Newer
Older
*** Settings ***
# Suite setup Expect spec SOL003-VNFLifecycleManagement-API.yaml
Resource environment/variables.txt
Resource FaultManagement-APIKeyword.robot
Library REST ${VNFM_SCHEMA}://${VNFM_HOST}:${VNFM_PORT} ssl_verify=false
Library JSONLibrary
Library JSONSchemaLibrary schemas/
Library OperatingSystem
POST Alarms - Method not implemented
[Documentation] Test ID: 7.3.5.1.1
... Test title: POST Alarms - Method not implemented
... Test objective: The objective is to test that Post method is not allowed to create Fault management alarms on VNF
... Pre-conditions: none
... Reference: Clause 7.4.2.3.1 - ETSI GS NFV-SOL 003 [1] v2.6.1
... Config ID: Config_prod_VNFM
... Applicability: none
... Post-Conditions: none
Send POST request for fault management Alarms
Check HTTP Response Status Code Is 405
Get information about multiple alarms
[Documentation] Test ID: 7.3.5.1.2
... Test objective: The objective is to retrieve information about the alarm list and perform a JSON schema and content validation of the returned alarms data structure
... Pre-conditions: none
... Reference: Clause 7.4.2.3.2 - ETSI GS NFV-SOL 003 [1] v2.6.1
... Applicability: none
... Post-Conditions: none
GET Fault Management Alarms
Check HTTP Response Status Code Is 200
Check HTTP Response Body Json Schema Is Alarms
... Test title: Get information about multiple alarms with filter
... Test objective: The objective is to retrieve information about the alarm list and perform a JSON schema and content validation of the returned alarms data structure, and verify that the retrieved information matches the issued attribute-based filters
... Pre-conditions: none
... Reference: Clause 7.4.2.3.2 - ETSI GS NFV-SOL 003 [1] v2.6.1
... Applicability: none
... Post-Conditions: none
GET Fault Management Alarms With Filters
Check HTTP Response Status Code Is 200
Check HTTP Response Body Json Schema Is Alarms
Get information about multiple alarms Bad Request Invalid attribute-based filtering parameters
... Test title: Get information about multiple alarms Bad Request Invalid attribute-based filtering parameters
... Test objective: The objective is to try to retrieve information about the alarm list with invalid filters and perform a JSON schema and content validation of the returned problem details data structure
... Reference: Clause 7.4.2.3.2 - ETSI GS NFV-SOL 003 [1] v2.6.1
... Applicability: none
... Post-Conditions: none
GET Fault Management Alarms With Invalid Filters
Check HTTP Response Status Code Is 400
Check HTTP Response Body Json Schema Is ProblemDetails
GET information about multiple alarms with "all_fields" attribute selector
[Documentation] Test ID: 7.3.5.1.5
... Test title: GET information about multiple alarms with "all_fields" attribute selector
... Test objective: The objective is to retrieve information about the alarm list
... Pre-conditions:
... Reference: Clause 7.4.2.3.2 - ETSI GS NFV-SOL 003 [1] v2.6.1
... Config ID: Config_prod_VNFM
... Applicability:
... Post-Conditions:
GET Alarms Task with all_fields attribute selector
Check HTTP Response Status Code Is 200
GET information about multiple alarms with exclude_default attribute selector
[Documentation] Test ID: 7.3.5.1.6
... Test title: GET information about multiple alarms with "exclude_default" attribute selector
... Test objective: The objective is to retrieve information about the alarm list
... Pre-conditions:
... Reference: Clause 7.4.2.3.2 - ETSI GS NFV-SOL 003 [1] v2.6.1
... Config ID: Config_prod_VNFM
... Applicability:
... Post-Conditions:
GET Alarms Task with exclude_default attribute selector
Check HTTP Response Status Code Is 200
GET information about multiple alarms with fields attribute selector
