0003966Part 06: TTCN-3 Control InterfaceClarificationpublic14-08-2008 15:2214-12-2008 10:57
ReporterThomas Deiß 
Assigned ToIna Schieferdecker 
PrioritynormalSeverityminorReproducibilityhave not tried
StatusclosedResolutionfixed 
PlatformOSOS Version
Product Version 
Target Versionv4.1.1 (published 2009-06)Fixed in Versionv4.1.1 (published 2009-06) 
Summary0003966: all/any component in tciStopTestComponentReq
DescriptionThe operation tciStopTestComponentReq (TE->SA) has a triComponentId as parameter. But this operation could also be used to indicate that all components have to be stopped. It is unclear which entity should resolve this to individual operations to stop specific test components.

This could either be the TE that contains the MTC or it could be the CH. In the latter case it is not quite clear how the information that all components are to be stopped is passed from the TE to the CH. A possibility in the second case is to use 'any' or 'all' as type name in the parameter of type triComponentId. Note that neither 'any' nor 'all' is a type name that can be defined in TTCN-3 code.

The same problem occurs for the operations
tciKillTestComponentReq (all)
tciTestComponentAliveReq (any/all)
tciTestComponentTerminatedReq (any/all)
tciTestComponentRunningReq (any/all)
tciTestComponentDoneReq (any/all)
tciDisconnectReq (all)
tciUnmapReq (all)

If the TE containing the MTC has to resolve the TTCN-3 operation into individual calls, then the TE has to forward each operation indicating a change of the status of a component or connection to this specific TE.
TagsNo tags attached.
Clause Reference(s)part 6, 7.3.3.2.15
Source (company - Author) Nokia Siemens Networks -- Thomas Deiß
Attached Filesdoc file icon CR3966_AnyAllComponent.doc [^] (24,576 bytes) 12-12-2008 15:29

- Relationships

-  Notes
(0007687)
Ina Schieferdecker (reporter)
12-12-2008 15:29

In order to enable an resolution of any/all within the CH, the CR should be resolved along the proposed solution as this requires no change to the execution interfaces in TTCN-3. The usage of TriComponentId should be extended as described. Please check.
(0007697)
Thomas Deiß (reporter)
12-12-2008 20:06

ok.

- Issue History
Date Modified Username Field Change
14-08-2008 15:22 Thomas Deiß New Issue
14-08-2008 15:22 Thomas Deiß Status new => assigned
14-08-2008 15:22 Thomas Deiß Assigned To => Ina Schieferdecker
14-08-2008 15:22 Thomas Deiß Clause Reference(s) => part 6, 7.3.3.2.15
14-08-2008 15:22 Thomas Deiß Source (company - Author) => Nokia Siemens Networks -- Thomas Deiß
17-08-2008 09:09 Ina Schieferdecker Project TTCN-3 Change Requests => Part 06: TTCN-3 Control Interface
17-08-2008 09:09 Ina Schieferdecker Target Version => Edition 4.1.1 (not yet published)
12-12-2008 15:29 Ina Schieferdecker File Added: CR3966_AnyAllComponent.doc
12-12-2008 15:29 Ina Schieferdecker Note Added: 0007687
12-12-2008 15:29 Ina Schieferdecker Resolution open => fixed
12-12-2008 15:29 Ina Schieferdecker Assigned To Ina Schieferdecker => Thomas Deiß
12-12-2008 20:06 Thomas Deiß Note Added: 0007697
12-12-2008 20:06 Thomas Deiß Assigned To Thomas Deiß => Ina Schieferdecker
14-12-2008 10:57 Ina Schieferdecker Status assigned => resolved
14-12-2008 10:57 Ina Schieferdecker Fixed in Version => Edition 4.1.1 (not yet published)
14-12-2008 10:57 Ina Schieferdecker Status resolved => closed


MantisBT 1.2.14 [^]
Copyright © 2000 - 2024 MantisBT Team
Powered by Mantis Bugtracker