRP_02() runs on S1AP system TestAdapter {
// Local variables
var S1AP v_s1ap_mme;
// Test control
if (not PICS_S1AP_MME_IUT) {
log("*** " & __SCOPE__ & ": ERROR: 'PICS_S1AP_MME_IUT' shall be set to true for executing the TC. ***");
stop;
}
// Test component direct information
f_cf_S1AP_MME_Up(v_s1ap_mme);
// Start
v_s1ap_mme.start(f_TC_S1AP_MME_LRP_02());
// synchronize PTC on 1 sychronization points
f_serverSyncNClientsAndStop(1, {c_prDone, c_tbDone, c_poDone});
f_cf_Down();
} // End of testcase TC_S1AP_MME_LRP_02
} // End of group Location_reporting_group
/**
* @desc Warning message transmission group
* @see ETSI TS 103 497-2 Clause 5.2.2.2.12 Warning message transmission group
*/
group Warning_message_transmission_group {
/**
* @desc Verify that the IUT can send a WRITE-REPLACE_WARNING_REQUEST to indicate a Warning Message Transmission procedure.
* <pre>
* Ensure that the IUT
* to indicate a Warning Message Transmission procedure
* sends a WRITE-REPLACE_WARNING_REQUEST
* containing a Message_Identifier
* containing a Serial_Number
* containing a Repetition Period
* containing an Number_of_Broadcasts_Requested
* </pre>
*
* @see ETSI TS 103 497-2 TP_S1AP_MME_WTP_01
3559
3560
3561
3562
3563
3564
3565
3566
3567
3568
3569
3570
3571
3572
3573
3574
3575
3576
3577
3578
3579
3580
3581
3582
3583
3584
3585
3586
* @reference ETSI TS 136 413 V13.4.0 Clause 8.12.1.2-1 and 9.1.13.1 and 9.1.13.2
*/
testcase TC_S1AP_MME_WTP_01() runs on S1AP system TestAdapter {
// Local variables
var S1AP v_s1ap_mme;
// Test control
if (not PICS_S1AP_MME_IUT) {
log("*** " & __SCOPE__ & ": ERROR: 'PICS_S1AP_MME_IUT' shall be set to true for executing the TC. ***");
stop;
}
// Test component direct information
f_cf_S1AP_MME_Up(v_s1ap_mme);
// Start
v_s1ap_mme.start(f_TC_S1AP_MME_WTP_01());
// synchronize PTC on 1 sychronization points
f_serverSyncNClientsAndStop(1, {c_prDone, c_tbDone, c_poDone});
f_cf_Down();
} // End of testcase TC_S1AP_MME_WTP_01
/**
* @desc Verify that the IUT can send a KILL_REQUEST to cancel an already ongoing broadcast of a Warning Message Transmission procedure.
* <pre>
* Ensure that the IUT
* to indicate a cancellation of an ongoing Warning Message Transmission procedure
* sends a KILL_REQUEST
* containing a Message_Identifier
* containing a Serial_Number
* </pre>
*
* @see ETSI TS 103 497-2 TP_S1AP_MME_WTP_02
3597
3598
3599
3600
3601
3602
3603
3604
3605
3606
3607
3608
3609
3610
3611
3612
3613
3614
3615
3616
3617
3618
3619
3620
3621
3622
3623
3624
3625
* @reference ETSI TS 136 413 V13.4.0 Clause 8.12.2.2-1 and 9.1.13.3 and 9.1.13.4
*/
testcase TC_S1AP_MME_WTP_02() runs on S1AP system TestAdapter {
// Local variables
var S1AP v_s1ap_mme;
// Test control
if (not PICS_S1AP_MME_IUT) {
log("*** " & __SCOPE__ & ": ERROR: 'PICS_S1AP_MME_IUT' shall be set to true for executing the TC. ***");
stop;
}
// Test component direct information
f_cf_S1AP_MME_Up(v_s1ap_mme);
// Start
v_s1ap_mme.start(f_TC_S1AP_MME_WTP_02());
// synchronize PTC on 1 sychronization points
f_serverSyncNClientsAndStop(1, {c_prDone, c_tbDone, c_poDone});
f_cf_Down();
} // End of testcase TC_S1AP_MME_WTP_02
} // End of group Warning_message_transmission_group
/**
* @desc MME direct information transfer group
* @see ETSI TS 103 497-2 Clause 5.2.2.2.14 MME direct information transfer group
*/
group MME_direct_information_transfer_group {
/**
* @desc Verify that the IUT can send an MME_DIRECT_INFORMATION_TRANSFER to indicate an MME Configuration Transfer procedure.
