Newer
Older
Y''[Documentation] robot --outputdir ../../../outputs ./FederationEnablement.robot
... Test Suite to validate the Federation Enablement API (FED) operations.
*** Settings ***
Resource environment/variables.txt
Resource ../../pics.txt
Resource ../../GenericKeywords.robot
Library REST ${SCHEMA}://${HOST}:${PORT} ssl_verify=false
Library OperatingSystem
Test Setup Test Setup ${SYSTEM_ID_PLACEHOLDER} SystemInfo ${NO_ACTION}
Test Teardown Test TearDown ${SYSTEM_ID_PLACEHOLDER} SystemInfo ${NO_ACTION}
*** Test Cases ***
[Documentation]
... Check that the IUT responds with a list of all available systemInfo
... when requested by a MEC Orchestrator - No query parameters
... ETSI GS MEC 040 V3.1.1, clause 7.3.3.1, clause 5.2.2.2
... https://www.etsi.org/deliver/etsi_gs/mec/001_099/040/03.01.01_60/gs_mec040v030101p.pdf
[Setup] Test Setup ${None} SystemInfo ${REGISTER_ACTION}
Retrieve all system info resources
Check HTTP Response Status Code Is 200
Check HTTP Response Body Json Schema Is SystemInfoList
[Teardown] Test TearDown ${setup_response['body']['systemId']} ${None} ${REMOVE_ACTION}
TC_MEC_MEC040_SRV_MEF_001_OK_02
[Documentation]
... Check that the IUT responds with a selection of all available systemInfo
... when requested by a MEC Orchestrator - SystemId query parameters
... ETSI GS MEC 040 V3.1.1, clause 7.3.3.1, clause 5.2.2.2
... https://www.etsi.org/deliver/etsi_gs/mec/001_099/040/03.01.01_60/gs_mec040v030101p.pdf
#SystemId cannot be set by the requestor, so Test setup and test tear down are not applicable
Retrieve all system info resources with query params ${SYSTEM_ID_QUERY_PARAM}
Check HTTP Response Status Code Is 200
Check HTTP Response Body Json Schema Is SystemInfoList
FOR ${element} IN @{response['body']}
Should Be Equal As Strings ${element}[systemId] ${EXPECTED_SYSTEM_ID}
END
TC_MEC_MEC040_SRV_MEF_001_OK_03
[Documentation]
... Check that the IUT responds with a selection of all available systemInfo
... when requested by a MEC Orchestrator - Multiple SystemId query parameters
... ETSI GS MEC 040 V3.1.1, clause 7.3.3.1, clause 5.2.2.2
... https://www.etsi.org/deliver/etsi_gs/mec/001_099/040/03.01.01_60/gs_mec040v030101p.pdf
#SystemId cannot be set by the requestor, so Test setup and test tear down are not applicable
Retrieve all system info resources with query params ${MULTIPLE_SYSTEM_ID_QUERY_PARAM}
Check HTTP Response Status Code Is 200
Check HTTP Response Body Json Schema Is SystemInfoList
FOR ${element} IN @{response['body']}
IF '''${element}[systemId]''' == '''${EXPECTED_SYSTEM_ID}'''
${found_first_system_id} Set Variable ${TRUE}
END
IF '''${element}[systemId]''' == '''${EXPECTED_SYSTEM_ID2}'''
${found_second_system_id} Set Variable ${TRUE}
Should Be True ${found_first_system_id}
Should Be True ${found_second_system_id}
TC_MEC_MEC040_SRV_MEF_001_OK_04
[Documentation]
... Check that the IUT responds with a selection of all available systemInfo
... when requested by a MEC Orchestrator - Empty SystemId query parameters
... ETSI GS MEC 040 V3.1.1, clause 7.3.3.1, clause 5.2.2.2
... https://www.etsi.org/deliver/etsi_gs/mec/001_099/040/03.01.01_60/gs_mec040v030101p.pdf
[Setup] Test Setup ${None} SystemInfo ${REGISTER_ACTION}
Retrieve all system info resources
Check HTTP Response Status Code Is 200
Check HTTP Response Body Json Schema Is SystemInfoList
[Teardown] Test TearDown ${setup_response['body']['systemId']} ${None} ${REMOVE_ACTION}
TC_MEC_MEC040_SRV_MEF_001_OK_05
