*** Settings ***
Resource environment/variables.txt
Library REST ${VNFM_SCHEMA}://${VNFM_HOST}:${VNFM_PORT}
Library OperatingSystem
Library JSONLibrary
Library JSONSchemaLibrary schemas/
*** Test Cases ***
POST Change external VNF connectivity
[Documentation] Test ID: 6.3.5.10.1
... Test title: POST Change external VNF connectivity
... Test objective: The objective is to test that POST method trigger a change in VNF external connectivity
... Pre-conditions: none
... Reference: section 5.4.11.3.1 - SOL002 v2.4.1
... Config ID: Config_prod_VE
... Applicability: none
... Post-Conditions: in response header Location should not be null
POST Change External VNF Connectivity
Check HTTP Response Status Code Is 202
Check Operation Occurrence Id
GET Change external VNF connectivity - Method not implemented
[Documentation] Test ID: 6.3.5.10.2
... Test title: GET Change external VNF connectivity - Method not implemented
... Test objective: The objective is to test that GET method is not implemented
... Pre-conditions: none
... Reference: section 5.4.11.3.2 - SOL002 v2.4.1
... Config ID: Config_prod_VE
... Applicability: none
... Post-Conditions: none
GET Change External VNF Connectivity
Check HTTP Response Status Code Is 405
PUT Change external VNF connectivity - Method not implemented
[Documentation] Test ID: 6.3.5.10.3
... Test title: PUT Change external VNF connectivity - Method not implemented
... Test objective: The objective is to test that PUT method is not implemented
... Pre-conditions: none
... Reference: section 5.4.11.3.3 - SOL002 v2.4.1
... Config ID: Config_prod_VE
... Applicability: none
... Post-Conditions: none
PUT Change External VNF Connectivity
Check HTTP Response Status Code Is 405
PATCH Change external VNF connectivity - Method not implemented
[Documentation] Test ID: 6.3.5.10.4
... Test title: PATCH Change external VNF connectivity - Method not implemented
... Test objective: The objective is to test that PATCH method is not implemented
... Pre-conditions: none
... Reference: section 5.4.11.3.4 - SOL002 v2.4.1
... Config ID: Config_prod_VE
... Applicability: none
... Post-Conditions: none
PATCH Change External VNF Connectivity
Check HTTP Response Status Code Is 405
DELETE Change external VNF connectivity - Method not implemented
[Documentation] Test ID: 6.3.5.10.5
... Test title: DELETE Change external VNF connectivity - Method not implemented
... Test objective: The objective is to test that DELETE method is not implemented
... Pre-conditions: none
... Reference: section 5.4.11.3.5 - SOL002 v2.4.1
... Config ID: Config_prod_VE
... Applicability: none
... Post-Conditions: none
DELETE Change External VNF Connectivity
Check HTTP Response Status Code Is 405
Check resource existance
Set Headers {"Accept":"${ACCEPT}"}
Set Headers {"Content-Type": "${CONTENT_TYPE}"}
Run Keyword If ${AUTH_USAGE} == 1 Set Headers {"Authorization":"${AUTHORIZATION}"}
Get ${apiRoot}/${apiName}/${apiVersion}/vnf_instances/${vnfInstanceId}
Integer response status 200
Launch another LCM operation
Set Headers {"Accept":"${ACCEPT}"}
Set Headers {"Content-Type": "${CONTENT_TYPE}"}
Run Keyword If ${AUTH_USAGE} == 1 Set Headers {"Authorization":"${AUTHORIZATION}"}
Post ${apiRoot}/${apiName}/${apiVersion}/vnf_instances/${vnfInstanceId}/scale ${body}
Integer response status 202