* <pre>
* Configuration: CF_S1-MME
* Ensure that the IUT
* to indicate an MME Direct Information Transfer procedure,
* sends an MME_DIRECT_INFORMATION_TRANSFER
* containing a RIM
* containing a RIM_Transfer
* containing a RIM_Information.
* </pre>
*
* @see ETSI TS 103 497-2 TP_S1AP_MME_MIT_01
3645
3646
3647
3648
3649
3650
3651
3652
3653
3654
3655
3656
3657
3658
3659
3660
3661
3662
3663
3664
3665
3666
3667
3668
3669
3670
3671
3672
3673
3674
* @reference ETSI TS 136 413 V13.4.0 Clause 8.14.2.1 and 9.2.3.23
*/
testcase TC_S1AP_MME_MIT_01() runs on S1AP system TestAdapter {
// Local variables
var S1AP v_s1ap_mme;
// Test control
if (not PICS_S1AP_MME_IUT) {
log("*** " & __SCOPE__ & ": ERROR: 'PICS_S1AP_MME_IUT' shall be set to true for executing the TC. ***");
stop;
}
// Test component configuration
f_cf_S1AP_MME_Up(v_s1ap_mme);
// Start
v_s1ap_mme.start(f_TC_S1AP_MME_MIT_01());
// synchronize PTC on 1 sychronization points
f_serverSyncNClientsAndStop(1, {c_prDone, c_tbDone, c_poDone});
f_cf_Down();
} // End of testcase TC_S1AP_MME_MIT_01
} // End of group MME_direct_information_transfer_group
/**
* @desc MME configuration transfer
* @see ETSI TS 103 497-2 Clause 5.2.2.2.16 MME configuration transfer group
*/
group MME_configuration_transfer_group {
/**
* @desc Verify that the IUT can send an MME_CONFIGURATION_TRANSFER to indicate an MME Configuration Transfer procedure.
* <pre>
* Configuration: CF_S1-MME
* Ensure that the IUT
* to indicate an MME Configuration Transfer procedure,
* sends an MME_CONFIGURATION_TRANSFER
* containing a SON_Configuration_Transfer
* containing a Target_eNB-ID
* containing a Source_eNB-ID
* containing a SON_Information.
* </pre>
*
* @see ETSI TS 103 497-2 TP_S1AP_MME_MCT_01
* @reference ETSI TS 136 413 V13.4.0 Clause 8.16.2.1 and 9.1.17
3695
3696
3697
3698
3699
3700
3701
3702
3703
3704
3705
3706
3707
3708
3709
3710
3711
3712
3713
3714
3715
3716
3717
3718
3719
3720
3721
3722
*/
testcase TC_S1AP_MME_MCT_01() runs on S1AP system TestAdapter {
// Local variables
var S1AP v_s1ap_mme;
// Test control
if (not PICS_S1AP_MME_IUT) {
log("*** " & __SCOPE__ & ": ERROR: 'PICS_S1AP_MME_IUT' shall be set to true for executing the TC. ***");
stop;
}
// Test component configuration
f_cf_S1AP_MME_Up(v_s1ap_mme);
// Start
v_s1ap_mme.start(f_TC_S1AP_MME_MCT_01());
// synchronize PTC on 1 sychronization points
f_serverSyncNClientsAndStop(1, {c_prDone, c_tbDone, c_poDone});
f_cf_Down();
} // End of testcase TC_S1AP_MME_MCT_01
} // End of group MME_configuration_transfer_group
/**
* @desc LPPa transport group
* @see ETSI TS 103 497-2 Clause 5.2.2.2.17 LPPa transport group
*/
group LPPa_transport_group {
/**
* @desc Verify that the IUT can send a DOWNLINK_UE_ASSOCIATED_LPPA_TRANSPORT to indicate a LPPa Transport procedure
* using a UE associated signalling.