[Documentation]
... Check that the IUT responds with a selection of all available systemInfo
... when requested by a MEC Orchestrator - SystemName query parameters
... ETSI GS MEC 040 V3.1.1, clause 7.3.3.1, clause 5.2.2.2
... https://www.etsi.org/deliver/etsi_gs/mec/001_099/040/03.01.01_60/gs_mec040v030101p.pdf
[Setup] Test Setup ${None} SystemInfo ${REGISTER_ACTION}
${SYSTEM_NAME_VALUE} Get value entry from JSON file SystemInfo systemName
Retrieve all system info resources with query params ${SYSTEM_NAME_QUERY_PARAM}
Check HTTP Response Status Code Is 200
Check HTTP Response Body Json Schema Is SystemInfoList
FOR ${element} IN @{response['body']}
Should Be Equal As Strings ${element}[systemName] ${SYSTEM_NAME_VALUE}
[Teardown] Test TearDown ${setup_response['body']['systemId']} ${None} ${REMOVE_ACTION}
TC_MEC_MEC040_SRV_MEF_001_OK_06
[Documentation]
... Check that the IUT responds with a selection of all available systemInfo
... when requested by a MEC Orchestrator - Multiple SystemName query parameters
... ETSI GS MEC 040 V3.1.1, clause 7.3.3.1, clause 5.2.2.2
... https://www.etsi.org/deliver/etsi_gs/mec/001_099/040/03.01.01_60/gs_mec040v030101p.pdf
[Setup] Test Setup ${None} SystemInfo ${REGISTER_ACTION}
${SYSTEM_NAME_VALUE} Get value entry from JSON file SystemInfo systemName
Retrieve all system info resources with query params ${MUTIPLE_SYSTEM_NAME_QUERY_PARAM}
Check HTTP Response Status Code Is 200
Check HTTP Response Body Json Schema Is SystemInfoList
FOR ${element} IN @{response['body']}
IF '''${element}[systemName]''' == '''${SYSTEM_NAME_VALUE}'''
${found_sys_name_one} Set Variable ${TRUE}
END
IF '''${element}[systemName]''' == '''${EXPECTED_SYSTEM_NAME2}'''
${found_sys_name_two} Set Variable ${TRUE}
END
END
Should Be True ${found_sys_name_one}
Should Be True ${found_sys_name_two}
[Teardown] Test TearDown ${setup_response['body']['systemId']} ${None} ${REMOVE_ACTION}
TC_MEC_MEC040_SRV_MEF_001_OK_07
[Documentation]
... Check that the IUT responds with a selection of all available systemInfo
... when requested by a MEC Orchestrator - Empty SystemName query parameters
... ETSI GS MEC 040 V3.1.1, clause 7.3.3.1, clause 5.2.2.2
... https://www.etsi.org/deliver/etsi_gs/mec/001_099/040/03.01.01_60/gs_mec040v030101p.pdf
[Setup] Test Setup ${None} SystemInfo ${REGISTER_ACTION}
Retrieve all system info resources with query params ${EMPTY_SYSTEM_NAME_QUERY_PARAM}
Check HTTP Response Status Code Is 200
Check HTTP Response Body Json Schema Is SystemInfoList
[Teardown] Test TearDown ${setup_response['body']['systemId']} ${None} ${REMOVE_ACTION}
TC_MEC_MEC040_SRV_MEF_001_OK_08
[Documentation]
... Check that the IUT responds with a selection of all available systemInfo
... when requested by a MEC Orchestrator - systemProvider query parameters
... ETSI GS MEC 040 V3.1.1, clause 7.3.3.1, clause 5.2.2.2
... https://www.etsi.org/deliver/etsi_gs/mec/001_099/040/03.01.01_60/gs_mec040v030101p.pdf
[Setup] Test Setup ${None} SystemInfo ${REGISTER_ACTION}
${SYS_PROVIDER_VALUE} Get value entry from JSON file SystemInfo systemProvider
Retrieve all system info resources with query params ${SYSTEM_PROVIDER_QUERY_PARAM}
Check HTTP Response Status Code Is 200
Check HTTP Response Body Json Schema Is SystemInfoList
FOR ${element} IN @{response['body']}
Should Be Equal As Strings ${element}[systemProvider] ${SYS_PROVIDER_VALUE}
END
[Teardown] Test TearDown ${setup_response['body']['systemId']} ${None} ${REMOVE_ACTION}
