Commit 99b61786 authored by piscione's avatar piscione
Browse files

Fix on Test setup and test teardown of MEC040 TCs

parent f716a5f3
No related branches found
No related tags found
1 merge request!3Merge of TT027 branch into master
......@@ -2,10 +2,12 @@ Y''[Documentation] robot --outputdir ../../../outputs ./FederationEnablement.r
... Test Suite to validate the Federation Enablement API (FED) operations.
*** Settings ***
Resource environment/variables.txt
Resource ../../pics.txt
Resource ../../GenericKeywords.robot
Resource ../../../pics.txt
Resource ../../../GenericKeywords.robot
Library REST ${SCHEMA}://${HOST}:${PORT} ssl_verify=false
Library OperatingSystem
Library String
Test Setup Test Setup ${SYSTEM_ID_PLACEHOLDER} SystemInfo ${NO_ACTION}
......@@ -19,11 +21,11 @@ TC_MEC_MEC040_SRV_MEF_001_OK
... when requested by a MEC Orchestrator - No query parameters
... ETSI GS MEC 040 V3.1.1, clause 7.3.3.1, clause 5.2.2.2
... https://www.etsi.org/deliver/etsi_gs/mec/001_099/040/03.01.01_60/gs_mec040v030101p.pdf
[Setup] Test Setup ${None} SystemInfo ${REGISTER_ACTION}
[Setup] Register mutiple system Info and get system Ids SystemInfo SystemInfo2 SystemInfo3
Retrieve all system info resources
Check HTTP Response Status Code Is 200
Check HTTP Response Body Json Schema Is SystemInfoList
[Teardown] Test TearDown ${setup_response['body']['systemId']} ${None} ${REMOVE_ACTION}
[Teardown] Remove mutiple system Info ${SYSTEM_ID_1} ${SYSTEM_ID_2} ${SYSTEM_ID_3}
......@@ -33,13 +35,14 @@ TC_MEC_MEC040_SRV_MEF_001_OK_02
... when requested by a MEC Orchestrator - SystemId query parameters
... ETSI GS MEC 040 V3.1.1, clause 7.3.3.1, clause 5.2.2.2
... https://www.etsi.org/deliver/etsi_gs/mec/001_099/040/03.01.01_60/gs_mec040v030101p.pdf
#SystemId cannot be set by the requestor, so Test setup and test tear down are not applicable
[Setup] Register mutiple system Info and get system Ids SystemInfo SystemInfo2 SystemInfo3
Retrieve all system info resources with query params ${SYSTEM_ID_QUERY_PARAM}
Check HTTP Response Status Code Is 200
Check HTTP Response Body Json Schema Is SystemInfoList
FOR ${element} IN @{response['body']}
Should Be Equal As Strings ${element}[systemId] ${EXPECTED_SYSTEM_ID}
Should Be Equal As Strings ${element}[systemId] ${SYSTEM_ID_1}
END
[Teardown] Remove mutiple system Info ${SYSTEM_ID_1} ${SYSTEM_ID_2} ${SYSTEM_ID_3}
TC_MEC_MEC040_SRV_MEF_001_OK_03
[Documentation]
......@@ -47,21 +50,25 @@ TC_MEC_MEC040_SRV_MEF_001_OK_03
... when requested by a MEC Orchestrator - Multiple SystemId query parameters
... ETSI GS MEC 040 V3.1.1, clause 7.3.3.1, clause 5.2.2.2
... https://www.etsi.org/deliver/etsi_gs/mec/001_099/040/03.01.01_60/gs_mec040v030101p.pdf
#SystemId cannot be set by the requestor, so Test setup and test tear down are not applicable
[Setup] Register mutiple system Info and get system Ids SystemInfo SystemInfo2 SystemInfo3
Retrieve all system info resources with query params ${MULTIPLE_SYSTEM_ID_QUERY_PARAM}
Check HTTP Response Status Code Is 200
Check HTTP Response Body Json Schema Is SystemInfoList
FOR ${element} IN @{response['body']}
IF '''${element}[systemId]''' == '''${EXPECTED_SYSTEM_ID}'''
IF '''${element}[systemId]''' == '''${SYSTEM_ID_1}'''