* <pre>
* Configuration: CF_S1-MME
* Ensure that the IUT
* to indicate a LPPa Transport procedure using a UE associated signalling,
* sends a DOWNLINK_UE_ASSOCIATED_LPPA_TRANSPORT
* containing an MME_UE_S1AP_ID
* containing an eNB_UE_S1AP_ID
* containing a Routing_ID
* indicating a valid routing identifier value
* containing an LPPa-PDU.
* </pre>
*
* @see ETSI TS 103 497-2 TP_S1AP_MME_LPP_01
* @reference ETSI TS 136 413 V13.4.0 Clause 8.17.2.1 and 9.1.19.1
3745
3746
3747
3748
3749
3750
3751
3752
3753
3754
3755
3756
3757
3758
3759
3760
3761
3762
3763
3764
3765
3766
3767
3768
3769
3770
3771
3772
*/
testcase TC_S1AP_MME_LPP_01() runs on S1AP system TestAdapter {
// Local variables
var S1AP v_s1ap_mme;
// Test control
if (not PICS_S1AP_MME_IUT) {
log("*** " & __SCOPE__ & ": ERROR: 'PICS_S1AP_MME_IUT' shall be set to true for executing the TC. ***");
stop;
}
// Test component configuration
f_cf_S1AP_MME_Up(v_s1ap_mme);
// Start
v_s1ap_mme.start(f_TC_S1AP_MME_LPP_01());
// synchronize PTC on 1 sychronization points
f_serverSyncNClientsAndStop(1, {c_prDone, c_tbDone, c_poDone});
f_cf_Down();
} // End of testcase TC_S1AP_MME_LPP_01
/**
* @desc Verify that the IUT can send a DOWNLINK_UE_ASSOCIATED_LPPA_TRANSPORT to indicate a LPPa Transport procedure
* using a non-UE associated signalling.
* <pre>
* Configuration: CF_S1-MME
* Ensure that the IUT
* to indicate a LPPa Transport procedure using a UE associated signalling,
* sends a DOWNLINK_UE_ASSOCIATED_LPPA_TRANSPORT
* containing an MME_UE_S1AP_ID
* containing an eNB_UE_S1AP_ID
* containing a Routing_ID
* indicating a valid routing identifier value
* containing an LPPa-PDU.
* </pre>
*
* @see ETSI TS 103 497-2 TP_S1AP_MME_LPP_02
* @reference ETSI TS 136 413 V13.4.0 Clause 8.17.2.3 and 9.1.19.3
3787
3788
3789
3790
3791
3792
3793
3794
3795
3796
3797
3798
3799
3800
3801
3802
3803
3804
3805
3806
3807
3808
3809
3810
3811
3812
*/
testcase TC_S1AP_MME_LPP_02() runs on S1AP system TestAdapter {
// Local variables
var S1AP v_s1ap_mme;
// Test control
if (not PICS_S1AP_MME_IUT) {
log("*** " & __SCOPE__ & ": ERROR: 'PICS_S1AP_MME_IUT' shall be set to true for executing the TC. ***");
stop;
}
// Test component configuration
f_cf_S1AP_MME_Up(v_s1ap_mme);
// Start
v_s1ap_mme.start(f_TC_S1AP_MME_LPP_02());
// synchronize PTC on 1 sychronization points
f_serverSyncNClientsAndStop(1, {c_prDone, c_tbDone, c_poDone});
f_cf_Down();
} // End of testcase TC_S1AP_MME_LPP_02
} // End of group LPPa_transport_group
/**
* @desc Unknown, Unforseen and Erroneous Protocol Data
* @see ETSI TS 103 497-2 Clause 5.2.2.2.18 Unknown, Unforseen and Erroneous Protocol Data
*/
group Unknown_unforseen_errorneous_group {