TC_MEC_MEC040_SRV_MEF_001_OK_09
[Documentation]
... Check that the IUT responds with a selection of all available systemInfo
... when requested by a MEC Orchestrator - Multiple systemProvider query parameters
... ETSI GS MEC 040 V3.1.1, clause 7.3.3.1, clause 5.2.2.2
... https://www.etsi.org/deliver/etsi_gs/mec/001_099/040/03.01.01_60/gs_mec040v030101p.pdf
Retrieve all system info resources with query params ${MUTIPLE_SYS_PROVIDER_QUERY_PAR}
Check HTTP Response Status Code Is 200
Check HTTP Response Body Json Schema Is SystemInfoList
[Setup] Test Setup ${None} SystemInfo ${REGISTER_ACTION}
${SYS_PROVIDER_VALUE} Get value entry from JSON file SystemInfo systemProvider
FOR ${element} IN @{response['body']}
IF '''${element}[systemProvider]''' == '''${SYS_PROVIDER_VALUE}'''
${sys_provider_found} Set Variable ${TRUE}
END
IF '''${element}[systemProvider]''' == '''${EXPECTED_SYSTEM_PROVIDER2}'''
${sys_provider2_found} Set Variable ${TRUE}
END
END
Should Be True ${sys_provider_found}
Should Be True ${sys_provider2_found}
[Teardown] Test TearDown ${setup_response['body']['systemId']} ${None} ${REMOVE_ACTION}
TC_MEC_MEC040_SRV_MEF_001_OK_10
[Documentation]
... Check that the IUT responds with a selection of all available systemInfo
... when requested by a MEC Orchestrator - Empty systemProvider query parameters
... ETSI GS MEC 040 V3.1.1, clause 7.3.3.1, clause 5.2.2.2
... https://www.etsi.org/deliver/etsi_gs/mec/001_099/040/03.01.01_60/gs_mec040v030101p.pdf
[Setup] Test Setup ${None} SystemInfoEmptySystemProvider ${REGISTER_ACTION}
Retrieve all system info resources with query params ${EMPTY_SYSTEM_PROVIDER_QUERY_PARAM}
Check HTTP Response Status Code Is 200
Check HTTP Response Body Json Schema Is SystemInfoList
FOR ${element} IN @{response['body']}
Should Be Equal As Strings ${element}[systemProvider] ${EMPTY}
END
[Teardown] Test TearDown ${setup_response['body']['systemId']} ${None} ${REMOVE_ACTION}
TC_MEC_MEC040_SRV_MEF_001_OK_11
[Documentation]
... Check that the IUT responds with a selection of all available systemInfo
... when requested by a MEC Orchestrator - Multiple query parameters
... ETSI GS MEC 040 V3.1.1, clause 7.3.3.1, clause 5.2.2.2
... https://www.etsi.org/deliver/etsi_gs/mec/001_099/040/03.01.01_60/gs_mec040v030101p.pdf
[Setup] Test Setup ${None} SystemInfo ${REGISTER_ACTION}
${SYS_NAME_VALUE} Get value entry from JSON file SystemInfo systemName
Retrieve all system info resources with query params ${FILTER_ON_SYSTEM_ID_AND_NAME}
Check HTTP Response Status Code Is 200
Check HTTP Response Body Json Schema Is SystemInfoList
${counterSystemId} Set Variable ${0}
${counterSystemName} Set Variable ${0}
FOR ${element} IN @{response['body']}
IF '''${element}[systemId]''' == '''${EXPECTED_SYSTEM_ID}'''
${counterSystemId}= set variable ${counterSystemId+1}
END
IF '''${element}[systemName]''' == '''${SYS_NAME_VALUE}'''
${counterSystemName}= set variable ${counterSystemName+1}
END
${counterSystemName}= set variable ${counterSystemName+1}
END
Should Be True '${counterSystemName}'>'0'
Should Be True '${counterSystemId}'>'0'
[Teardown] Test TearDown ${setup_response['body']['systemId']} ${None} ${REMOVE_ACTION}
TC_MEC_MEC040_SRV_MEF_001_NF_01
[Documentation]
... Check that the IUT responds with an error
... when selection is not applicable - SystemId
... ETSI GS MEC 040 V3.1.1, clause 7.3.3.1, clause 5.2.2.2
... https://www.etsi.org/deliver/etsi_gs/mec/001_099/040/03.01.01_60/gs_mec040v030101p.pdf