${found_first_system_id} Set Variable ${TRUE}
END
IF '''${element}[systemId]''' == '''${EXPECTED_SYSTEM_ID2}'''
IF '''${element}[systemId]''' == '''${SYSTEM_ID_2}'''
${found_second_system_id} Set Variable ${TRUE}
END
END
Should Be True ${found_first_system_id}
Should Be True ${found_second_system_id}
[Teardown] Remove mutiple system Info ${SYSTEM_ID_1} ${SYSTEM_ID_2} ${SYSTEM_ID_3}
TC_MEC_MEC040_SRV_MEF_001_OK_04
[Documentation]
......@@ -69,11 +76,12 @@ TC_MEC_MEC040_SRV_MEF_001_OK_04
... when requested by a MEC Orchestrator - Empty SystemId query parameters
... ETSI GS MEC 040 V3.1.1, clause 7.3.3.1, clause 5.2.2.2
... https://www.etsi.org/deliver/etsi_gs/mec/001_099/040/03.01.01_60/gs_mec040v030101p.pdf
[Setup] Test Setup ${None} SystemInfo ${REGISTER_ACTION}
[Setup] Register mutiple system Info and get system Ids SystemInfo SystemInfo2 SystemInfo3
Retrieve all system info resources
Check HTTP Response Status Code Is 200
Check HTTP Response Body Json Schema Is SystemInfoList
[Teardown] Test TearDown ${setup_response['body']['systemId']} ${None} ${REMOVE_ACTION}
[Teardown] Remove mutiple system Info ${SYSTEM_ID_1} ${SYSTEM_ID_2} ${SYSTEM_ID_3}
TC_MEC_MEC040_SRV_MEF_001_OK_05
......@@ -82,7 +90,7 @@ TC_MEC_MEC040_SRV_MEF_001_OK_05
... when requested by a MEC Orchestrator - SystemName query parameters
... ETSI GS MEC 040 V3.1.1, clause 7.3.3.1, clause 5.2.2.2
... https://www.etsi.org/deliver/etsi_gs/mec/001_099/040/03.01.01_60/gs_mec040v030101p.pdf
[Setup] Test Setup ${None} SystemInfo ${REGISTER_ACTION}
[Setup] Register mutiple system Info and get system Ids SystemInfo SystemInfo2 SystemInfo3
${SYSTEM_NAME_VALUE} Get value entry from JSON file SystemInfo systemName
Retrieve all system info resources with query params ${SYSTEM_NAME_QUERY_PARAM}
......@@ -91,8 +99,7 @@ TC_MEC_MEC040_SRV_MEF_001_OK_05
FOR ${element} IN @{response['body']}
Should Be Equal As Strings ${element}[systemName] ${SYSTEM_NAME_VALUE}
END
[Teardown] Test TearDown ${setup_response['body']['systemId']} ${None} ${REMOVE_ACTION}
[Teardown] Remove mutiple system Info ${SYSTEM_ID_1} ${SYSTEM_ID_2} ${SYSTEM_ID_3}
TC_MEC_MEC040_SRV_MEF_001_OK_06
[Documentation]
......@@ -100,9 +107,9 @@ TC_MEC_MEC040_SRV_MEF_001_OK_06
... when requested by a MEC Orchestrator - Multiple SystemName query parameters
... ETSI GS MEC 040 V3.1.1, clause 7.3.3.1, clause 5.2.2.2
... https://www.etsi.org/deliver/etsi_gs/mec/001_099/040/03.01.01_60/gs_mec040v030101p.pdf
[Setup] Test Setup ${None} SystemInfo ${REGISTER_ACTION}
[Setup] Register mutiple system Info and get system Ids SystemInfo SystemInfo2 SystemInfo3
${SYSTEM_NAME_VALUE} Get value entry from JSON file SystemInfo systemName
${SYSTEM_NAME_VALUE_2} Get value entry from JSON file SystemInfo2 systemName
Retrieve all system info resources with query params ${MUTIPLE_SYSTEM_NAME_QUERY_PARAM}
Check HTTP Response Status Code Is 200
Check HTTP Response Body Json Schema Is SystemInfoList
......@@ -110,13 +117,13 @@ TC_MEC_MEC040_SRV_MEF_001_OK_06
IF '''${element}[systemName]''' == '''${SYSTEM_NAME_VALUE}'''
${found_sys_name_one} Set Variable ${TRUE}
END
IF '''${element}[systemName]''' == '''${EXPECTED_SYSTEM_NAME2}'''
IF '''${element}[systemName]''' == '''${SYSTEM_NAME_VALUE_2}'''