3819
3820
3821
3822
3823
3824
3825
3826
3827
3828
3829
3830
3831
3832
3833
3834
3835
3836
3837
3838
3839
3840
3841
3842
3843
3844
3845
3846
3847
3848
3849
3850
3851
3852
3853
3854
3855
3856
3857
3858
3859
3860
3861
3862
3863
3864
3865
3866
3867
3868
3869
3870
3871
3872
3873
3874
3875
3876
3877
3878
3879
3880
3881
3882
3883
3884
3885
3886
3887
3888
3889
3890
3891
3892
3893
3894
3895
3896
3897
3898
3899
3900
3901
3902
3903
3904
3905
3906
3907
3908
3909
3910
3911
3912
3913
3914
3915
3916
3917
3918
3919
3920
3921
3922
3923
3924
3925
3926
3927
3928
3929
3930
3931
3932
3933
3934
3935
3936
3937
3938
3939
3940
3941
3942
3943
/**
* @desc Verify that the IUT rejects the procedure using Error Indication Procedure if message contains different types
* of received criticality information of the Procedure Code IE and include Procedure Code IE, Triggering Message IE
* and Procedure Criticality IE in the Criticality Diagnostics IE within ERROR_INDICATION.
* <pre>
* Pics Selection: A.4/2.8 and A.4/6.2.2 and A.4/17.2
* Configuration: CF_S1-MME
* Ensure that the IUT
* on receipt of a UE_CONTEXT_RESUME_REQUEST,
* with Criticality set to value from the Table 5
* containing an MME UE_S1AP_ID
* containing an eNB_UE_S1AP_ID
* containing an E-RAB_Failed_to_Resume_List
* containing an E-RAB_Failed_to_Resume_Item 1
* containing an E-RAB_ID
* containing a Cause
* indicating an appropriate value
* sends an ERROR_INDICATION
* containing a Criticality_Diagnostics
* containing a Procedure_Code
* containing a Triggering_Message
* containing a Procedure_Criticality.
* </pre>
*
* @see ETSI TS 103 497-2 TP_S1AP_MME_ERR_01
* @reference ETSI TS 136 413 V13.4.0 Clause 10.3.4.1¶8
*/
testcase TC_S1AP_MME_ERR_01() runs on S1AP system TestAdapter {
// Local variables
var S1AP v_s1ap_mme;
// Test control
if (not (PICS_S1AP_MME_IUT and PICS_S1AP_MME_INITIATION_ERROR_IND_ABSTRACT_SYNTAX_PROCEDURE)) {
log("*** " & __SCOPE__ & ": ERROR: 'PICS_S1AP_MME_IUT and PICS_S1AP_MME_INITIATION_ERROR_IND_ABSTRACT_SYNTAX_PROCEDURE' shall be set to true for executing the TC. ***");
stop;
}
// Test component configuration
f_cf_S1AP_MME_Up(v_s1ap_mme);
// Start
v_s1ap_mme.start(f_TC_S1AP_MME_ERR_01());
// synchronize PTC on 1 sychronization points
f_serverSyncNClientsAndStop(1, {c_prDone, c_tbDone, c_poDone});
f_cf_Down();
} // End of testcase TC_S1AP_MME_ERR_01
/**
* @desc Verify that the IUT rejects the procedure using Error Indication Procedure if message contains different types
* of received criticality information of the Procedure Code IE and include Procedure Code IE, Triggering Message IE
* and Procedure Criticality IE in the Criticality Diagnostics IE within ERROR_INDICATION.
