IndividualAlarm.robot 5.82 KB
Newer Older
*** Settings ***
Sana Zulfiqar's avatar
Sana Zulfiqar committed

Resource    environment/variables.txt 
Resource    FaultManagement-APIKeyword.robot
Library    REST    ${VNFM_SCHEMA}://${VNFM_HOST}:${VNFM_PORT}     ssl_verify=false
Library    OperatingSystem
Library    JSONLibrary
Library    JSONSchemaLibrary    schemas/
Library    DependencyLibrary

*** Test Cases ***
POST Alarm - Method not implemented
     [Documentation]    Test ID: 7.3.5.2.1
    ...    Test title: POST Alarm - Method not implemented
    ...    Test objective: The objective is to test that Post method is not allowed to create Fault management individual alarm on VNF 
    ...    Pre-conditions: none
    ...    Reference: Clause 7.4.3.3.1 - ETSI GS NFV-SOL 003 [1] v2.8.1
    ...    Config ID: Config_prod_VNFM
    ...    Applicability: none
    ...    Post-Conditions: none  
    Send POST request for fault management Individual Alarm
    Check HTTP Response Status Code Is    405   
Get information about an fault management individual alarm
    [Documentation]    Test ID: 7.3.5.2.2
    ...    Test title: Get information about an fault management individual alarm
    ...    Test objective: The objective is to retrieve information about an individual alarm and perform a JSON schema and content validation of the returned alarm data structure
mengxuan.zhao's avatar
mengxuan.zhao committed
    ...    Pre-conditions: The related alarm exists
    ...    Reference: Clause 7.4.3.3.2 - ETSI GS NFV-SOL 003 [1] v2.8.1
mengxuan.zhao's avatar
mengxuan.zhao committed
    ...    Config ID: Config_prod_VNFM
    ...    Applicability: none
    ...    Post-Conditions:  none 
    GET Fault Management Individual Alarm
    Check HTTP Response Status Code Is    200
    Check HTTP Response Body Json Schema Is    alarm

PUT Alarm - Method not implemented
    [Documentation]    Test ID: 7.3.5.2.3
    ...    Test title: PUT Alarm - Method not implemented
Sana Zulfiqar's avatar
Sana Zulfiqar committed
    ...    Test objective: The objective is to test that PUT method is not allowed to for Fault management individual alarm on VNF 
    ...    Pre-conditions: none
    ...    Reference: Clause 7.4.3.3.3 - ETSI GS NFV-SOL 003 [1] v2.8.1
    ...    Config ID: Config_prod_VNFM
    ...    Applicability: none
    ...    Post-Conditions:  none 
    PUT Fault Management Individual Alarm
    Check HTTP Response Status Code Is    405
PATCH Fault Management Individual Alarm
AHMADABB's avatar
AHMADABB committed
    [Documentation]    Test ID: 7.3.5.2.4
    ...    Test title: PATCH Fault Management Individual Alarm
    ...    Test objective: The objective is to Modify an individual alarm resource and perform a JSON schema and content validation of the returned alarm data structure
mengxuan.zhao's avatar
mengxuan.zhao committed
    ...    Pre-conditions: The related alarm exists
    ...    Reference: Clause 7.4.3.3.4 - ETSI GS NFV-SOL 003 [1] v2.8.1
mengxuan.zhao's avatar
mengxuan.zhao committed
    ...    Config ID: Config_prod_VNFM
    ...    Applicability: none
    ...    Post-Conditions: none
    Check Precondition VNF fault management individual alarm Exists
    PATCH Fault Management Individual Alarm
    Check HTTP Response Status Code Is    200
    Check HTTP Response Body Json Schema Is  alarmModification
Modify an individual alarm resource - Precondition failed
AHMADABB's avatar
AHMADABB committed
    [Documentation]    Test ID: 7.3.5.2.5
    ...    Test title: Modify an individual alarm resource - Precondition failed
Giacomo Bernini's avatar
Giacomo Bernini committed
    ...    Test objective: The objective is to test that an individual alarm resource cannot be modified if the alarm is already in the state that is requested to be set
mengxuan.zhao's avatar
mengxuan.zhao committed
    ...    Pre-conditions: The related alarm exists
    ...    Reference: Clause 7.4.3.3.4 - ETSI GS NFV-SOL 003 [1] v2.8.1
mengxuan.zhao's avatar
mengxuan.zhao committed
    ...    Config ID: Config_prod_VNFM
    ...    Applicability: none
    ...    Post-Conditions: none
    Check Precondition VNF fault management individual alarm Exists  
    PATCH Fault Management Individual Alarm - precondition failed
    Check HTTP Response Status Code Is    409
    Check HTTP Response Body Json Schema Is  ProblemDetails
Modify an individual alarm resource - Conflict
AHMADABB's avatar
AHMADABB committed
    [Documentation]    Test ID: 7.3.5.2.6
    ...    Test title: Modify an individual alarm resource - Conflict
Giacomo Bernini's avatar
Giacomo Bernini committed
    ...    Test objective: The objective is to test that an individual alarm resource cannot be modified if the resource was modified by another entity
mengxuan.zhao's avatar
mengxuan.zhao committed
    ...    Pre-conditions: The related alarm exists
    ...    Reference: Clause 7.4.3.3.4 - ETSI GS NFV-SOL 003 [1] v2.8.1
mengxuan.zhao's avatar
mengxuan.zhao committed
    ...    Config ID: Config_prod_VNFM
    ...    Applicability: none
    ...    Post-Conditions: none
    Depends On Test    PATCH Fault Management Individual Alarm
    Check Precondition VNF fault management individual alarm Exists
    PATCH Fault Management Individual Alarm Conflict
    Check HTTP Response Status Code Is    412
    Check HTTP Response Body Json Schema Is     ProblemDetails
DELETE Alarm - Method not implemented
     [Documentation]    Test ID: 7.3.5.2.7
    ...    Test title: DELETE Alarm - Method not implemented
    ...    Test objective: The objective is to test that DELETE method is not allowed to for Fault management individual alarm on VNF 
Sana Zulfiqar's avatar
Sana Zulfiqar committed
    ...    Pre-conditions: none
    ...    Reference: Clause 7.4.3.3.5 - ETSI GS NFV-SOL 003 [1] v2.8.1
    ...    Config ID: Config_prod_VNFM
    ...    Applicability: none
    ...    Post-Conditions:  none
    DELETE Fault Management Individual Alarm
    Check HTTP Response Status Code Is    405
    
Get information about an fault management individual alarm - Not Found
    [Documentation]    Test ID: 7.3.5.2.8
    ...    Test title: Get information about an fault management individual alarm - Not Found
    ...    Test objective: The objective is to test that retrieval of information about an individual alarm fails when individual alarm is not present
    ...    Pre-conditions: The related alarm does not exists
    ...    Reference: Clause 7.4.3.3.2 - ETSI GS NFV-SOL 003 [1] v2.8.1
    ...    Config ID: Config_prod_VNFM
    ...    Applicability: none
    ...    Post-Conditions:  none 
    GET Fault Management Individual Alarm
    Check HTTP Response Status Code Is    404
    Check HTTP Response Body Json Schema Is    ProblemDetails