${found_sys_name_two} Set Variable ${TRUE}
END
END
Should Be True ${found_sys_name_one}
Should Be True ${found_sys_name_two}
[Teardown] Test TearDown ${setup_response['body']['systemId']} ${None} ${REMOVE_ACTION}
[Teardown] Remove mutiple system Info ${SYSTEM_ID_1} ${SYSTEM_ID_2} ${SYSTEM_ID_3}
......@@ -126,12 +133,12 @@ TC_MEC_MEC040_SRV_MEF_001_OK_07
... when requested by a MEC Orchestrator - Empty SystemName query parameters
... ETSI GS MEC 040 V3.1.1, clause 7.3.3.1, clause 5.2.2.2
... https://www.etsi.org/deliver/etsi_gs/mec/001_099/040/03.01.01_60/gs_mec040v030101p.pdf
[Setup] Test Setup ${None} SystemInfo ${REGISTER_ACTION}
[Setup] Register mutiple system Info and get system Ids SystemInfo SystemInfo2 SystemInfo3
Retrieve all system info resources with query params ${EMPTY_SYSTEM_NAME_QUERY_PARAM}
Check HTTP Response Status Code Is 200
Check HTTP Response Body Json Schema Is SystemInfoList
[Teardown] Test TearDown ${setup_response['body']['systemId']} ${None} ${REMOVE_ACTION}
[Teardown] Remove mutiple system Info ${SYSTEM_ID_1} ${SYSTEM_ID_2} ${SYSTEM_ID_3}
TC_MEC_MEC040_SRV_MEF_001_OK_08
......@@ -140,7 +147,7 @@ TC_MEC_MEC040_SRV_MEF_001_OK_08
... when requested by a MEC Orchestrator - systemProvider query parameters
... ETSI GS MEC 040 V3.1.1, clause 7.3.3.1, clause 5.2.2.2
... https://www.etsi.org/deliver/etsi_gs/mec/001_099/040/03.01.01_60/gs_mec040v030101p.pdf
[Setup] Test Setup ${None} SystemInfo ${REGISTER_ACTION}
[Setup] Register mutiple system Info and get system Ids SystemInfo SystemInfo2 SystemInfo3
${SYS_PROVIDER_VALUE} Get value entry from JSON file SystemInfo systemProvider
Retrieve all system info resources with query params ${SYSTEM_PROVIDER_QUERY_PARAM}
......@@ -149,7 +156,7 @@ TC_MEC_MEC040_SRV_MEF_001_OK_08
FOR ${element} IN @{response['body']}
Should Be Equal As Strings ${element}[systemProvider] ${SYS_PROVIDER_VALUE}
END
[Teardown] Test TearDown ${setup_response['body']['systemId']} ${None} ${REMOVE_ACTION}
[Teardown] Remove mutiple system Info ${SYSTEM_ID_1} ${SYSTEM_ID_2} ${SYSTEM_ID_3}
TC_MEC_MEC040_SRV_MEF_001_OK_09
......@@ -158,24 +165,24 @@ TC_MEC_MEC040_SRV_MEF_001_OK_09
... when requested by a MEC Orchestrator - Multiple systemProvider query parameters
... ETSI GS MEC 040 V3.1.1, clause 7.3.3.1, clause 5.2.2.2
... https://www.etsi.org/deliver/etsi_gs/mec/001_099/040/03.01.01_60/gs_mec040v030101p.pdf
##TODO complete
[Setup] Register mutiple system Info and get system Ids SystemInfo SystemInfo2 SystemInfo3
Retrieve all system info resources with query params ${MUTIPLE_SYS_PROVIDER_QUERY_PAR}
Check HTTP Response Status Code Is 200
Check HTTP Response Body Json Schema Is SystemInfoList
[Setup] Test Setup ${None} SystemInfo ${REGISTER_ACTION}
${SYS_PROVIDER_VALUE} Get value entry from JSON file SystemInfo systemProvider
${SYS_PROVIDER_VALUE_2} Get value entry from JSON file SystemInfo2 systemProvider
FOR ${element} IN @{response['body']}
IF '''${element}[systemProvider]''' == '''${SYS_PROVIDER_VALUE}'''
${sys_provider_found} Set Variable ${TRUE}
END
IF '''${element}[systemProvider]''' == '''${EXPECTED_SYSTEM_PROVIDER2}'''
IF '''${element}[systemProvider]''' == '''${SYS_PROVIDER_VALUE_2}'''
${sys_provider2_found} Set Variable ${TRUE}