* <pre>
* Pics Selection: A.4/2.8 and A.4/6.2.2 and A.4/17.2
* Configuration: CF_S1-MME
* Ensure that the IUT
* on receipt of a UE_CONTEXT_RESUME_REQUEST,
* with Criticality set to value from the Table 5
* containing an MME UE_S1AP_ID
* containing an eNB_UE_S1AP_ID
* containing an Unknown_ID
* containing Criticality
* indicating Reject or Ignore and Notify Sender
* containing an E-RAB_Failed_to_Resume_List
* containing an E-RAB_Failed_to_Resume_Item 1
* containing an E-RAB_ID
* containing a Cause
* indicating an appropriate value
* sends an UE_CONTEXT_RESUME_FAILURE
* containing an MME_UE_S1AP_ID
* containing an eNB_UE_S1AP_ID
* containing a Cause
* indicating appropriate Protocol Cause
* containing a Criticality_Diagnostics
* containing a Procedure_Code
* containing a Triggering_Message
* containing a Procedure_Criticality.
* </pre>
*
* @see ETSI TS 103 497-2 TP_S1AP_MME_ERR_02
* @reference ETSI TS 136 413 V13.4.0 Clause 10.3.4.2¶3(1st dashed line) and 13
*/
testcase TC_S1AP_MME_ERR_02() runs on S1AP system TestAdapter {
// Local variables
var S1AP v_s1ap_mme;
// Test control
if (not (PICS_S1AP_MME_IUT and PICS_S1AP_MME_INITIATION_ERROR_IND_ABSTRACT_SYNTAX_PROCEDURE)) {
log("*** " & __SCOPE__ & ": ERROR: 'PICS_S1AP_MME_IUT and PICS_S1AP_MME_INITIATION_ERROR_IND_ABSTRACT_SYNTAX_PROCEDURE' shall be set to true for executing the TC. ***");
stop;
}
// Test component configuration
f_cf_S1AP_MME_Up(v_s1ap_mme);
// Start
v_s1ap_mme.start(f_TC_S1AP_MME_ERR_02());
// synchronize PTC on 1 sychronization points
f_serverSyncNClientsAndStop(1, {c_prDone, c_tbDone, c_poDone});
f_cf_Down();
} // End of testcase TC_S1AP_MME_ERR_02
/**
* @desc Verify that the IUT rejects the procedure using Error Indication Procedure if message contains not comprehended
* IEs/IE groups marked with ‘Reject IE’ or ‘Ignore IE and Notify Sender’ and include Procedure Code IE,
* Triggering Message IE and Procedure Criticality IE and Information Element Criticality Diagnostics IE in the
* Criticality Diagnostics IE for each reported IEs/IE groups within ERROR_INDICATION.
* <pre>
* Pics Selection: A.4/2.8 and A.4/6.2.2 and A.4/17.2
* Configuration: CF_S1-MME
* Ensure that the IUT
* on receipt of a E-RAB_MODIFICATION_INDICATION,
* containing an MME UE_S1AP_ID
* containing an eNB_UE_S1AP_ID
* containing an Unknown_ID
* containing Criticality
* indicating Reject or Ignore and Notify Sender
* containing an E-RAB_to_be_Modified_List
* containing an E-RAB_to_be_Setup Item 1
* containing an E-RAB_ID
* containing a Transport_Layer_Address
* containing a DL_GTP-TEID
* sends an ERROR_INDICATION
* containing a Criticality_Diagnostics
* containing a Procedure_Code
* containing a Triggering_Message
* containing a Procedure_Criticality
* containing an Information Element Criticality_Diagnostics
* containing an IE_Criticality
* containing an IE_ID
* containing an IE_Type_of_Error.
