Original line number Diff line number Diff line
Y''[Documentation]   robot --outputdir ../../../outputs ./FederationEnablement.robot
...    Test Suite to validate the Federation Enablement API (FED) operations.

*** Settings ***
Resource    environment/variables.txt
Resource    ../../pics.txt
Resource    ../../GenericKeywords.robot
Library     REST    ${SCHEMA}://${HOST}:${PORT}    ssl_verify=false
Library     OperatingSystem    

*** Test Cases ***
TP_MEC_MEC040_SRV_MEF_001_OK
    [Documentation]
    ...  Check that the IUT responds with a list of all available systemInfo 
    ...  when requested by a MEC Orchestrator - No query parameters
    ...  ETSI GS MEC 040 V3.1.1, clause 7.3.3.1, clause 5.2.2.2
    ...  https://www.etsi.org/deliver/etsi_gs/mec/001_099/040/03.01.01_60/gs_mec040v030101p.pdf
    Retrieve all system info resources
    Check HTTP Response Status Code Is    200
    Check HTTP Response Body Json Schema Is  SystemInfoList


TP_MEC_MEC040_SRV_MEF_001_OK_02
    [Documentation]
    ...  Check that the IUT responds with a selection of all available systemInfo
    ...  when requested by a MEC Orchestrator - SystemId query parameters
    ...  ETSI GS MEC 040 V3.1.1, clause 7.3.3.1, clause 5.2.2.2
    ...  https://www.etsi.org/deliver/etsi_gs/mec/001_099/040/03.01.01_60/gs_mec040v030101p.pdf
    Retrieve all system info resources with query params   ${SYSTEM_ID_QUERY_PARAM}
    Check HTTP Response Status Code Is    200
    Check HTTP Response Body Json Schema Is  SystemInfoList
    FOR  ${element}  IN  @{response['body']}
      Should Be Equal As Strings    ${element}[systemId]      ${EXPECTED_SYSTEM_ID}
    END

TP_MEC_MEC040_SRV_MEF_001_OK_03
    [Documentation]
    ...  Check that the IUT responds with a selection of all available systemInfo 
    ...  when requested by a MEC Orchestrator - Multiple SystemId query parameters
    ...  ETSI GS MEC 040 V3.1.1, clause 7.3.3.1, clause 5.2.2.2
    ...  https://www.etsi.org/deliver/etsi_gs/mec/001_099/040/03.01.01_60/gs_mec040v030101p.pdf
    Retrieve all system info resources with query params   ${MULTIPLE_SYSTEM_ID_QUERY_PARAM}
    Check HTTP Response Status Code Is    200
    Check HTTP Response Body Json Schema Is  SystemInfoList
    
    FOR  ${element}  IN  @{response['body']}
      IF    '''${element}[systemId]''' == '''${EXPECTED_SYSTEM_ID}'''
        ${item}    Set Variable   ${TRUE}
      END
      IF    '''${element}[systemId]''' == '''${EXPECTED_SYSTEM_ID2}'''
        ${item2}    Set Variable   ${TRUE}
      END
    END
    Should Be True  ${item}
    Should Be True  ${item2}
   
TP_MEC_MEC040_SRV_MEF_001_OK_04
    [Documentation]
    ...  Check that the IUT responds with a selection of all available systemInfo
    ...  when requested by a MEC Orchestrator - Empty SystemId query parameters
    ...  ETSI GS MEC 040 V3.1.1, clause 7.3.3.1, clause 5.2.2.2
    ...  https://www.etsi.org/deliver/etsi_gs/mec/001_099/040/03.01.01_60/gs_mec040v030101p.pdf
    Retrieve all system info resources
    Check HTTP Response Status Code Is    200
    Check HTTP Response Body Json Schema Is  SystemInfoList