END
END
Should Be True ${sys_provider_found}
Should Be True ${sys_provider2_found}
[Teardown] Test TearDown ${setup_response['body']['systemId']} ${None} ${REMOVE_ACTION}
[Teardown] Remove mutiple system Info ${SYSTEM_ID_1} ${SYSTEM_ID_2} ${SYSTEM_ID_3}
......@@ -185,14 +192,14 @@ TC_MEC_MEC040_SRV_MEF_001_OK_10
... when requested by a MEC Orchestrator - Empty systemProvider query parameters
... ETSI GS MEC 040 V3.1.1, clause 7.3.3.1, clause 5.2.2.2
... https://www.etsi.org/deliver/etsi_gs/mec/001_099/040/03.01.01_60/gs_mec040v030101p.pdf
[Setup] Test Setup ${None} SystemInfoEmptySystemProvider ${REGISTER_ACTION}
[Setup] Register mutiple system Info and get system Ids SystemInfo SystemInfo2 SystemInfo3
Retrieve all system info resources with query params ${EMPTY_SYSTEM_PROVIDER_QUERY_PARAM}
Check HTTP Response Status Code Is 200
Check HTTP Response Body Json Schema Is SystemInfoList
FOR ${element} IN @{response['body']}
Should Be Equal As Strings ${element}[systemProvider] ${EMPTY}
END
[Teardown] Test TearDown ${setup_response['body']['systemId']} ${None} ${REMOVE_ACTION}
[Teardown] Remove mutiple system Info ${SYSTEM_ID_1} ${SYSTEM_ID_2} ${SYSTEM_ID_3}
TC_MEC_MEC040_SRV_MEF_001_OK_11
......@@ -201,16 +208,17 @@ TC_MEC_MEC040_SRV_MEF_001_OK_11
... when requested by a MEC Orchestrator - Multiple query parameters
... ETSI GS MEC 040 V3.1.1, clause 7.3.3.1, clause 5.2.2.2
... https://www.etsi.org/deliver/etsi_gs/mec/001_099/040/03.01.01_60/gs_mec040v030101p.pdf
[Setup] Test Setup ${None} SystemInfo ${REGISTER_ACTION}
[Setup] Register mutiple system Info and get system Ids SystemInfo SystemInfo2 SystemInfo3
${SYS_NAME_VALUE} Get value entry from JSON file SystemInfo systemName
${SYS_ID} Get value entry from JSON file SystemInfo systemName
Retrieve all system info resources with query params ${FILTER_ON_SYSTEM_ID_AND_NAME}
Check HTTP Response Status Code Is 200
Check HTTP Response Body Json Schema Is SystemInfoList
${counterSystemId} Set Variable ${0}
${counterSystemName} Set Variable ${0}
FOR ${element} IN @{response['body']}
IF '''${element}[systemId]''' == '''${EXPECTED_SYSTEM_ID}'''
IF '''${element}[systemId]''' == '''${SYS_ID}'''
${counterSystemId}= set variable ${counterSystemId+1}
END
IF '''${element}[systemName]''' == '''${SYS_NAME_VALUE}'''
......@@ -220,7 +228,7 @@ TC_MEC_MEC040_SRV_MEF_001_OK_11
END
Should Be True '${counterSystemName}'>'0'
Should Be True '${counterSystemId}'>'0'
[Teardown] Test TearDown ${setup_response['body']['systemId']} ${None} ${REMOVE_ACTION}
[Teardown] Remove mutiple system Info ${SYSTEM_ID_1} ${SYSTEM_ID_2} ${SYSTEM_ID_3}
TC_MEC_MEC040_SRV_MEF_001_NF_01
......@@ -229,11 +237,11 @@ TC_MEC_MEC040_SRV_MEF_001_NF_01
... when selection is not applicable - SystemId
... ETSI GS MEC 040 V3.1.1, clause 7.3.3.1, clause 5.2.2.2
... https://www.etsi.org/deliver/etsi_gs/mec/001_099/040/03.01.01_60/gs_mec040v030101p.pdf
[Setup] Test Setup ${NOT_EXT_SYSTEM_ID_QUERY_PARAM} ${None} ${REMOVE_ACTION}
[Setup] Remove specific system info resource ${NOT_EXT_SYSTEM_ID_QUERY_PARAM}
Retrieve all system info resources with query params ${NOT_EXT_SYSTEM_ID_QUERY_PARAM}
Check HTTP Response Status Code Is 404
TP_MEC_MEC040_SRV_MEF_001_NF_02
TC_MEC_MEC040_SRV_MEF_001_NF_02
