*** Settings *** # Suite setup Expect spec SOL003-VNFLifecycleManagement-API.yaml Resource environment/variables.txt Resource FaultManagement-APIKeyword.robot Library REST ${VNFM_SCHEMA}://${VNFM_HOST}:${VNFM_PORT} Library OperatingSystem Library JSONLibrary Library JSONSchemaLibrary schemas/ Library DependencyLibrary *** Test Cases *** POST Alarm - Method not implemented [Documentation] Test ID: 7.3.5.2.1 ... Test title: POST Alarm - Method not implemented ... Test objective: The objective is to test that Post method is not allowed to create Fault management individual alarm on VNF ... Pre-conditions: none ... Reference: clause 7.4.3.3.1 - ETSI GS NFV-SOL 003 [1] v2.4.1 ... Config ID: Config_prod_VNFM ... Applicability: none ... Post-Conditions: none Send POST request for fault management Individual Alarm Check HTTP Response Status Code Is 405 Get information about an fault management individual alarm [Documentation] Test ID: 7.3.5.2.2 ... Test title: Get information about an fault management individual alarm ... Test objective: The objective is to retrieve information about an individual alarm and perform a JSON schema and content validation of the returned alarm data structure ... Pre-conditions: The related alarm exists ... Reference: clause 7.4.3.3.2 - ETSI GS NFV-SOL 003 [1] v2.4.1 ... Config ID: Config_prod_VNFM ... Applicability: none ... Post-Conditions: none GET Fault Management Individual Alarm Check HTTP Response Status Code Is 200 Check HTTP Response Body Json Schema Is alarm PUT Alarm - Method not implemented [Documentation] Test ID: 7.3.5.2.3 ... Test title: PUT Alarm - Method not implemented ... Test objective: he objective is to test that PUT method is not allowed to for Fault management individual alarm on VNF ... Pre-conditions: The related alarm exists ... Reference: clause 7.4.3.3.3 - ETSI GS NFV-SOL 003 [1] v2.4.1 ... Config ID: Config_prod_VNFM ... Applicability: none ... Post-Conditions: none PUT Fault Management Individual Alarm Check HTTP Response Status Code Is 405 PATCH Fault Management Individual Alarm [Documentation] Test ID: 7.3.5.2.4 ... Test title: PATCH Fault Management Individual Alarm ... Test objective: The objective is to Modify an individual alarm resource and perform a JSON schema and content validation of the returned alarm data structure ... Pre-conditions: The related alarm exists ... Reference: clause 7.4.3.3.4 - ETSI GS NFV-SOL 003 [1] v2.4.1 ... Config ID: Config_prod_VNFM ... Applicability: none ... Post-Conditions: none Check Postcondition VNF fault management individual alarm Exists PATCH Fault Management Individual Alarm Check HTTP Response Status Code Is 200 Check HTTP Response Body Json Schema Is alarmModification Modify an individual alarm resource - Precondition failed [Documentation] Test ID: 7.3.5.2.5 ... Test title: Modify an individual alarm resource - Precondition failed ... Test objective: The objective is to test that an individual alarm resource cannot be modified if the alarm is already in the state that is requested to be set ... Pre-conditions: The related alarm exists ... Reference: clause 7.4.3.3.4 - ETSI GS NFV-SOL 003 [1] v2.4.1 ... Config ID: Config_prod_VNFM ... Applicability: none ... Post-Conditions: none Check Postcondition VNF fault management individual alarm Exists PATCH Fault Management Individual Alarm - precondition failed Check HTTP Response Status Code Is 409 Check HTTP Response Body Json Schema Is ProblemDetails Modify an individual alarm resource - Conflict [Documentation] Test ID: 7.3.5.2.6 ... Test title: Modify an individual alarm resource - Conflict ... Test objective: The objective is to test that an individual alarm resource cannot be modified if the resource was modified by another entity ... Pre-conditions: The related alarm exists ... Reference: clause 7.4.3.3.4 - ETSI GS NFV-SOL 003 [1] v2.4.1 ... Config ID: Config_prod_VNFM ... Applicability: none ... Post-Conditions: none Depends On Test PATCH Fault Management Individual Alarm Check Postcondition VNF fault management individual alarm Exists PATCH Fault Management Individual Alarm Conflict Check HTTP Response Status Code Is 412 Check HTTP Response Body Json Schema Is ProblemDetails DELETE Alarm - Method not implemented [Documentation] Test ID: 7.3.5.2.7 ... Test title: DELETE Alarm - Method not implemented ... Test objective: The objective is to test that DELETE method is not allowed to for Fault management individual alarm on VNF ... Pre-conditions: nona ... Reference: clause 7.4.3.3.5 - ETSI GS NFV-SOL 003 [1] v2.4.1 ... Config ID: Config_prod_VNFM ... Applicability: none ... Post-Conditions: The individual alarm still exists DELETE Fault Management Individual Alarm Check HTTP Response Status Code Is 405 Check Postcondition VNF fault management individual alarm Exists