TP_MEC_MEC040_SRV_MEF_001_OK_05
    [Documentation]
    ...  Check that the IUT responds with a selection of all available systemInfo
    ...  when requested by a MEC Orchestrator - SystemName query parameters
    ...  ETSI GS MEC 040 V3.1.1, clause 7.3.3.1, clause 5.2.2.2
    ...  https://www.etsi.org/deliver/etsi_gs/mec/001_099/040/03.01.01_60/gs_mec040v030101p.pdf
    Retrieve all system info resources with query params   ${SYSTEM_NAME_QUERY_PARAM}
    Check HTTP Response Status Code Is    200
    Check HTTP Response Body Json Schema Is  SystemInfoList
    FOR  ${element}  IN  @{response['body']}
      Should Be Equal As Strings    ${element}[systemName]      ${EXPECTED_SYSTEM_NAME}
    END

TP_MEC_MEC040_SRV_MEF_001_OK_06
    [Documentation]
    ...  Check that the IUT responds with a selection of all available systemInfo
    ...  when requested by a MEC Orchestrator - Multiple SystemName query parameters
    ...  ETSI GS MEC 040 V3.1.1, clause 7.3.3.1, clause 5.2.2.2
    ...  https://www.etsi.org/deliver/etsi_gs/mec/001_099/040/03.01.01_60/gs_mec040v030101p.pdf
    Retrieve all system info resources with query params     ${MUTIPLE_SYSTEM_NAME_QUERY_PARAM}
    Check HTTP Response Status Code Is    200
    Check HTTP Response Body Json Schema Is  SystemInfoList
    FOR  ${element}  IN  @{response['body']}
      IF    '''${element}[systemName]''' == '''${EXPECTED_SYSTEM_NAME}'''
        ${item}    Set Variable   ${TRUE}
      END
      IF    '''${element}[systemName]''' == '''${EXPECTED_SYSTEM_NAME2}'''
        ${item2}    Set Variable   ${TRUE}
      END
    END
    Should Be True  ${item}
    Should Be True  ${item2}


TP_MEC_MEC040_SRV_MEF_001_OK_07
    [Documentation]
    ...  Check that the IUT responds with a selection of all available systemInfo
    ...  when requested by a MEC Orchestrator - Empty SystemName query parameters
    ...  ETSI GS MEC 040 V3.1.1, clause 7.3.3.1, clause 5.2.2.2
    ...  https://www.etsi.org/deliver/etsi_gs/mec/001_099/040/03.01.01_60/gs_mec040v030101p.pdf
    Retrieve all system info resources with query params     ${EMPTY_SYSTEM_NAME_QUERY_PARAM}
    Check HTTP Response Status Code Is    200
    Check HTTP Response Body Json Schema Is  SystemInfoList
    FOR  ${element}  IN  @{response['body']}
      Should Be Equal As Strings    ${element}[systemName]      ${EMPTY}
    END

TP_MEC_MEC040_SRV_MEF_001_OK_08
    [Documentation]
    ...  Check that the IUT responds with a selection of all available systemInfo
    ...  when requested by a MEC Orchestrator - systemProvider query parameters
    ...  ETSI GS MEC 040 V3.1.1, clause 7.3.3.1, clause 5.2.2.2
    ...  https://www.etsi.org/deliver/etsi_gs/mec/001_099/040/03.01.01_60/gs_mec040v030101p.pdf
    Retrieve all system info resources with query params     ${SYSTEM_PROVIDER_QUERY_PARAM}
    Check HTTP Response Status Code Is    200
    Check HTTP Response Body Json Schema Is  SystemInfoList
    FOR  ${element}  IN  @{response['body']}
      Should Be Equal As Strings    ${element}[systemProvider]      ${EXPECTED_SYSTEM_PROVIDER}
    END    

TP_MEC_MEC040_SRV_MEF_001_OK_09
    [Documentation]
    ...  Check that the IUT responds with a selection of all available systemInfo
    ...  when requested by a MEC Orchestrator - Multiple systemProvider query parameters
    ...  ETSI GS MEC 040 V3.1.1, clause 7.3.3.1, clause 5.2.2.2
    ...  https://www.etsi.org/deliver/etsi_gs/mec/001_099/040/03.01.01_60/gs_mec040v030101p.pdf
    Retrieve all system info resources with query params   ${MUTIPLE_SYS_PROVIDER_QUERY_PAR}
    Check HTTP Response Status Code Is    200
    Check HTTP Response Body Json Schema Is  SystemInfoList
    FOR  ${element}  IN  @{response['body']}
      IF    '''${element}[systemProvider]''' == '''${EXPECTED_SYSTEM_PROVIDER}'''
        ${item}    Set Variable   ${TRUE}
      END
      IF    '''${element}[systemProvider]''' == '''${EXPECTED_SYSTEM_PROVIDER2}'''
        ${item2}    Set Variable   ${TRUE}
      END
    END
    Should Be True  ${item}
    Should Be True  ${item2} 