[Documentation]
... Check that the IUT responds with an error
... when selection is not applicable - SystemName
......@@ -278,7 +286,7 @@ TC_MEC_MEC040_SRV_MEF_002_OK
Should Be Equal As Strings ${response['body']['systemName']} ${SYS_NAME_VALUE}
Should Be Equal As Strings ${response['body']['systemProvider']} ${SYS_NAME_PROVIDER}
[Teardown] Test TearDown ${response['body']['systemId']} ${None} ${REMOVE_ACTION}
[Teardown] Remove specific system info resource ${response['body']['systemId']}
......@@ -306,10 +314,12 @@ TC_MEC_MEC040_SRV_MEF_003_OK
... when requested by a MEC Orchestrator
... ETSI GS MEC 040 V3.1.1, clause 7.4.3.1, clause 5.2.2.1.1
... https://www.etsi.org/deliver/etsi_gs/mec/001_099/040/03.01.01_60/gs_mec040v030101p.pdf
## No test setup and teardown applicable because systemId is generated by IUT
Retrieve specific system info resource ${EXPECTED_SYSTEM_ID}
[Setup] Register mutiple system Info and get system Ids SystemInfo SystemInfo2 SystemInfo3
Retrieve specific system info resource ${SYSTEM_ID_1}
Check HTTP Response Status Code Is 200
Check HTTP Response Body Json Schema Is SystemInfo
[Teardown] Remove mutiple system Info ${SYSTEM_ID_1} ${SYSTEM_ID_2} ${SYSTEM_ID_3}
TC_MEC_MEC040_SRV_MEF_003_NF
[Documentation]
......@@ -317,7 +327,7 @@ TC_MEC_MEC040_SRV_MEF_003_NF
... when it receives a request for returning a systemInfo referred with a wrong systemId
... ETSI GS MEC 040 V3.1.1, clause 7.4.3.1, clause 5.2.2.1.1
... https://www.etsi.org/deliver/etsi_gs/mec/001_099/040/03.01.01_60/gs_mec040v030101p.pdf
[Setup] Test Setup ${NOT_EXISTING_SYSTEM_ID} ${None} ${REMOVE_ACTION}
[Setup] Remove specific system info resource ${NOT_EXISTING_SYSTEM_ID}
Retrieve specific system info resource ${NOT_EXISTING_SYSTEM_ID}
Check HTTP Response Status Code Is 404
......@@ -336,12 +346,12 @@ TC_MEC_MEC040_SRV_MEF_004_OK_01
... Check that the IUT updates the systemInfo when requested by a MEC Orchestrator
... ETSI GS MEC 040 V3.1.1, clause clause 7.4.3.3, clause 5.2.2.1.2
... https://www.etsi.org/deliver/etsi_gs/mec/001_099/040/03.01.01_60/gs_mec040v030101p.pdf
[Setup] Test Setup ${None} SystemInfo ${REGISTER_ACTION}
[Setup] Register mutiple system Info and get system Ids SystemInfo SystemInfo2 SystemInfo3
${SYS_PROVIDER} Get value entry from JSON file SystemInfoUpdate endpoint
Update specific system info resource ${setup_response['body']['systemId']} SystemInfoUpdate
Update specific system info resource ${SYSTEM_ID_1} SystemInfoUpdate
Check HTTP Response Status Code Is 200
Should Be Equal As Strings ${response['body']['systemProvider']} ${SYS_PROVIDER}
[Teardown] Test TearDown ${setup_response['body']['systemId']} ${None} ${REMOVE_ACTION}
[Teardown] Remove mutiple system Info ${SYSTEM_ID_1} ${SYSTEM_ID_2} ${SYSTEM_ID_3}
TC_MEC_MEC040_SRV_MEF_004_OK_02
......@@ -349,12 +359,12 @@ TC_MEC_MEC040_SRV_MEF_004_OK_02
... Check that the IUT updates the systemInfo when requested by a MEC Orchestrator
... ETSI GS MEC 040 V3.1.1, clause clause 7.4.3.3, clause 5.2.2.1.2
... https://www.etsi.org/deliver/etsi_gs/mec/001_099/040/03.01.01_60/gs_mec040v030101p.pdf
[Setup] Test Setup ${None} SystemInfo ${REGISTER_ACTION}
Update specific system info resource ${setup_response['body']['systemId']} SystemInfoUpdate2
