From 99b617866e1cb0a0e82534e9e1fbcef2a148f6b4 Mon Sep 17 00:00:00 2001 From: piscione Date: Mon, 20 May 2024 15:34:56 +0200 Subject: [PATCH] Fix on Test setup and test teardown of MEC040 TCs --- MEC040/SRV/MEF/FederationEnablement.robot | 157 +++++++++++++--------- 1 file changed, 96 insertions(+), 61 deletions(-) diff --git a/MEC040/SRV/MEF/FederationEnablement.robot b/MEC040/SRV/MEF/FederationEnablement.robot index ba14e44..f89104b 100644 --- a/MEC040/SRV/MEF/FederationEnablement.robot +++ b/MEC040/SRV/MEF/FederationEnablement.robot @@ -2,10 +2,12 @@ Y''[Documentation] robot --outputdir ../../../outputs ./FederationEnablement.r ... Test Suite to validate the Federation Enablement API (FED) operations. *** Settings *** Resource environment/variables.txt -Resource ../../pics.txt -Resource ../../GenericKeywords.robot +Resource ../../../pics.txt +Resource ../../../GenericKeywords.robot Library REST ${SCHEMA}://${HOST}:${PORT} ssl_verify=false Library OperatingSystem +Library String + Test Setup Test Setup ${SYSTEM_ID_PLACEHOLDER} SystemInfo ${NO_ACTION} @@ -19,11 +21,11 @@ TC_MEC_MEC040_SRV_MEF_001_OK ... when requested by a MEC Orchestrator - No query parameters ... ETSI GS MEC 040 V3.1.1, clause 7.3.3.1, clause 5.2.2.2 ... https://www.etsi.org/deliver/etsi_gs/mec/001_099/040/03.01.01_60/gs_mec040v030101p.pdf - [Setup] Test Setup ${None} SystemInfo ${REGISTER_ACTION} + [Setup] Register mutiple system Info and get system Ids SystemInfo SystemInfo2 SystemInfo3 Retrieve all system info resources Check HTTP Response Status Code Is 200 Check HTTP Response Body Json Schema Is SystemInfoList - [Teardown] Test TearDown ${setup_response['body']['systemId']} ${None} ${REMOVE_ACTION} + [Teardown] Remove mutiple system Info ${SYSTEM_ID_1} ${SYSTEM_ID_2} ${SYSTEM_ID_3} @@ -33,13 +35,14 @@ TC_MEC_MEC040_SRV_MEF_001_OK_02 ... when requested by a MEC Orchestrator - SystemId query parameters ... ETSI GS MEC 040 V3.1.1, clause 7.3.3.1, clause 5.2.2.2 ... https://www.etsi.org/deliver/etsi_gs/mec/001_099/040/03.01.01_60/gs_mec040v030101p.pdf - #SystemId cannot be set by the requestor, so Test setup and test tear down are not applicable + [Setup] Register mutiple system Info and get system Ids SystemInfo SystemInfo2 SystemInfo3 Retrieve all system info resources with query params ${SYSTEM_ID_QUERY_PARAM} Check HTTP Response Status Code Is 200 Check HTTP Response Body Json Schema Is SystemInfoList FOR ${element} IN @{response['body']} - Should Be Equal As Strings ${element}[systemId] ${EXPECTED_SYSTEM_ID} + Should Be Equal As Strings ${element}[systemId] ${SYSTEM_ID_1} END + [Teardown] Remove mutiple system Info ${SYSTEM_ID_1} ${SYSTEM_ID_2} ${SYSTEM_ID_3} TC_MEC_MEC040_SRV_MEF_001_OK_03 [Documentation] @@ -47,21 +50,25 @@ TC_MEC_MEC040_SRV_MEF_001_OK_03 ... when requested by a MEC Orchestrator - Multiple SystemId query parameters ... ETSI GS MEC 040 V3.1.1, clause 7.3.3.1, clause 5.2.2.2 ... https://www.etsi.org/deliver/etsi_gs/mec/001_099/040/03.01.01_60/gs_mec040v030101p.pdf - #SystemId cannot be set by the requestor, so Test setup and test tear down are not applicable + + [Setup] Register mutiple system Info and get system Ids SystemInfo SystemInfo2 SystemInfo3 + Retrieve all system info resources with query params ${MULTIPLE_SYSTEM_ID_QUERY_PARAM} Check HTTP Response Status Code Is 200 Check HTTP Response Body Json Schema Is SystemInfoList FOR ${element} IN @{response['body']} - IF '''${element}[systemId]''' == '''${EXPECTED_SYSTEM_ID}''' + IF '''${element}[systemId]''' == '''${SYSTEM_ID_1}''' ${found_first_system_id} Set Variable ${TRUE} END - IF '''${element}[systemId]''' == '''${EXPECTED_SYSTEM_ID2}''' + IF '''${element}[systemId]''' == '''${SYSTEM_ID_2}''' ${found_second_system_id} Set Variable ${TRUE} END END Should Be True ${found_first_system_id} Should Be True ${found_second_system_id} + [Teardown] Remove mutiple system Info ${SYSTEM_ID_1} ${SYSTEM_ID_2} ${SYSTEM_ID_3} + TC_MEC_MEC040_SRV_MEF_001_OK_04 [Documentation] @@ -69,11 +76,12 @@ TC_MEC_MEC040_SRV_MEF_001_OK_04 ... when requested by a MEC Orchestrator - Empty SystemId query parameters ... ETSI GS MEC 040 V3.1.1, clause 7.3.3.1, clause 5.2.2.2 ... https://www.etsi.org/deliver/etsi_gs/mec/001_099/040/03.01.01_60/gs_mec040v030101p.pdf - [Setup] Test Setup ${None} SystemInfo ${REGISTER_ACTION} + [Setup] Register mutiple system Info and get system Ids SystemInfo SystemInfo2 SystemInfo3 + Retrieve all system info resources Check HTTP Response Status Code Is 200 Check HTTP Response Body Json Schema Is SystemInfoList - [Teardown] Test TearDown ${setup_response['body']['systemId']} ${None} ${REMOVE_ACTION} + [Teardown] Remove mutiple system Info ${SYSTEM_ID_1} ${SYSTEM_ID_2} ${SYSTEM_ID_3} TC_MEC_MEC040_SRV_MEF_001_OK_05 @@ -82,7 +90,7 @@ TC_MEC_MEC040_SRV_MEF_001_OK_05 ... when requested by a MEC Orchestrator - SystemName query parameters ... ETSI GS MEC 040 V3.1.1, clause 7.3.3.1, clause 5.2.2.2 ... https://www.etsi.org/deliver/etsi_gs/mec/001_099/040/03.01.01_60/gs_mec040v030101p.pdf - [Setup] Test Setup ${None} SystemInfo ${REGISTER_ACTION} + [Setup] Register mutiple system Info and get system Ids SystemInfo SystemInfo2 SystemInfo3 ${SYSTEM_NAME_VALUE} Get value entry from JSON file SystemInfo systemName Retrieve all system info resources with query params ${SYSTEM_NAME_QUERY_PARAM} @@ -91,8 +99,7 @@ TC_MEC_MEC040_SRV_MEF_001_OK_05 FOR ${element} IN @{response['body']} Should Be Equal As Strings ${element}[systemName] ${SYSTEM_NAME_VALUE} END - [Teardown] Test TearDown ${setup_response['body']['systemId']} ${None} ${REMOVE_ACTION} - + [Teardown] Remove mutiple system Info ${SYSTEM_ID_1} ${SYSTEM_ID_2} ${SYSTEM_ID_3} TC_MEC_MEC040_SRV_MEF_001_OK_06 [Documentation] @@ -100,9 +107,9 @@ TC_MEC_MEC040_SRV_MEF_001_OK_06 ... when requested by a MEC Orchestrator - Multiple SystemName query parameters ... ETSI GS MEC 040 V3.1.1, clause 7.3.3.1, clause 5.2.2.2 ... https://www.etsi.org/deliver/etsi_gs/mec/001_099/040/03.01.01_60/gs_mec040v030101p.pdf - [Setup] Test Setup ${None} SystemInfo ${REGISTER_ACTION} + [Setup] Register mutiple system Info and get system Ids SystemInfo SystemInfo2 SystemInfo3 ${SYSTEM_NAME_VALUE} Get value entry from JSON file SystemInfo systemName - + ${SYSTEM_NAME_VALUE_2} Get value entry from JSON file SystemInfo2 systemName Retrieve all system info resources with query params ${MUTIPLE_SYSTEM_NAME_QUERY_PARAM} Check HTTP Response Status Code Is 200 Check HTTP Response Body Json Schema Is SystemInfoList @@ -110,13 +117,13 @@ TC_MEC_MEC040_SRV_MEF_001_OK_06 