* </pre>
*
* @see ETSI TS 103 497-2 TP_S1AP_MME_ERR_03
* @reference ETSI TS 136 413 V13.4.0 Clause 10.3.4.2¶4(2nd dashed line) and 14
3959
3960
3961
3962
3963
3964
3965
3966
3967
3968
3969
3970
3971
3972
3973
3974
3975
3976
3977
3978
3979
3980
3981
3982
*/
testcase TC_S1AP_MME_ERR_03() runs on S1AP system TestAdapter {
// Local variables
var S1AP v_s1ap_mme;
// Test control
if (not (PICS_S1AP_MME_IUT and PICS_S1AP_MME_INITIATION_ERROR_IND_ABSTRACT_SYNTAX_PROCEDURE)) {
log("*** " & __SCOPE__ & ": ERROR: 'PICS_S1AP_MME_IUT and PICS_S1AP_MME_INITIATION_ERROR_IND_ABSTRACT_SYNTAX_PROCEDURE' shall be set to true for executing the TC. ***");
stop;
}
// Test component configuration
f_cf_S1AP_MME_Up(v_s1ap_mme);
// Start
v_s1ap_mme.start(f_TC_S1AP_MME_ERR_03());
// synchronize PTC on 1 sychronization points
f_serverSyncNClientsAndStop(1, {c_prDone, c_tbDone, c_poDone});
f_cf_Down();
} // End of testcase TC_S1AP_MME_ERR_03
3983
3984
3985
3986
3987
3988
3989
3990
3991
3992
3993
3994
3995
3996
3997
3998
3999
4000
4001
4002
4003
4004
4005
4006
4007
4008
4009
4010
4011
4012
4013
4014
4015
4016
4017
4018
4019
4020
4021
4022
4023
4024
4025
4026
4027
4028
4029
4030
4031
4032
4033
4034
4035
4036
4037
/**
* @desc Verify that the IUT rejects the procedure if message not contains mandatory IEs/IE groups and include
* Information Element Criticality Diagnostics IE in the Criticality Diagnostics IE for each reported
* IEs/IE groups within response message for this procedure.
* <pre>
* Pics Selection: A.4/2.8 and A.4/6.2.2 and A.4/17.2
* Configuration: CF_S1-MME
* Ensure that the IUT
* on receipt of a UE_CONTEXT_RESUME_REQUEST,
* with Criticality set to value from the Table 5
* containing an MME UE_S1AP_ID
* not containing an eNB_UE_S1AP_ID
* containing an E-RAB_Failed_to_Resume_List
* containing an E-RAB_Failed_to_Resume_Item 1
* containing an E-RAB_ID
* containing a Cause
* indicating an appropriate value
* sends an UE_CONTEXT_RESUME_FAILURE
* containing an MME_UE_S1AP_ID
* containing an eNB_UE_S1AP_ID
* containing a Cause
* indicating appropriate Protocol Cause
* containing a Criticality_Diagnostics
* containing an Information Element Criticality_Diagnostics
* containing an IE_Criticality
* containing an IE_ID
* containing an IE_Type_of_Error.
* </pre>
*
* @see ETSI TS 103 497-2 TP_S1AP_MME_ERR_04
* @reference ETSI TS 136 413 V13.4.0 Clause 10.3.5¶3(1st dashed line) and 13
*/
testcase TC_S1AP_MME_ERR_04() runs on S1AP system TestAdapter {
// Local variables
var S1AP v_s1ap_mme;
// Test control
if (not (PICS_S1AP_MME_IUT and PICS_S1AP_MME_INITIATION_ERROR_IND_ABSTRACT_SYNTAX_PROCEDURE)) {
log("*** " & __SCOPE__ & ": ERROR: 'PICS_S1AP_MME_IUT and PICS_S1AP_MME_INITIATION_ERROR_IND_ABSTRACT_SYNTAX_PROCEDURE' shall be set to true for executing the TC. ***");
stop;
}
// Test component configuration
f_cf_S1AP_MME_Up(v_s1ap_mme);
// Start
v_s1ap_mme.start(f_TC_S1AP_MME_ERR_04());
// synchronize PTC on 1 sychronization points
f_serverSyncNClientsAndStop(1, {c_prDone, c_tbDone, c_poDone});
f_cf_Down();
} // End of testcase TC_S1AP_MME_ERR_04
4038
4039
4040
4041
4042
4043
4044
4045
4046
4047
4048
4049
4050
4051
4052
4053
4054
4055
4056
4057
4058
4059
4060
4061
4062
4063
4064
4065
4066
4067
4068
4069
4070
4071
4072
4073
4074
4075
4076
4077
4078
4079
4080
4081
4082
4083
4084
4085
4086
4087
4088
4089
4090
4091
4092
4093
4094
4095
4096
4097
4098
4099
4100
4101
4102
4103
4104
4105
4106
4107
4108
4109
4110
4111
4112
4113
4114
4115
4116
4117
4118
4119
4120
4121
4122
4123
4124
4125
4126
4127
4128
4129
4130
4131
4132
4133
4134
4135
4136
4137
4138
4139
4140
4141
4142
4143
4144
4145
4146
4147
4148
4149
4150
4151
4152
4153
4154
4155
4156
4157
4158
4159
4160
4161
4162
4163
4164
4165
4166
4167
4168
4169
4170
4171
4172
4173
4174
4175
4176
4177
4178
4179
4180
4181
4182
4183
4184
4185
4186
4187
4188
4189
4190
/**
* @desc Verify that the IUT rejects the procedure using Error Indication Procedure if message not contains mandatory
* IEs/IE groups and include Procedure Code IE, Triggering Message IE and Procedure Criticality IE
* and Information Element Criticality Diagnostics IE in the Criticality Diagnostics IE for each
* reported IEs/IE groups within ERROR_INDICATION.