[Setup] Test Setup ${NOT_EXT_SYSTEM_ID_QUERY_PARAM} ${None} ${REMOVE_ACTION}
Retrieve all system info resources with query params ${NOT_EXT_SYSTEM_ID_QUERY_PARAM}
Check HTTP Response Status Code Is 404
TP_MEC_MEC040_SRV_MEF_001_NF_02
[Documentation]
... Check that the IUT responds with an error
... when selection is not applicable - SystemName
... ETSI GS MEC 040 V3.1.1, clause 7.3.3.1, clause 5.2.2.2
... https://www.etsi.org/deliver/etsi_gs/mec/001_099/040/03.01.01_60/gs_mec040v030101p.pdf
##Test setup not applicable because systemInfo cannot be deleted by systemName
Retrieve all system info resources with query params ${NOT_EXT_SYSTEM_NAME_QUERY_PARAM}
Check HTTP Response Status Code Is 404
TC_MEC_MEC040_SRV_MEF_001_NF_03
[Documentation]
... Check that the IUT responds with an error
... when selection is not applicable - SystemProvider
... ETSI GS MEC 040 V3.1.1, clause 7.3.3.1, clause 5.2.2.2
... https://www.etsi.org/deliver/etsi_gs/mec/001_099/040/03.01.01_60/gs_mec040v030101p.pdf
##Test setup not applicable because systemInfo cannot be deleted by systemProvider
Retrieve all system info resources with query params ${NOT_EXT_SYS_PROVIDER_QUERY_PARAM}
Check HTTP Response Status Code Is 404
##TODO double check
TC_MEC_MEC040_SRV_MEF_001_BR
[Documentation]
... Check that the IUT responds with an error when request is malformed
... ETSI GS MEC 040 V3.1.1, clause 7.3.3.1, clause 5.2.2.2
... https://www.etsi.org/deliver/etsi_gs/mec/001_099/040/03.01.01_60/gs_mec040v030101p.pdf
Retrieve all system info resources wrong URL
#Check HTTP Response Status Code Is 400
TC_MEC_MEC040_SRV_MEF_002_OK
[Documentation]
... Check that the IUT creates a new systemInfo when requested by a MEC Orchestrator
... ETSI GS MEC 040 V3.1.1, clause 7.3.3.4, clause 5.2.2.1.1
... https://www.etsi.org/deliver/etsi_gs/mec/001_099/040/03.01.01_60/gs_mec040v030101p.pdf
##No test setup needed because the systemId is generated by IUT
Register System Info SystemInfo
Check HTTP Response Status Code Is 201
Check HTTP Response Body Json Schema Is SystemInfo
${SYS_NAME_VALUE} Get value entry from JSON file SystemInfo systemName
${SYS_NAME_PROVIDER} Get value entry from JSON file SystemInfo systemProvider
Should Be Equal As Strings ${response['body']['systemName']} ${SYS_NAME_VALUE}
Should Be Equal As Strings ${response['body']['systemProvider']} ${SYS_NAME_PROVIDER}
[Teardown] Test TearDown ${response['body']['systemId']} ${None} ${REMOVE_ACTION}
TC_MEC_MEC040_SRV_MEF_002_BR_01
[Documentation]
... Check that the IUT responds with an error on creating an existing systemInfo
... ETSI GS MEC 040 V3.1.1, clause 7.3.3.4, clause 5.2.2.1.1
... https://www.etsi.org/deliver/etsi_gs/mec/001_099/040/03.01.01_60/gs_mec040v030101p.pdf
Register System Info SystemInfoBR
Check HTTP Response Status Code Is 400
##TODO double check
TC_MEC_MEC040_SRV_MEF_002_BR_02
[Documentation]
... Check that the IUT responds with an error on providing inconsistent data
... ETSI GS MEC 040 V3.1.1, clause 7.3.3.4, clause 5.2.2.1.1
... https://www.etsi.org/deliver/etsi_gs/mec/001_099/040/03.01.01_60/gs_mec040v030101p.pdf
Register System Info SystemInfoBR
Check HTTP Response Status Code Is 400
TC_MEC_MEC040_SRV_MEF_003_OK
[Documentation]
... Check that the IUT responds with a selection of all available systemInfo
... when requested by a MEC Orchestrator
... ETSI GS MEC 040 V3.1.1, clause 7.4.3.1, clause 5.2.2.1.1