IF '''${element}[systemName]''' == '''${SYSTEM_NAME_VALUE}''' ${found_sys_name_one} Set Variable ${TRUE} END - IF '''${element}[systemName]''' == '''${EXPECTED_SYSTEM_NAME2}''' + IF '''${element}[systemName]''' == '''${SYSTEM_NAME_VALUE_2}''' ${found_sys_name_two} Set Variable ${TRUE} END END Should Be True ${found_sys_name_one} Should Be True ${found_sys_name_two} - [Teardown] Test TearDown ${setup_response['body']['systemId']} ${None} ${REMOVE_ACTION} + [Teardown] Remove mutiple system Info ${SYSTEM_ID_1} ${SYSTEM_ID_2} ${SYSTEM_ID_3} @@ -126,12 +133,12 @@ TC_MEC_MEC040_SRV_MEF_001_OK_07 ... when requested by a MEC Orchestrator - Empty SystemName query parameters ... ETSI GS MEC 040 V3.1.1, clause 7.3.3.1, clause 5.2.2.2 ... https://www.etsi.org/deliver/etsi_gs/mec/001_099/040/03.01.01_60/gs_mec040v030101p.pdf - [Setup] Test Setup ${None} SystemInfo ${REGISTER_ACTION} + [Setup] Register mutiple system Info and get system Ids SystemInfo SystemInfo2 SystemInfo3 Retrieve all system info resources with query params ${EMPTY_SYSTEM_NAME_QUERY_PARAM} Check HTTP Response Status Code Is 200 Check HTTP Response Body Json Schema Is SystemInfoList - [Teardown] Test TearDown ${setup_response['body']['systemId']} ${None} ${REMOVE_ACTION} + [Teardown] Remove mutiple system Info ${SYSTEM_ID_1} ${SYSTEM_ID_2} ${SYSTEM_ID_3} TC_MEC_MEC040_SRV_MEF_001_OK_08 @@ -140,7 +147,7 @@ TC_MEC_MEC040_SRV_MEF_001_OK_08 ... when requested by a MEC Orchestrator - systemProvider query parameters ... ETSI GS MEC 040 V3.1.1, clause 7.3.3.1, clause 5.2.2.2 ... https://www.etsi.org/deliver/etsi_gs/mec/001_099/040/03.01.01_60/gs_mec040v030101p.pdf - [Setup] Test Setup ${None} SystemInfo ${REGISTER_ACTION} + [Setup] Register mutiple system Info and get system Ids SystemInfo SystemInfo2 SystemInfo3 ${SYS_PROVIDER_VALUE} Get value entry from JSON file SystemInfo systemProvider Retrieve all system info resources with query params ${SYSTEM_PROVIDER_QUERY_PARAM} @@ -149,7 +156,7 @@ TC_MEC_MEC040_SRV_MEF_001_OK_08 FOR ${element} IN @{response['body']} Should Be Equal As Strings ${element}[systemProvider] ${SYS_PROVIDER_VALUE} END - [Teardown] Test TearDown ${setup_response['body']['systemId']} ${None} ${REMOVE_ACTION} + [Teardown] Remove mutiple system Info ${SYSTEM_ID_1} ${SYSTEM_ID_2} ${SYSTEM_ID_3} TC_MEC_MEC040_SRV_MEF_001_OK_09 @@ -158,24 +165,24 @@ TC_MEC_MEC040_SRV_MEF_001_OK_09 ... when requested by a MEC Orchestrator - Multiple systemProvider query parameters ... ETSI GS MEC 040 V3.1.1, clause 7.3.3.1, clause 5.2.2.2 ... https://www.etsi.org/deliver/etsi_gs/mec/001_099/040/03.01.01_60/gs_mec040v030101p.pdf - ##TODO complete + [Setup] Register mutiple system Info and get system Ids SystemInfo SystemInfo2 SystemInfo3 Retrieve all system info resources with query params ${MUTIPLE_SYS_PROVIDER_QUERY_PAR} Check HTTP Response Status Code Is 200 Check HTTP Response Body Json Schema Is SystemInfoList - [Setup] Test Setup ${None} SystemInfo ${REGISTER_ACTION} ${SYS_PROVIDER_VALUE} Get value entry from JSON file SystemInfo systemProvider - + ${SYS_PROVIDER_VALUE_2} Get value entry from JSON file SystemInfo2 systemProvider + FOR ${element} IN @{response['body']} IF '''${element}[systemProvider]''' == '''${SYS_PROVIDER_VALUE}''' ${sys_provider_found} Set