Newer
Older
*** Settings ***
Resource environment/variables.txt
Library REST ${VNFM_SCHEMA}://${VNFM_HOST}:${VNFM_PORT} ssl_verify=false
Library JSONLibrary
Library JSONSchemaLibrary schemas/
*** Test Cases ***
Post Individual VNF LCM OP occurrences - Method not implemented
... Test title: Post Individual VNF LCM OP occurrences - Method not implemented
... Test objective: The objective is to test that POST method is not implemented
... Pre-conditions: none
... Reference: Clause 5.4.13.3.1 - ETSI GS NFV-SOL 002 [2] v2.7.1
... Config ID: Config_prod_VE
... Applicability: none
... Post-Conditions: none
Post Individual VNF LCM OP occurrences
Check HTTP Response Status Code Is 405
Get status information about multiple VNF instances
[Documentation] Test ID: 6.3.5.12.2
... Test title: Get status information about multiple VNF instances
... Test objective: The objective is to test that this method retrieve status information about a VNF lifecycle management operation occurrence
... Pre-conditions: none
... Reference: Clause 5.4.13.3.2 - ETSI GS NFV-SOL 002 [2] v2.7.1
... Config ID: Config_prod_VE
... Applicability: none
... Post-Conditions: none
Get Individual VNF LCM OP occurrences
Check HTTP Response Status Code Is 200
Check HTTP Response Body Json Schema Is VnfLcmOpOcc
Check HTTP Response Body vnf LCM OpOCC content against VNF Descriptor
PUT status information about multiple VNF instances - Method not implemented
[Documentation] Test ID: 6.3.5.12.3
... Test title: PUT status information about multiple VNF instances - Method not implemented
... Test objective: The objective is to test that PUT method is not implemented
... Pre-conditions: none
... Reference: Clause 5.4.13.3.3 - ETSI GS NFV-SOL 002 [2] v2.7.1
... Config ID: Config_prod_VE
... Applicability: none
... Post-Conditions: none
PUT Individual VNF LCM OP occurrences
PATCH status information about multiple VNF instances - Method not implemented
[Documentation] Test ID: 6.3.5.12.4
... Test title: PATCH status information about multiple VNF instances - Method not implemented
... Test objective: The objective is to test that PATCH method is not implemented
... Pre-conditions: none
... Reference: Clause 5.4.13.3.4 - ETSI GS NFV-SOL 002 [2] v2.7.1
... Config ID: Config_prod_VE
... Applicability: none
... Post-Conditions: none
PATCH Individual VNF LCM OP occurrences
DELETE status information about multiple VNF instances - Method not implemented
[Documentation] Test ID: 6.3.5.12.5
... Test title: DELETE status information about multiple VNF instances - Method not implemented
... Test objective: The objective is to test that DELETE method is not implemented
... Pre-conditions: none
... Reference: Clause 5.4.13.3.5 - ETSI GS NFV-SOL 002 [2] v2.7.1
... Config ID: Config_prod_VE
... Applicability: none
... Post-Conditions: none
DELETE Individual VNF LCM OP occurrences