... https://www.etsi.org/deliver/etsi_gs/mec/001_099/040/03.01.01_60/gs_mec040v030101p.pdf
## No test setup and teardown applicable because systemId is generated by IUT
Retrieve specific system info resource ${EXPECTED_SYSTEM_ID}
Check HTTP Response Status Code Is 200
Check HTTP Response Body Json Schema Is SystemInfo
TC_MEC_MEC040_SRV_MEF_003_NF
[Documentation]
... Check that the IUT responds with an error
... when it receives a request for returning a systemInfo referred with a wrong systemId
... ETSI GS MEC 040 V3.1.1, clause 7.4.3.1, clause 5.2.2.1.1
... https://www.etsi.org/deliver/etsi_gs/mec/001_099/040/03.01.01_60/gs_mec040v030101p.pdf
[Setup] Test Setup ${NOT_EXISTING_SYSTEM_ID} ${None} ${REMOVE_ACTION}
Retrieve specific system info resource ${NOT_EXISTING_SYSTEM_ID}
Check HTTP Response Status Code Is 404
##TODO double check
TC_MEC_MEC040_SRV_MEF_003_BR
[Documentation]
... Check that the IUT responds with an error
... when it receives a request for returning a systemInfo referred with a wrong systemId
... ETSI GS MEC 040 V3.1.1, clause 7.4.3.1, clause 5.2.2.1.1
... https://www.etsi.org/deliver/etsi_gs/mec/001_099/040/03.01.01_60/gs_mec040v030101p.pdf
Retrieve specific system info resource ${NOT_EXISTING_SYSTEM_ID}
#Check HTTP Response Status Code Is 400
TC_MEC_MEC040_SRV_MEF_004_OK_01
[Documentation]
... Check that the IUT updates the systemInfo when requested by a MEC Orchestrator
... ETSI GS MEC 040 V3.1.1, clause clause 7.4.3.3, clause 5.2.2.1.2
... https://www.etsi.org/deliver/etsi_gs/mec/001_099/040/03.01.01_60/gs_mec040v030101p.pdf
[Setup] Test Setup ${None} SystemInfo ${REGISTER_ACTION}
${SYS_PROVIDER} Get value entry from JSON file SystemInfoUpdate endpoint
Update specific system info resource ${setup_response['body']['systemId']} SystemInfoUpdate
Check HTTP Response Status Code Is 200
Should Be Equal As Strings ${response['body']['systemProvider']} ${SYS_PROVIDER}
[Teardown] Test TearDown ${setup_response['body']['systemId']} ${None} ${REMOVE_ACTION}
TC_MEC_MEC040_SRV_MEF_004_OK_02
[Documentation]
... Check that the IUT updates the systemInfo when requested by a MEC Orchestrator
... ETSI GS MEC 040 V3.1.1, clause clause 7.4.3.3, clause 5.2.2.1.2
... https://www.etsi.org/deliver/etsi_gs/mec/001_099/040/03.01.01_60/gs_mec040v030101p.pdf
[Setup] Test Setup ${None} SystemInfo ${REGISTER_ACTION}
Update specific system info resource ${setup_response['body']['systemId']} SystemInfoUpdate2
${SYS_NAME} Get value entry from JSON file SystemInfoUpdate2 systemName
Check HTTP Response Status Code Is 200
Should Be Equal As Strings ${response['body']['systemName']} ${SYS_NAME}
[Teardown] Test TearDown ${setup_response['body']['systemId']} ${None} ${REMOVE_ACTION}
TC_MEC_MEC040_SRV_MEF_004_OK_03
[Documentation]
... Check that the IUT updates the systemInfo when requested by a MEC Orchestrator
... ETSI GS MEC 040 V3.1.1, clause clause 7.4.3.3, clause 5.2.2.1.2
... https://www.etsi.org/deliver/etsi_gs/mec/001_099/040/03.01.01_60/gs_mec040v030101p.pdf
[Setup] Test Setup ${None} SystemInfo ${REGISTER_ACTION}
Update specific system info resource ${setup_response['body']['systemId']} SystemInfoUpdate3
Check HTTP Response Status Code Is 200
${SYS_NAME} Get value entry from JSON file SystemInfoUpdate3 systemName
${SYS_PROVIDER} Get value entry from JSON file SystemInfoUpdate3 endpoint
Should Be Equal As Strings ${response['body']['systemName']} ${SYS_NAME}
Should Be Equal As Strings ${response['body']['systemProvider']} ${SYS_PROVIDER}