TP_MEC_MEC040_SRV_MEF_001_OK_10
    [Documentation]
    ...  Check that the IUT responds with a selection of all available systemInfo
    ...  when requested by a MEC Orchestrator - Empty systemProvider query parameters
    ...  ETSI GS MEC 040 V3.1.1, clause 7.3.3.1, clause 5.2.2.2
    ...  https://www.etsi.org/deliver/etsi_gs/mec/001_099/040/03.01.01_60/gs_mec040v030101p.pdf
    Retrieve all system info resources with query params   ${EMPTY_SYSTEM_PROVIDER_QUERY_PARAM}
    Check HTTP Response Status Code Is    200
    Check HTTP Response Body Json Schema Is  SystemInfoList
    FOR  ${element}  IN  @{response['body']}
      Should Be Equal As Strings    ${element}[systemProvider]      ${EMPTY}
    END
    
TP_MEC_MEC040_SRV_MEF_001_OK_11
    [Documentation]
    ...  Check that the IUT responds with a selection of all available systemInfo
    ...  when requested by a MEC Orchestrator - Multiple query parameters
    ...  ETSI GS MEC 040 V3.1.1, clause 7.3.3.1, clause 5.2.2.2
    ...  https://www.etsi.org/deliver/etsi_gs/mec/001_099/040/03.01.01_60/gs_mec040v030101p.pdf
    Retrieve all system info resources with query params   ${FILTER_ON_SYSTEM_ID_AND_NAME}
    Check HTTP Response Status Code Is    200
    Check HTTP Response Body Json Schema Is  SystemInfoList
    ${counterSystemId}    Set Variable    ${0}
    ${counterSystemName}  Set Variable    ${0}
    FOR  ${element}  IN  @{response['body']}
      IF    '''${element}[systemId]''' == '''${EXPECTED_SYSTEM_ID}'''
        ${counterSystemId}=  set variable  ${counterSystemId+1}
      END
      IF    '''${element}[systemId]''' == '''${EXPECTED_SYSTEM_ID}'''
         ${counterSystemName}=  set variable  ${counterSystemName+1}
      END
      ${counterSystemName}=  set variable  ${counterSystemName+1}
    END
    Should Be True    '${counterSystemName}'>'0'
    Should Be True    '${counterSystemId}'>'0'
                                    
############################################################################
      
*** Keywords ***
Retrieve all system info resources
    Should Be True    ${PIC_MEC_PLAT} == 1
    Should Be True    ${PIC_SERVICES} == 1
    Set Headers    {"Accept":"application/json"}
    Set Headers    {"Content-Type":"*/*"}
    Set Headers    {"Authorization":"${TOKEN}"}
    GET   ${apiRoot}/${apiName}/${apiVersion}/fed_resources/system_info
    ${output}=    Output    response
    Set Suite Variable    ${response}    ${output}
    

Retrieve all system info resources with query params
    [Arguments]     ${query_params}
    Should Be True    ${PIC_MEC_PLAT} == 1
    Should Be True    ${PIC_SERVICES} == 1
    Set Headers    {"Accept":"application/json"}
    Set Headers    {"Content-Type":"*/*"}
    Set Headers    {"Authorization":"${TOKEN}"}
    GET   ${apiRoot}/${apiName}/${apiVersion}/fed_resources/system_info?${query_params}
    ${output}=    Output    response
    Set Suite Variable    ${response}    ${output}
 No newline at end of file
+33 −0
Original line number Diff line number Diff line
*** Variables ***
# Generic variables
${SCHEMA}                               http
${HOST}                                 127.0.0.1
${PORT}                                 8084
${response}                             {}
${TOKEN}                                YWxhZGRpbjpvcGVuc2VzYW1l
${apiRoot}        
${apiName}                              fed-enablement
${apiVersion}                           v1