* <pre>
* Pics Selection: A.4/2.8 and A.4/6.2.2 and A.4/17.2
* Configuration: CF_S1-MME
* Ensure that the IUT
* on receipt of a E-RAB_MODIFICATION_INDICATION,
* containing an MME UE_S1AP_ID
* not containing an eNB_UE_S1AP_ID
* containing an E-RAB_to_be_Modified_List
* containing an E-RAB_to_be_Setup Item 1
* containing an E-RAB_ID
* containing a Transport_Layer_Address
* containing a DL_GTP-TEID
* sends an ERROR_INDICATION
* containing a Criticality_Diagnostics
* containing a Procedure_Code
* containing a Triggering_Message
* containing a Procedure_Criticality
* containing an Information Element Criticality_Diagnostics
* containing an IE_Criticality
* containing an IE_ID
* containing an IE_Type_of_Error.
* </pre>
*
* @see ETSI TS 103 497-2 TP_S1AP_MME_ERR_05
* @reference ETSI TS 136 413 V13.4.0 Clause 10.3.5¶4(2nd dashed line) and 14
*/
testcase TC_S1AP_MME_ERR_05() runs on S1AP system TestAdapter {
// Local variables
var S1AP v_s1ap_mme;
// Test control
if (not (PICS_S1AP_MME_IUT and PICS_S1AP_MME_INITIATION_ERROR_IND_ABSTRACT_SYNTAX_PROCEDURE)) {
log("*** " & __SCOPE__ & ": ERROR: 'PICS_S1AP_MME_IUT and PICS_S1AP_MME_INITIATION_ERROR_IND_ABSTRACT_SYNTAX_PROCEDURE' shall be set to true for executing the TC. ***");
stop;
}
// Test component configuration
f_cf_S1AP_MME_Up(v_s1ap_mme);
// Start
v_s1ap_mme.start(f_TC_S1AP_MME_ERR_05());
// synchronize PTC on 1 sychronization points
f_serverSyncNClientsAndStop(1, {c_prDone, c_tbDone, c_poDone});
f_cf_Down();
} // End of testcase TC_S1AP_MME_ERR_05
/**
* @desc Verify that the IUT rejects the procedure if message contains too many occurrances of the same IEs/IE groups
* with response message for this procedure and report the cause value
* ‘Abstract Syntax Error(Falsely Constructed Message)’.
* <pre>
* Pics Selection: A.4/2.8 and A.4/6.2.2 and A.4/17.2
* Configuration: CF_S1-MME
* Ensure that the IUT
* on receipt of a UE_CONTEXT_RESUME_REQUEST,
* with Criticality set to value from the Table 5
* containing an MME UE_S1AP_ID
* containing an eNB_UE_S1AP_ID
* containing an eNB_UE_S1AP_ID(same IE as already present)
* containing an E-RAB_Failed_to_Resume_List
* containing an E-RAB_Failed_to_Resume_Item 1
* containing an E-RAB_ID
* containing a Cause
* indicating an appropriate value
* sends an UE_CONTEXT_RESUME_FAILURE
* containing an MME_UE_S1AP_ID
* containing an eNB_UE_S1AP_ID
* containing a Cause
* indicating indicating ‘Abstract Syntax Error(Falsely Constructed Message)’.
