*** Settings ***
Resource environment/variables.txt
Resource VnfLcmOperationKeywords.robot
*** Test Cases ***
POST Individual VNF Snapshot - Method not implemented
[Documentation] Test ID: 6.3.5.26.1
... Test title: POST Individual VNF Snapshot - Method not implemented
... Test objective: The objective is to test that POST method is not implemented
... Pre-conditions: none
... Reference: Clause 5.4.24.3.1 - ETSI GS NFV-SOL 002 [2] v3.6.1
... Config ID: Config_prod_VE
... Applicability: none
... Post-Conditions: none
POST individual VNF Snapshot
Check HTTP Response Status Code Is 405
GET Information about an individual VNF Snapshot - SUCCESSFUL
[Documentation] Test ID: 6.3.5.26.2
... Test title: GET Information about an individual VNF Snapshot - SUCCESSFUL
... Test objective: The objective is to GET information about an individual VNF Snapshot
... Reference: Clause 5.4.24.3.2 - ETSI GS NFV-SOL 002 [2] v3.6.1
... Config ID: Config_prod_VE
... Applicability: none
... Post-Conditions: none
GET individual VNF Snapshot
Check HTTP Response Status Code Is 200
Check HTTP Response Body Json Schema Is VnfSnapshotInfo
GET Information about an individual VNF Snapshot - NOT FOUND
[Documentation] Test ID: 6.3.5.26.3
... Test title: GET Information about an individual VNF Snapshot - NOT FOUND
... Test objective: The objective is to test that the retrieval of individual VNF Snapshot fails when using an invalid resource identifier.
... Pre-conditions: At least one individual VNF Snapshot is available in the NFV-MANO.
... Reference: Clause 5.4.24.3.2 - ETSI GS NFV-SOL 002 [2] v3.6.1
... Config ID: Config_prod_NFV-MANO
... Applicability: none
... Post-Conditions: none
GET Individual VNF Snapshot with Invalid URI
Check HTTP Response Status Code Is 404
Check HTTP Response Body Json Schema Is ProblemDetails
PUT Individual VNF Snapshot - Method not implemented
[Documentation] Test ID: 6.3.5.26.4
... Test title: PUT Individual VNF Snapshot - Method not implemented
... Test objective: The objective is to test that PUT method is not implemented
... Pre-conditions: none
... Reference: Clause 5.4.24.3.3 - ETSI GS NFV-SOL 002 [2] v3.6.1
... Config ID: Config_prod_VE
... Applicability: none
... Post-Conditions: VNF Snapshot not modified
PUT individual VNF Snapshot
Check HTTP Response Status Code Is 405
PATCH Individual VNF Snapshot - Method not implemented
[Documentation] Test ID: 6.3.5.26.5
... Test title: PATCH Individual VNF Snapshot - Method not implemented
... Test objective: The objective is to test that PATCH method is not implemented
... Reference: Clause 5.4.24.3.4 - ETSI GS NFV-SOL 002 [2] v3.6.1
... Config ID: Config_prod_VE
... Applicability: none
PATCH individual VNF Snapshot
Check HTTP Response Status Code Is 405
DELETE Individual VNF Snapshot
[Documentation] Test ID: 6.3.5.26.6
... Test title: DELETE Individual VNF Snapshot
... Test objective: The objective is to delete a VNF Snapshot
... Pre-conditions: none
... Reference: Clause 5.4.24.3.5 - ETSI GS NFV-SOL 002 [2] v3.6.1
... Config ID: Config_prod_VE
... Applicability: none
... Post-Conditions: VNF Snapshot deleted
DELETE individual VNF Snapshot
Check HTTP Response Status Code Is 204
DELETE Individual VNF Snapshot - Conflict
[Documentation] Test ID: 6.3.5.26.7
... Test title: DELETE Individual VNF Snapshot Conflict
... Test objective: The objective is to verify that The operation cannot be executed currently, due to a conflict with the state of the VNF Snapshot resource.
... Pre-conditions: none
... Reference: Clause 5.4.24.3.5 - ETSI GS NFV-SOL 002 [2] v3.6.1
... Config ID: Config_prod_VE
... Applicability: VNF snapshot is in use by some operation such as reverting a VNF instance to a VNF snapshot or creating a VNF snapshot package.
... Post-Conditions: none
DELETE individual VNF Snapshot - CONFLICT
Check HTTP Response Status Code Is 409
Check HTTP Response Body Json Schema Is ProblemDetails