[Setup] Register mutiple system Info and get system Ids SystemInfo SystemInfo2 SystemInfo3
Update specific system info resource ${SYSTEM_ID_1} SystemInfoUpdate2
${SYS_NAME} Get value entry from JSON file SystemInfoUpdate2 systemName
Check HTTP Response Status Code Is 200
Should Be Equal As Strings ${response['body']['systemName']} ${SYS_NAME}
[Teardown] Test TearDown ${setup_response['body']['systemId']} ${None} ${REMOVE_ACTION}
[Teardown] Remove mutiple system Info ${SYSTEM_ID_1} ${SYSTEM_ID_2} ${SYSTEM_ID_3}
......@@ -363,15 +373,15 @@ TC_MEC_MEC040_SRV_MEF_004_OK_03
... Check that the IUT updates the systemInfo when requested by a MEC Orchestrator
... ETSI GS MEC 040 V3.1.1, clause clause 7.4.3.3, clause 5.2.2.1.2
... https://www.etsi.org/deliver/etsi_gs/mec/001_099/040/03.01.01_60/gs_mec040v030101p.pdf
[Setup] Test Setup ${None} SystemInfo ${REGISTER_ACTION}
Update specific system info resource ${setup_response['body']['systemId']} SystemInfoUpdate3
[Setup] Register mutiple system Info and get system Ids SystemInfo SystemInfo2 SystemInfo3
Update specific system info resource ${SYSTEM_ID_1} SystemInfoUpdate3
Check HTTP Response Status Code Is 200
${SYS_NAME} Get value entry from JSON file SystemInfoUpdate3 systemName
${SYS_PROVIDER} Get value entry from JSON file SystemInfoUpdate3 endpoint
Should Be Equal As Strings ${response['body']['systemName']} ${SYS_NAME}
Should Be Equal As Strings ${response['body']['systemProvider']} ${SYS_PROVIDER}
[Teardown] Test TearDown ${setup_response['body']['systemId']} ${None} ${REMOVE_ACTION}
[Teardown] Remove mutiple system Info ${SYSTEM_ID_1} ${SYSTEM_ID_2} ${SYSTEM_ID_3}
TC_MEC_MEC040_SRV_MEF_004_NF
......@@ -379,42 +389,46 @@ TC_MEC_MEC040_SRV_MEF_004_NF
... Check that the IUT responds with an error when requested to update an unknown systemInfo
... ETSI GS MEC 040 V3.1.1, clause clause 7.4.3.3, clause 5.2.2.1.2
... https://www.etsi.org/deliver/etsi_gs/mec/001_099/040/03.01.01_60/gs_mec040v030101p.pdf
[Setup] Test Setup ${NOT_EXISTING_SYSTEM_ID} ${None} ${REMOVE_ACTION}
[Setup] Remove specific system info resource ${NOT_EXISTING_SYSTEM_ID}
Update specific system info resource ${NOT_EXISTING_SYSTEM_ID} SystemInfoUpdate3
Check HTTP Response Status Code Is 404
##TODO double check the corresponding TP
#TC_MEC_MEC040_SRV_MEF_004_BR_01
#[Documentation]
#... Check that the IUT responds with an error when requested to update with an inconsistant URI
#... ETSI GS MEC 040 V3.1.1, clause clause 7.4.3.3, clause 5.2.2.1.2
#... https://www.etsi.org/deliver/etsi_gs/mec/001_099/040/03.01.01_60/gs_mec040v030101p.pdf
#Update specific system info resource ${NOT_EXISTING_SYSTEM_ID} SystemInfoUpdate3
#Check HTTP Response Status Code Is 400
##TODO double check corresponding TP
TC_MEC_MEC040_SRV_MEF_004_BR_01
[Documentation]
... Check that the IUT responds with an error when requested to update with an inconsistant URI
... ETSI GS MEC 040 V3.1.1, clause clause 7.4.3.3, clause 5.2.2.1.2
... https://www.etsi.org/deliver/etsi_gs/mec/001_099/040/03.01.01_60/gs_mec040v030101p.pdf
Update specific system info resource ${NOT_EXISTING_SYSTEM_ID} SystemInfoUpdate3
Check HTTP Response Status Code Is 400
TC_MEC_MEC040_SRV_MEF_004_BR_02