[Teardown] Test TearDown ${setup_response['body']['systemId']} ${None} ${REMOVE_ACTION}
TC_MEC_MEC040_SRV_MEF_004_NF
[Documentation]
... Check that the IUT responds with an error when requested to update an unknown systemInfo
... ETSI GS MEC 040 V3.1.1, clause clause 7.4.3.3, clause 5.2.2.1.2
... https://www.etsi.org/deliver/etsi_gs/mec/001_099/040/03.01.01_60/gs_mec040v030101p.pdf
[Setup] Test Setup ${NOT_EXISTING_SYSTEM_ID} ${None} ${REMOVE_ACTION}
Update specific system info resource ${NOT_EXISTING_SYSTEM_ID} SystemInfoUpdate3
Check HTTP Response Status Code Is 404
##TODO double check the corresponding TP
#TC_MEC_MEC040_SRV_MEF_004_BR_01
#[Documentation]
#... Check that the IUT responds with an error when requested to update with an inconsistant URI
#... ETSI GS MEC 040 V3.1.1, clause clause 7.4.3.3, clause 5.2.2.1.2
#... https://www.etsi.org/deliver/etsi_gs/mec/001_099/040/03.01.01_60/gs_mec040v030101p.pdf
#Update specific system info resource ${NOT_EXISTING_SYSTEM_ID} SystemInfoUpdate3
#Check HTTP Response Status Code Is 400
TC_MEC_MEC040_SRV_MEF_004_BR_02
[Documentation]
... Check that the IUT responds with an error when requested to update with no data provided
... ETSI GS MEC 040 V3.1.1, clause clause 7.4.3.3, clause 5.2.2.1.2
... https://www.etsi.org/deliver/etsi_gs/mec/001_099/040/03.01.01_60/gs_mec040v030101p.pdf
Update specific system info resource ${EXPECTED_SYSTEM_ID} SystemInfoUpdateBR
Check HTTP Response Status Code Is 400
TC_MEC_MEC040_SRV_MEF_005_OK
[Documentation]
... Check that the IUT responds with an error when requested to delete an unknown systemInfo
... ETSI GS MEC 040 V3.1.1, clause clause 7.4.3.5, clause 5.2.2.1.3
... https://www.etsi.org/deliver/etsi_gs/mec/001_099/040/03.01.01_60/gs_mec040v030101p.pdf
[Setup] Test Setup ${None} SystemInfo ${REGISTER_ACTION}
Remove specific system info resource ${EXPECTED_SYSTEM_ID}
Check HTTP Response Status Code Is 204
TC_MEC_MEC040_SRV_MEF_005_NF
[Documentation]
... Check that the IUT responds with an error when requested to delete an unknown systemInfo
... ETSI GS MEC 040 V3.1.1, clause clause 7.4.3.5, clause 5.2.2.1.3
... https://www.etsi.org/deliver/etsi_gs/mec/001_099/040/03.01.01_60/gs_mec040v030101p.pdf
[Setup] Test Setup ${NOT_EXISTING_SYSTEM_ID} ${None} ${REMOVE_ACTION}
Remove specific system info resource ${NOT_EXISTING_SYSTEM_ID}
Check HTTP Response Status Code Is 404
############################################################################
*** Keywords ***
424
425
426
427
428
429
430
431
432
433
434
435
436
437
438
439
440
441
442
443
444
445
446
447
448
449
450
451
452
453
454
455
456
457
458
Test Setup
[Arguments] ${systemId} ${content} ${action}
Set Headers {"Accept":"application/json"}
Set Headers {"Content-Type":"application/json"}
Set Headers {"Authorization":"${TOKEN}"}
IF '''${action}''' == '''${REGISTER_ACTION}'''
${file}= Catenate SEPARATOR= jsons/ ${content} .json
${body}= Get File ${file}
POST ${apiRoot}/${apiName}/${apiVersion}/fed_resources/system_info ${body}
${output}= Output response
Set Suite Variable ${setup_response} ${output}
END
IF '''${action}''' == '''${REMOVE_ACTION}'''
DELETE ${apiRoot}/${apiName}/${apiVersion}/fed_resources/system_info/${systemId}
END
Test Teardown
[Arguments] ${systemId} ${content} ${action}
Set Headers {"Accept":"application/json"}
Set Headers {"Content-Type":"application/json"}
Set Headers {"Authorization":"${TOKEN}"}
IF '''${action}''' == '''${REGISTER_ACTION}'''