* </pre>
*
* @see ETSI TS 103 497-2 TP_S1AP_MME_ERR_06
* @reference ETSI TS 136 413 V13.4.0 Clause 10.3.6¶2(1st dashed line)
*/
testcase TC_S1AP_MME_ERR_06() runs on S1AP system TestAdapter {
// Local variables
var S1AP v_s1ap_mme;
// Test control
if (not (PICS_S1AP_MME_IUT and PICS_S1AP_MME_INITIATION_ERROR_IND_ABSTRACT_SYNTAX_PROCEDURE)) {
log("*** " & __SCOPE__ & ": ERROR: 'PICS_S1AP_MME_IUT and PICS_S1AP_MME_INITIATION_ERROR_IND_ABSTRACT_SYNTAX_PROCEDURE' shall be set to true for executing the TC. ***");
stop;
}
// Test component configuration
f_cf_S1AP_MME_Up(v_s1ap_mme);
// Start
v_s1ap_mme.start(f_TC_S1AP_MME_ERR_06());
// synchronize PTC on 1 sychronization points
f_serverSyncNClientsAndStop(1, {c_prDone, c_tbDone, c_poDone});
f_cf_Down();
} // End of testcase TC_S1AP_MME_ERR_06
/**
* @desc Verify that the IUT terminate the procedure that does not have message to report unsuccessful outcome and
* message contains too many occurrances of the same IEs/IE groups and initiate Error Indication Procedure with
* cause value ‘Abstract Syntax Error(Falsely Constructed Message)’.
* <pre>
* Pics Selection: A.4/2.8 and A.4/6.2.2 and A.4/17.2
* Configuration: CF_S1-MME
* Ensure that the IUT
* on receipt of a E-RAB_MODIFICATION_INDICATION,
* containing an MME UE_S1AP_ID
* containing an eNB_UE_S1AP_ID
* containing an eNB_UE_S1AP_ID(same IE as already present)
* containing an E-RAB_to_be_Modified_List
* containing an E-RAB_to_be_Setup Item 1
* containing an E-RAB_ID
* containing a Transport_Layer_Address
* containing a DL_GTP-TEID
* sends an ERROR_INDICATION
* containing a Cause
* indicating indicating ‘Abstract Syntax Error(Falsely Constructed Message)’.
* </pre>
*
* @see ETSI TS 103 497-2 TP_S1AP_MME_ERR_07
* @reference ETSI TS 136 413 V13.4.0 Clause 10.3.6¶3(2nd dashed line)
*/
testcase TC_S1AP_MME_ERR_07() runs on S1AP system TestAdapter {
// Local variables
var S1AP v_s1ap_mme;
// Test control
if (not (PICS_S1AP_MME_IUT and PICS_S1AP_MME_INITIATION_ERROR_IND_ABSTRACT_SYNTAX_PROCEDURE)) {
log("*** " & __SCOPE__ & ": ERROR: 'PICS_S1AP_MME_IUT and PICS_S1AP_MME_INITIATION_ERROR_IND_ABSTRACT_SYNTAX_PROCEDURE' shall be set to true for executing the TC. ***");
stop;
}
// Test component configuration
f_cf_S1AP_MME_Up(v_s1ap_mme);
// Start
v_s1ap_mme.start(f_TC_S1AP_MME_ERR_07());
// synchronize PTC on 1 sychronization points
f_serverSyncNClientsAndStop(1, {c_prDone, c_tbDone, c_poDone});
f_cf_Down();
} // End of testcase TC_S1AP_MME_ERR_07
} // End of group Unknown_unforseen_errorneous_group