[Documentation]
... Check that the IUT responds with an error when requested to update with no data provided
... ETSI GS MEC 040 V3.1.1, clause clause 7.4.3.3, clause 5.2.2.1.2
... https://www.etsi.org/deliver/etsi_gs/mec/001_099/040/03.01.01_60/gs_mec040v030101p.pdf
[Setup] Register mutiple system Info and get system Ids SystemInfo SystemInfo2 SystemInfo3
Update specific system info resource ${EXPECTED_SYSTEM_ID} SystemInfoUpdateBR
Check HTTP Response Status Code Is 400
[Teardown] Remove mutiple system Info ${SYSTEM_ID_1} ${SYSTEM_ID_2} ${SYSTEM_ID_3}
TC_MEC_MEC040_SRV_MEF_005_OK
[Documentation]
... Check that the IUT responds with an error when requested to delete an unknown systemInfo
... ETSI GS MEC 040 V3.1.1, clause clause 7.4.3.5, clause 5.2.2.1.3
... https://www.etsi.org/deliver/etsi_gs/mec/001_099/040/03.01.01_60/gs_mec040v030101p.pdf
[Setup] Test Setup ${None} SystemInfo ${REGISTER_ACTION}
Remove specific system info resource ${EXPECTED_SYSTEM_ID}
[Setup] Register mutiple system Info and get system Ids SystemInfo SystemInfo2 SystemInfo3
Remove specific system info resource ${SYSTEM_ID_1}
Check HTTP Response Status Code Is 204
[Teardown] Remove mutiple system Info ${SYSTEM_ID_1} ${SYSTEM_ID_2} ${SYSTEM_ID_3}
TC_MEC_MEC040_SRV_MEF_005_NF
[Documentation]
... Check that the IUT responds with an error when requested to delete an unknown systemInfo
... ETSI GS MEC 040 V3.1.1, clause clause 7.4.3.5, clause 5.2.2.1.3
... https://www.etsi.org/deliver/etsi_gs/mec/001_099/040/03.01.01_60/gs_mec040v030101p.pdf
[Setup] Test Setup ${NOT_EXISTING_SYSTEM_ID} ${None} ${REMOVE_ACTION}
[Setup] Remove specific system info resource ${NOT_EXISTING_SYSTEM_ID}
Remove specific system info resource ${NOT_EXISTING_SYSTEM_ID}
Check HTTP Response Status Code Is 404
......@@ -477,7 +491,7 @@ Retrieve all system info resources with query params
${output}= Output response
Set Suite Variable ${response} ${output}
Retrieve specific system info resource
Retrieve specific system info resource
[Arguments] ${SYSTEM_INFO_ID}
Should Be True ${PIC_MEC_PLAT} == 1
Should Be True ${PIC_SERVICES} == 1
......@@ -501,6 +515,27 @@ Register System Info
${output}= Output response
Set Suite Variable ${response} ${output}
Register mutiple system Info and get system Ids
[Arguments] ${content_01} ${content_02} ${content_03}
Register System Info ${content_01}
Set Suite Variable ${SYSTEM_ID_1} ${response}[body][systemId]
Register System Info ${content_02}
Set Suite Variable ${SYSTEM_ID_2} ${response}[body][systemId]
Register System Info ${content_03}
Set Suite Variable ${SYSTEM_ID_3} ${response}[body][systemId]
Remove mutiple system Info
[Arguments] ${sys_id_1} ${sys_id_2} ${sys_id_3}
Remove specific system info resource ${sys_id_1}
Remove specific system info resource ${sys_id_2}
Remove specific system info resource ${sys_id_3}
Register System Info and get system Id
[Arguments] ${content}
Register System Info ${content}
Set Suite Variable ${SYSTEM_ID} ${response}[body][systemId]
Update specific system info resource
[Arguments] ${systemId} ${content}
......
0% Loading or .
You are about to add 0 people to the discussion. Proceed with caution.
Finish editing this message first!
Please register or to comment