${file}= Catenate SEPARATOR= jsons/ ${content} .json
${body}= Get File ${file}
POST ${apiRoot}/${apiName}/${apiVersion}/fed_resources/system_info ${body}
END
IF '''${action}''' == '''${REMOVE_ACTION}'''
DELETE ${apiRoot}/${apiName}/${apiVersion}/fed_resources/system_info/${systemId}
END
Retrieve all system info resources
Should Be True ${PIC_MEC_PLAT} == 1
Should Be True ${PIC_SERVICES} == 1
Set Headers {"Accept":"application/json"}
Set Headers {"Content-Type":"*/*"}
Set Headers {"Authorization":"${TOKEN}"}
GET ${apiRoot}/${apiName}/${apiVersion}/fed_resources/system_info
${output}= Output response
Set Suite Variable ${response} ${output}
Retrieve all system info resources with query params
[Arguments] ${query_params}
Should Be True ${PIC_MEC_PLAT} == 1
Should Be True ${PIC_SERVICES} == 1
Set Headers {"Accept":"application/json"}
Set Headers {"Content-Type":"*/*"}
Set Headers {"Authorization":"${TOKEN}"}
GET ${apiRoot}/${apiName}/${apiVersion}/fed_resources/system_info?${query_params}
${output}= Output response
478
479
480
481
482
483
484
485
486
487
488
489
490
491
492
493
494
495
496
497
498
499
500
501
502
503
504
505
506
507
508
509
510
511
512
513
514
515
516
517
518
519
520
521
522
523
524
525
526
527
528
529
530
531
532
533
534
535
536
537
538
Set Suite Variable ${response} ${output}
Retrieve specific system info resource
[Arguments] ${SYSTEM_INFO_ID}
Should Be True ${PIC_MEC_PLAT} == 1
Should Be True ${PIC_SERVICES} == 1
Set Headers {"Accept":"application/json"}
Set Headers {"Content-Type":"*/*"}
Set Headers {"Authorization":"${TOKEN}"}
GET ${apiRoot}/${apiName}/${apiVersion}/fed_resources/system_info/${SYSTEM_INFO_ID}
${output}= Output response
Set Suite Variable ${response} ${output}
Register System Info
[Arguments] ${content}
Should Be True ${PIC_MEC_PLAT} == 1
Should Be True ${PIC_SERVICES} == 1
Set Headers {"Accept":"application/json"}
Set Headers {"Content-Type":"application/json"}
Set Headers {"Authorization":"${TOKEN}"}
${file}= Catenate SEPARATOR= jsons/ ${content} .json
${body}= Get File ${file}
POST ${apiRoot}/${apiName}/${apiVersion}/fed_resources/system_info ${body}
${output}= Output response
Set Suite Variable ${response} ${output}
Update specific system info resource
[Arguments] ${systemId} ${content}
Should Be True ${PIC_MEC_PLAT} == 1
Should Be True ${PIC_SERVICES} == 1
Set Headers {"Accept":"application/json"}
Set Headers {"Content-Type":"application/json"}
Set Headers {"Authorization":"${TOKEN}"}
${file}= Catenate SEPARATOR= jsons/ ${content} .json
${body}= Get File ${file}
PATCH ${apiRoot}/${apiName}/${apiVersion}/fed_resources/system_info/${systemId} ${body}
${output}= Output response
Set Suite Variable ${response} ${output}
Remove specific system info resource
[Arguments] ${systemId}
Should Be True ${PIC_MEC_PLAT} == 1
Should Be True ${PIC_SERVICES} == 1
Set Headers {"Accept":"application/json"}
Set Headers {"Content-Type":"application/json"}
DELETE ${apiRoot}/${apiName}/${apiVersion}/fed_resources/system_info/${systemId}
${output}= Output response
Set Suite Variable ${response} ${output}
Retrieve all system info resources wrong URL
Should Be True ${PIC_MEC_PLAT} == 1
Should Be True ${PIC_SERVICES} == 1
Set Headers {"Accept":"application/json"}
Set Headers {"Content-Type":"*/*"}
Set Headers {"Authorization":"${TOKEN}"}
GET ${apiRoot}/${apiName}/v10/fed_resources/system_info
${output}= Output response
Set Suite Variable ${response} ${output}