${EXPECTED_SYSTEM_ID}                   SYSTEM_ID
${EXPECTED_SYSTEM_ID2}                  SYSTEM_ID2
${SYSTEM_ID_QUERY_PARAM}                systemId=${EXPECTED_SYSTEM_ID} 
${MULTIPLE_SYSTEM_ID_QUERY_PARAM}       systemId=${EXPECTED_SYSTEM_ID},${EXPECTED_SYSTEM_ID2}
${EMPTY_SYSTEM_ID_QUERY_PARAM}          systemId=

${EXPECTED_SYSTEM_NAME}                 SYSTEM_NAME
${EXPECTED_SYSTEM_NAME2}                SYSTEM_NAME2
${SYSTEM_NAME_QUERY_PARAM}              systemName=${EXPECTED_SYSTEM_NAME}
${MUTIPLE_SYSTEM_NAME_QUERY_PARAM}      systemName=${EXPECTED_SYSTEM_NAME},${EXPECTED_SYSTEM_NAME2}    
${EMPTY_SYSTEM_NAME_QUERY_PARAM}        systemName=

${EXPECTED_SYSTEM_PROVIDER}             SYSTEM_PROVIDER
${EXPECTED_SYSTEM_PROVIDER2}            SYSTEM_PROVIDER2
${SYSTEM_PROVIDER_QUERY_PARAM}          systemProvider=${EXPECTED_SYSTEM_PROVIDER}
${MUTIPLE_SYS_PROVIDER_QUERY_PAR}       systemProvider=${EXPECTED_SYSTEM_PROVIDER},${EXPECTED_SYSTEM_PROVIDER2}    
${EMPTY_SYSTEM_PROVIDER_QUERY_PARAM}        systemProvider=


${FILTER_ON_SYSTEM_ID_AND_NAME}       systemId=${EXPECTED_SYSTEM_ID},systemName=${EXPECTED_SYSTEM_NAME}

+5 −0
Original line number Diff line number Diff line
{
  "systemId": "systemId",
  "systemName": "systemNamea",
  "systemProvider": "systemProvider"
}
 No newline at end of file
+24 −0
Original line number Diff line number Diff line
{
  "title": "SystemInfo",
  "type": "object",
  "description": "This type represents an information provided by the MEC orchestrator as a part of the \"Registration of MEC system to the federation\"",
  "properties": {
    "systemId": {
      "description": "Identifier of the MEC system. For the uniqueness of the identifier across the federated MEC systems, UUID format [i.9] is recommended. Shall be absent in POST request, and present otherwise.",
      "type": "string"
    },
    "systemName": {
      "description": "The name of the MEC system. This is how the MEC system identifies other MEC systems",
      "type": "string"
    },
    "systemProvider": {
      "description": "Provider of the MEC system.",
      "type": "string"
    }
  },
  "required": [
    "systemId",
    "systemName",
    "systemProvider"
  ]
}
 No newline at end of file
+27 −0
Original line number Diff line number Diff line
{
  "type": "array",
  "items": {
    "title": "SystemInfo",
    "type": "object",
    "description": "This type represents an information provided by the MEC orchestrator as a part of the \"Registration of MEC system to the federation\"",
    "properties": {
      "systemId": {
        "description": "Identifier of the MEC system. For the uniqueness of the identifier across the federated MEC systems, UUID format [i.9] is recommended. Shall be absent in POST request, and present otherwise.",
        "type": "string"
      },
      "systemName": {
        "description": "The name of the MEC system. This is how the MEC system identifies other MEC systems",
        "type": "string"
      },
      "systemProvider": {
        "description": "Provider of the MEC system.",
        "type": "string"
      }
    },
    "required": [
      "systemId",
      "systemName",
      "systemProvider"
    ]
  }
}
 No newline at end of file