Variable ${TRUE} END - IF '''${element}[systemProvider]''' == '''${EXPECTED_SYSTEM_PROVIDER2}''' + IF '''${element}[systemProvider]''' == '''${SYS_PROVIDER_VALUE_2}''' ${sys_provider2_found} Set Variable ${TRUE} END END Should Be True ${sys_provider_found} Should Be True ${sys_provider2_found} - [Teardown] Test TearDown ${setup_response['body']['systemId']} ${None} ${REMOVE_ACTION} + [Teardown] Remove mutiple system Info ${SYSTEM_ID_1} ${SYSTEM_ID_2} ${SYSTEM_ID_3} @@ -185,14 +192,14 @@ TC_MEC_MEC040_SRV_MEF_001_OK_10 ... when requested by a MEC Orchestrator - Empty systemProvider query parameters ... ETSI GS MEC 040 V3.1.1, clause 7.3.3.1, clause 5.2.2.2 ... https://www.etsi.org/deliver/etsi_gs/mec/001_099/040/03.01.01_60/gs_mec040v030101p.pdf - [Setup] Test Setup ${None} SystemInfoEmptySystemProvider ${REGISTER_ACTION} + [Setup] Register mutiple system Info and get system Ids SystemInfo SystemInfo2 SystemInfo3 Retrieve all system info resources with query params ${EMPTY_SYSTEM_PROVIDER_QUERY_PARAM} Check HTTP Response Status Code Is 200 Check HTTP Response Body Json Schema Is SystemInfoList FOR ${element} IN @{response['body']} Should Be Equal As Strings ${element}[systemProvider] ${EMPTY} END - [Teardown] Test TearDown ${setup_response['body']['systemId']} ${None} ${REMOVE_ACTION} + [Teardown] Remove mutiple system Info ${SYSTEM_ID_1} ${SYSTEM_ID_2} ${SYSTEM_ID_3} TC_MEC_MEC040_SRV_MEF_001_OK_11 @@ -201,16 +208,17 @@ TC_MEC_MEC040_SRV_MEF_001_OK_11 ... when requested by a MEC Orchestrator - Multiple query parameters ... ETSI GS MEC 040 V3.1.1, clause 7.3.3.1, clause 5.2.2.2 ... https://www.etsi.org/deliver/etsi_gs/mec/001_099/040/03.01.01_60/gs_mec040v030101p.pdf - [Setup] Test Setup ${None} SystemInfo ${REGISTER_ACTION} + [Setup] Register mutiple system Info and get system Ids SystemInfo SystemInfo2 SystemInfo3 ${SYS_NAME_VALUE} Get value entry from JSON file SystemInfo systemName - + ${SYS_ID} Get value entry from JSON file SystemInfo systemName + Retrieve all system info resources with query params ${FILTER_ON_SYSTEM_ID_AND_NAME} Check HTTP Response Status Code Is 200 Check HTTP Response Body Json Schema Is SystemInfoList ${counterSystemId} Set Variable ${0} ${counterSystemName} Set Variable ${0} FOR ${element} IN @{response['body']} - IF '''${element}[systemId]''' == '''${EXPECTED_SYSTEM_ID}''' + IF '''${element}[systemId]''' == '''${SYS_ID}''' ${counterSystemId}= set variable ${counterSystemId+1} END IF '''${element}[systemName]''' == '''${SYS_NAME_VALUE}''' @@ -220,7 +228,7 @@ TC_MEC_MEC040_SRV_MEF_001_OK_11 END Should Be True '${counterSystemName}'>'0' Should Be True '${counterSystemId}'>'0' - [Teardown] Test TearDown ${setup_response['body']['systemId']} ${None} ${REMOVE_ACTION} + [Teardown] Remove mutiple system Info ${SYSTEM_ID_1} ${SYSTEM_ID_2} ${SYSTEM_ID_3} TC_MEC_MEC040_SRV_MEF_001_NF_01 @@ -229,11 +237,11 @@ TC_MEC_MEC040_SRV_MEF_001_NF_01 ... when selection is not applicable - SystemId ... ETSI GS MEC 040 V3.1.1, clause 7.3.3.1, clause 5.2.2.2 ... https://www.etsi.org/deliver/etsi_gs/mec/001_099/040/03.01.01_60/gs_mec040v030101p.pdf - [Setup] Test Setup ${NOT_EXT_SYSTEM_ID_QUERY_PARAM} ${None} ${REMOVE_ACTION} + [Setup] Remove specific system info resource ${NOT_EXT_SYSTEM_ID_QUERY_PARAM} Retrieve