[Documentation] Test ID: 7.3.5.1.7
... Test title: GET information about multiple alarms with fields attribute selector
... Test objective: The objective is to retrieve information about the alarm list
... Pre-conditions:
... Reference: Clause 7.4.2.3.2 - ETSI GS NFV-SOL 003 [1] v2.6.1
... Config ID: Config_prod_VNFM
... Applicability:
... Post-Conditions:
GET Alarms Task with fields attribute selector
Check HTTP Response Status Code Is 200
GET information about multiple alarms with "exclude_fields" attribute selector
[Documentation] Test ID: 7.3.5.1.8
... Test title: GET information about multiple alarms with "exclude_fields" attribute selector
... Test objective: The objective is to retrieve information about the alarm list
... Pre-conditions:
... Reference: Clause 7.4.2.3.2 - ETSI GS NFV-SOL 003 [1] v2.6.1
... Config ID: Config_prod_VNFM
... Applicability:
... Post-Conditions: none
GET Alarms Task with exclude_fields attribute selector
Check HTTP Response Status Code Is 200
PUT Alarms - Method not implemented
... Test title: PUT Alarms - Method not implemented
... Test objective: The objective is to test that PUT method is not allowed to for Fault management alarms on VNF
... Pre-conditions: none
... Reference: Clause 7.4.2.3.3 - ETSI GS NFV-SOL 003 [1] v2.6.1
... Config ID: Config_prod_VNFM
... Applicability: none
... Post-Conditions: none
PUT Fault management Alarms
Check HTTP Response Status Code Is 405
PATCH Alarms - Method not implemented
[Documentation] Test ID: 7.3.5.1.10
... Test title: PATCH Alarms - Method not implemented
... Test objective: The objective is to test that PATCH method is not allowed to for Fault management alarms on VNF
... Pre-conditions: none
... Reference: Clause 7.4.2.3.4 - ETSI GS NFV-SOL 003 [1] v2.6.1
... Config ID: Config_prod_VNFM
... Applicability: none
... Post-Conditions: none
PATCH Fault management Alarms
Check HTTP Response Status Code Is 405
DELETE Alarms - Method not implemented
[Documentation] Test ID: 7.3.5.1.11
... Test title: POST Alarms - Method not implemented
... Test objective: The objective is to test that DELETE method is not allowed for Fault management alarms on VNF
... Pre-conditions: none
... Reference: Clause 7.4.2.3.5 - ETSI GS NFV-SOL 003 [1] v2.6.1
... Config ID: Config_prod_VNFM
... Applicability: none
... Post-Conditions: none
DELETE Fault management Alarms
Check HTTP Response Status Code Is 405
Check Postcondition VNF fault management alarms Exists
Get information about multiple alarms as a Paged Response
[Documentation] Test ID: 7.3.5.1.12
... Test title: Get information about multiple alarms as a Paged Response
... Test objective: The objective is to retrieve information about the alarm list as a Paged Response
... Pre-conditions: none
... Reference: Clause 7.4.2.3.2 - ETSI GS NFV-SOL 003 [1] v2.6.1
... Config ID: Config_prod_VNFM
... Applicability: none
... Post-Conditions: none
GET Fault Management Alarms
Check HTTP Response Status Code Is 200
Check LINK in Header
Get information about multiple alarms - Bad Request Response too Big
[Documentation] Test ID: 7.3.5.1.13
... Test title: Get information about multiple alarms - Bad Request Response too Big
... Test objective: The objective is to try to retrieve information about the alarm list because response is too big and perform a JSON schema and content validation of the returned problem details data structure
... Pre-conditions: none
... Reference: Clause 7.4.2.3.2 - ETSI GS NFV-SOL 003 [1] v2.6.1
... Config ID: Config_prod_VNFM
... Applicability: none
... Post-Conditions: none
GET Fault Management Alarms
Check HTTP Response Status Code Is 400
Check HTTP Response Body Json Schema Is ProblemDetails