Newer
Older
*** Settings ***
# Suite setup Expect spec SOL003-VNFLifecycleManagement-API.yaml
Resource environment/variables.txt
Resource FaultManagement-APIKeyword.robot
Library REST ${VNFM_SCHEMA}://${VNFM_HOST}:${VNFM_PORT}
Library JSONLibrary
Library JSONSchemaLibrary schemas/
Library OperatingSystem
POST Alarms - Method not implemented
[Documentation] Test ID: 7.3.5.1.1
... Test title: POST Alarms - Method not implemented
... Test objective: The objective is to test that Post method is not allowed to create Fault management alarms on VNF
... Pre-conditions: none
... Reference: section 7.4.2.3.1 - SOL003 v2.4.1
... Config ID: Config_prod_VNFM
... Applicability: none
... Post-Conditions: none
Send POST request for fault management Alarms
Check HTTP Response Status Code Is 405
Get information about multiple alarms
[Documentation] Test ID: 7.3.5.1.2
... Test objective: The objective is to retrieve information about the alarm list and perform a JSON schema and content validation of the returned alarms data structure
... Pre-conditions: none
... Reference: section 7.4.2.3.2 - SOL003 v2.4.1
... Applicability: none
... Post-Conditions: none
GET Fault Management Alarms
Check HTTP Response Status Code Is 200
Check HTTP Response Body Json Schema Is Alarms
Get information about multiple alarms with filters
[Documentation] Test ID: 7.3.5.1.2
... Test title: Get information about multiple alarms with filters
... Test objective: The objective is to retrieve information about the alarm list and perform a JSON schema and content validation of the returned alarms data structure, and verify that the retrieved information matches the issued attribute-based filters
... Pre-conditions: none
... Reference: section 7.4.2.3.2 - SOL003 v2.4.1
... Applicability: none
... Post-Conditions: none
GET Fault Management Alarms With Filters
Check HTTP Response Status Code Is 200
Check HTTP Response Body Json Schema Is Alarms
Get information about multiple alarms Bad Request Invalid attribute-based filtering parameters
[Documentation] Test ID: 7.3.5.1.2
... Test title: The objective is to try to retrieve information about the alarm list and perform a JSON schema and content validation of the returned problem details data structure, and verify that the retrieved information matches the issued attribute-based filters
... Test objective: The objective is to retrieve information about the alarm list
... Pre-conditions:
... Reference: section 7.4.2.3.2 - SOL003 v2.4.1
... Config ID: Config_prod_VNFM
... Applicability:
... Post-Conditions:
GET Fault Management Alarms With Invalid Filters
Check HTTP Response Status Code Is 400
Check HTTP Response Body Json Schema Is ProblemDetails
PUT Alarms - Method not implemented
[Documentation] Test ID: 7.3.5.1.3
... Test title: PUT Alarms - Method not implemented
... Test objective: The objective is to test that PUT method is not allowed to for Fault management alarms on VNF
... Pre-conditions: none
... Reference: section 7.4.2.3.3 - SOL003 v2.4.1
... Config ID: Config_prod_VNFM
... Applicability: none
... Post-Conditions: none
PUT Fault management Alarms
Check HTTP Response Status Code Is 405
PATCH Alarms - Method not implemented
[Documentation] Test ID: 7.3.5.1.4
... Test title: PATCH Alarms - Method not implemented
... Test objective: The objective is to test that PATCH method is not allowed to for Fault management alarms on VNF
... Pre-conditions: none
... Reference: section 7.4.2.3.4 - SOL003 v2.4.1
... Config ID: Config_prod_VNFM
... Applicability: none
... Post-Conditions: none
PATCH Fault management Alarms
Check HTTP Response Status Code Is 405
DELETE Alarms - Method not implemented
[Documentation] Test ID: 7.3.5.1.5
... Test title: POST Alarms - Method not implemented
... Test objective: The objective is to test that DELETE method is not allowed for Fault management alarms on VNF
... Pre-conditions: none
... Reference: section 7.4.2.3.5 - SOL003 v2.4.1
... Config ID: Config_prod_VNFM
... Applicability: none
... Post-Conditions: none
DELETE Fault management Alarms
Check HTTP Response Status Code Is 405
Check Postcondition VNF fault management alarms Exists