all system info resources with query params ${NOT_EXT_SYSTEM_ID_QUERY_PARAM} Check HTTP Response Status Code Is 404 -TP_MEC_MEC040_SRV_MEF_001_NF_02 +TC_MEC_MEC040_SRV_MEF_001_NF_02 [Documentation] ... Check that the IUT responds with an error ... when selection is not applicable - SystemName @@ -278,7 +286,7 @@ TC_MEC_MEC040_SRV_MEF_002_OK Should Be Equal As Strings ${response['body']['systemName']} ${SYS_NAME_VALUE} Should Be Equal As Strings ${response['body']['systemProvider']} ${SYS_NAME_PROVIDER} - [Teardown] Test TearDown ${response['body']['systemId']} ${None} ${REMOVE_ACTION} + [Teardown] Remove specific system info resource ${response['body']['systemId']} @@ -306,10 +314,12 @@ TC_MEC_MEC040_SRV_MEF_003_OK ... when requested by a MEC Orchestrator ... ETSI GS MEC 040 V3.1.1, clause 7.4.3.1, clause 5.2.2.1.1 ... https://www.etsi.org/deliver/etsi_gs/mec/001_099/040/03.01.01_60/gs_mec040v030101p.pdf - ## No test setup and teardown applicable because systemId is generated by IUT - Retrieve specific system info resource ${EXPECTED_SYSTEM_ID} + [Setup] Register mutiple system Info and get system Ids SystemInfo SystemInfo2 SystemInfo3 + Retrieve specific system info resource ${SYSTEM_ID_1} Check HTTP Response Status Code Is 200 Check HTTP Response Body Json Schema Is SystemInfo + [Teardown] Remove mutiple system Info ${SYSTEM_ID_1} ${SYSTEM_ID_2} ${SYSTEM_ID_3} + TC_MEC_MEC040_SRV_MEF_003_NF [Documentation] @@ -317,7 +327,7 @@ TC_MEC_MEC040_SRV_MEF_003_NF ... when it receives a request for returning a systemInfo referred with a wrong systemId ... ETSI GS MEC 040 V3.1.1, clause 7.4.3.1, clause 5.2.2.1.1 ... https://www.etsi.org/deliver/etsi_gs/mec/001_099/040/03.01.01_60/gs_mec040v030101p.pdf - [Setup] Test Setup ${NOT_EXISTING_SYSTEM_ID} ${None} ${REMOVE_ACTION} + [Setup] Remove specific system info resource ${NOT_EXISTING_SYSTEM_ID} Retrieve specific system info resource ${NOT_EXISTING_SYSTEM_ID} Check HTTP Response Status Code Is 404 @@ -336,12 +346,12 @@ TC_MEC_MEC040_SRV_MEF_004_OK_01 ... Check that the IUT updates the systemInfo when requested by a MEC Orchestrator ... ETSI GS MEC 040 V3.1.1, clause clause 7.4.3.3, clause 5.2.2.1.2 ... https://www.etsi.org/deliver/etsi_gs/mec/001_099/040/03.01.01_60/gs_mec040v030101p.pdf - [Setup] Test Setup ${None} SystemInfo ${REGISTER_ACTION} + [Setup] Register mutiple system Info and get system Ids SystemInfo SystemInfo2 SystemInfo3 ${SYS_PROVIDER} Get value entry from JSON file SystemInfoUpdate endpoint - Update specific system info resource ${setup_response['body']['systemId']} SystemInfoUpdate + Update specific system info resource ${SYSTEM_ID_1} SystemInfoUpdate Check HTTP Response Status Code Is 200 Should Be Equal As Strings ${response['body']['systemProvider']} ${SYS_PROVIDER} - [Teardown] Test TearDown ${setup_response['body']['systemId']} ${None} ${REMOVE_ACTION} + [Teardown] Remove mutiple system Info ${SYSTEM_ID_1} ${SYSTEM_ID_2} ${SYSTEM_ID_3} TC_MEC_MEC040_SRV_MEF_004_OK_02 @@ -349,12 +359,12 @@ TC_MEC_MEC040_SRV_MEF_004_OK_02 ... Check that the IUT updates the systemInfo when requested by a MEC Orchestrator ... ETSI GS MEC 040 V3.1.1, clause clause 7.4.3.3, clause 5.2.2.1.2 ... https://www.etsi.org/deliver/etsi_gs/mec/001_099/040/03.01.01_60/gs_mec040v030101p.pdf - [Setup] Test Setup ${None} SystemInfo ${REGISTER_ACTION} - Update specific system info resource ${setup_response['body']['systemId']} SystemInfoUpdate2 + [Setup] Register mutiple system Info and get system Ids SystemInfo SystemInfo2 SystemInfo3 + Update specific system info resource ${SYSTEM_ID_1} SystemInfoUpdate2 ${SYS_NAME} Get value entry from JSON file SystemInfoUpdate2 systemName Check HTTP Response Status Code Is 200 Should Be Equal As Strings ${response['body']['systemName']} ${SYS_NAME} - [Teardown] Test TearDown ${setup_response['body']['systemId']} ${None} ${REMOVE_ACTION} + [Teardown] Remove mutiple system Info ${SYSTEM_ID_1} ${SYSTEM_ID_2} ${SYSTEM_ID_3} @@ -363,15 +373,15 @@ TC_MEC_MEC040_SRV_MEF_004_OK_03 ... Check that the IUT updates the systemInfo when requested by a MEC Orchestrator ... ETSI GS MEC 040 V3.1.1, clause clause 7.4.3.3, clause 5.2.2.1.2 ... https://www.etsi.org/deliver/etsi_gs/mec/001_099/040/03.01.01_60/gs_mec040v030101p.pdf - [Setup] Test Setup ${None} SystemInfo ${REGISTER_ACTION} - Update specific system info resource ${setup_response['body']['systemId']} SystemInfoUpdate3 + [Setup] Register mutiple system Info and get system Ids SystemInfo SystemInfo2 SystemInfo3 + Update specific system info resource ${SYSTEM_ID_1} SystemInfoUpdate3 Check HTTP Response Status Code Is 200 ${SYS_NAME} Get value entry from JSON file SystemInfoUpdate3 systemName ${SYS_PROVIDER} Get value entry from JSON file SystemInfoUpdate3 endpoint Should Be Equal As Strings ${response['body']['systemName']} ${SYS_NAME} Should Be Equal As Strings ${response['body']['systemProvider']} ${SYS_PROVIDER} - [Teardown] Test TearDown ${setup_response['body']['systemId']} ${None} ${REMOVE_ACTION} + [Teardown] Remove mutiple system Info ${SYSTEM_ID_1} ${SYSTEM_ID_2} ${SYSTEM_ID_3} TC_MEC_MEC040_SRV_MEF_004_NF @@ -379,42 +389,46 @@ TC_MEC_MEC040_SRV_MEF_004_NF ... Check that the IUT responds with an error when requested to update an unknown systemInfo ... ETSI GS MEC 040 V3.1.1, clause clause 7.4.3.3, clause 5.2.2.1.2 ... https://www.etsi.org/deliver/etsi_gs/mec/001_099/040/03.01.01_60/gs_mec040v030101p.pdf - [Setup] Test Setup ${NOT_EXISTING_SYSTEM_ID} ${None} ${REMOVE_ACTION} + [Setup] Remove specific system info resource ${NOT_EXISTING_SYSTEM_ID} Update specific system info resource ${NOT_EXISTING_SYSTEM_ID} SystemInfoUpdate3 Check HTTP Response Status Code Is 404 -##TODO double check the corresponding TP -#TC_MEC_MEC040_SRV_MEF_004_BR_01 - #[Documentation] - #... Check that the IUT responds with an error when requested to update with an inconsistant URI - #... ETSI GS MEC 040 V3.1.1, clause clause 7.4.3.3, clause 5.2.2.1.2 - #... https://www.etsi.org/deliver/etsi_gs/mec/001_099/040/03.01.01_60/gs_mec040v030101p.pdf - #Update specific system info resource ${NOT_EXISTING_SYSTEM_ID} SystemInfoUpdate3 - #Check HTTP Response Status Code Is 400 +##TODO double check corresponding TP +TC_MEC_MEC040_SRV_MEF_004_BR_01 + [Documentation] + ... Check that the IUT responds with an error when requested to update with an inconsistant URI + ... ETSI GS MEC 040 V3.1.1, clause clause 7.4.3.3, clause 5.2.2.1.2 + ... https://www.etsi.org/deliver/etsi_gs/mec/001_099/040/03.01.01_60/gs_mec040v030101p.pdf + Update specific system info resource ${NOT_EXISTING_SYSTEM_ID} SystemInfoUpdate3 + Check HTTP Response Status Code Is 400 TC_MEC_MEC040_SRV_MEF_004_BR_02 [Documentation] ... Check that the IUT responds with an error when requested to update with no data provided ... ETSI GS MEC 040 V3.1.1, clause clause 7.4.3.3, clause 5.2.2.1.2 ... https://www.etsi.org/deliver/etsi_gs/mec/001_099/040/03.01.01_60/gs_mec040v030101p.pdf + [Setup] Register mutiple system Info and get system Ids SystemInfo SystemInfo2 SystemInfo3 Update specific system info resource ${EXPECTED_SYSTEM_ID} SystemInfoUpdateBR Check HTTP Response Status Code Is 400 + [Teardown] Remove mutiple system Info ${SYSTEM_ID_1} ${SYSTEM_ID_2} ${SYSTEM_ID_3} + TC_MEC_MEC040_SRV_MEF_005_OK [Documentation] ... Check that the IUT responds with an error when requested to delete an unknown systemInfo ... ETSI GS MEC 040 V3.1.1, clause clause 7.4.3.5, clause 5.2.2.1.3 ... https://www.etsi.org/deliver/etsi_gs/mec/001_099/040/03.01.01_60/gs_mec040v030101p.pdf - [Setup] Test Setup ${None} SystemInfo ${REGISTER_ACTION} - Remove specific system info resource ${EXPECTED_SYSTEM_ID} + [Setup] Register mutiple system Info and get system Ids SystemInfo SystemInfo2 SystemInfo3 + Remove specific system info resource ${SYSTEM_ID_1} Check HTTP Response Status Code Is 204 + [Teardown] Remove mutiple system Info ${SYSTEM_ID_1} ${SYSTEM_ID_2} ${SYSTEM_ID_3} TC_MEC_MEC040_SRV_MEF_005_NF [Documentation] ... Check that the IUT responds with an error when requested to delete an unknown systemInfo ... ETSI GS MEC 040 V3.1.1, clause clause 7.4.3.5, clause 5.2.2.1.3 ... https://www.etsi.org/deliver/etsi_gs/mec/001_099/040/03.01.01_60/gs_mec040v030101p.pdf - [Setup] Test Setup ${NOT_EXISTING_SYSTEM_ID} ${None} ${REMOVE_ACTION} + [Setup] Remove specific system info resource ${NOT_EXISTING_SYSTEM_ID} Remove specific system info resource ${NOT_EXISTING_SYSTEM_ID} Check HTTP Response Status Code Is 404 @@ -477,7 +491,7 @@ Retrieve all system info resources with query params ${output}= Output response Set Suite Variable ${response} ${output} - Retrieve specific system info resource +Retrieve specific system info resource [Arguments] ${SYSTEM_INFO_ID} Should Be True ${PIC_MEC_PLAT} == 1 Should Be True ${PIC_SERVICES} == 1 @@ -501,6 +515,27 @@ Register System Info ${output}= Output response Set Suite Variable ${response} ${output} +Register mutiple system Info and get system Ids + [Arguments] ${content_01} ${content_02} ${content_03} + Register System Info ${content_01} + Set Suite Variable ${SYSTEM_ID_1} ${response}[body][systemId] + Register System Info ${content_02} + Set Suite Variable ${SYSTEM_ID_2} ${response}[body][systemId] + Register System Info ${content_03} + Set Suite Variable ${SYSTEM_ID_3} ${response}[body][systemId] + + +Remove mutiple system Info + [Arguments] ${sys_id_1} ${sys_id_2} ${sys_id_3} + Remove specific system info resource ${sys_id_1} + Remove specific system info resource ${sys_id_2} + Remove specific system info resource ${sys_id_3} + +Register System Info and get system Id + [Arguments] ${content} + Register System Info ${content} + Set Suite Variable ${SYSTEM_ID} ${response}[body][systemId] + Update specific system info resource [Arguments] ${systemId} ${content} -- GitLab