Commit 0af5a608 authored by Yann Garcia's avatar Yann Garcia

Start MEO/UEAPPCTX implementation, bug fixed in PlatBandwidthManager.robot

parent 302a6968
......@@ -11,6 +11,80 @@ Library REST ${MEC-APP_SCHEMA}://${MEC-APP_HOST}:${MEC-APP_PORT} ssl_v
*** Test Cases ***
Creation of the application context
[Documentation] TC_MEC_MEO_UEAPPCTX_001_OK
... Check that the IUT acknowledges the creation of the application context when requested by an UE Application
... Reference ETSI GS MEC 014 V1.1.1, clause 7.4.3.4
... Reference https://forge.etsi.org/gitlab/mec/gs016-ue-app-api/blob/master/UEAppInterfaceApi.yaml#/definitions/AppContext
Create application context ${CREATE_APP_CTX}
Check HTTP Response Status Code Is 20
Check HTTP Response Body Json Schema Is AppContext
Should Be True ${response['body']['appContext']['appInfo']['appName']} == ${APP_NAME}
Creation of the application context with wrong parameters
[Documentation] TC_MEC_MEO_UEAPPCTX_001_BR
... Check that the IUT responds with an error when a request with incorrect parameters is sent by a MEC Application
... Reference ETSI GS MEC 014 V1.1.1, clause 7.4.3.4
... Reference https://forge.etsi.org/gitlab/mec/gs016-ue-app-api/blob/master/UEAppInterfaceApi.yaml#/definitions/AppContext
Create application context ${CREATE_APP_CTX}
Check HTTP Response Status Code Is 400
Check ProblemDetails 400
Update of the application context
[Documentation] TC_MEC_MEO_UEAPPCTX_002_OK
... Check that the IUT updates the application callback reference when commanded by an UE Application
... Reference ETSI GS MEC 014 V1.1.1, clause 7.5.3.2
... Reference https://forge.etsi.org/gitlab/mec/gs016-ue-app-api/blob/master/UEAppInterfaceApi.yaml#/definitions/AppContext
# Preamble
Should Be True ${PIC_MEC_SYSTEM} == 1
Should Be True ${PIC_SERVICES} == 1
Create an application context
# Test Body
${CREATE_APP_CTX['callbackReference']}= ${CALLBACK_REFERENCE_1}
Update application context ${CREATE_APP_CTX}
Check HTTP Response Status Code Is 204
Check HTTP Response Body Json Schema Is AppContext
Should Be True ${response['body']['appContext']['callbackReference']} == ${CALLBACK_REFERENCE_1}
Update of the application context with wrong parameters
[Documentation] TC_MEC_MEO_UEAPPCTX_002_BR
... Check that the IUT responds with an error when a request with incorrect parameters is sent by a MEC Application
... Reference ETSI GS MEC 014 V1.1.1, clause 7.5.3.2
... Reference https://forge.etsi.org/gitlab/mec/gs016-ue-app-api/blob/master/UEAppInterfaceApi.yaml#/definitions/AppContext
# Preamble
Should Be True ${PIC_MEC_SYSTEM} == 1
Should Be True ${PIC_SERVICES} == 1
Create an application context
# Test Body
${CREATE_APP_CTX['callbackReference']}= '' # Empty string
Update application context ${CREATE_APP_CTX}
Check HTTP Response Status Code Is 400
Check ProblemDetails 400
*** Keywords ***
Create application context
[Arguments] ${content}
Should Be True ${PIC_MEC_SYSTEM} == 1
Should Be True ${PIC_SERVICES} == 1
Set Headers {"Accept":"application/json"}
Set Headers {"Content-Type":"application/json"}
Set Headers {"Authorization":"${TOKEN}"}
Set Headers {"Content-Length":"0"}
Post /exampleAPI/mx2/v2/app_contexts ${content}
${output}= Output response
Set Suite Variable ${response} ${output}
Update application context
[Arguments] ${context_id} ${content}
Set Headers {"Accept":"application/json"}
Set Headers {"Content-Type":"application/json"}
Set Headers {"Authorization":"${TOKEN}"}
Set Headers {"Content-Length":"0"}
Put /exampleAPI/mx2/v2/app_contexts/${context_id} ${content}
${output}= Output response
Set Suite Variable ${response} ${output}
......@@ -4,3 +4,10 @@ ${MEC-APP_SCHEMA} http
#${MEC-APP_HOST} 127.0.0.1
${MEC-APP_HOST} 192.168.56.1
${MEC-APP_PORT} 8081
${APP_CTX_ID} appCtx01
${UE_APP_ID} ueIdAppCtx01
${APP_NAME} MyWornderfulApp
${WRONG_CREATE_APP_CTX} UnknownApp
${CALLBACK_REFERENCE} http://www.acme.com/MyWonderfulApp/v1
${CALLBACK_REFERENCE_1} http://www.acme.com/MyWonderfulApp/v2
${CREATE_APP_CTX} { "contextId": "${CREATE_APP_CTX}", "associateUeAppId": "${UE_APP_ID}", "callbackReference": "${CALLBACK_REFERENCE}", "appInfo": { "appName": "${APP_NAME}", "appProvider": "ACME & Co", "appSoftVersion": "1.0.0.1", "appDescription": "This is a wonderful test application", "referenceURL": "http://www.acme.com/MyWonderfulPackage", "appPackageSource": "MyWonderfulPackage" } }
*** Settings ***
Resource ../environment/variables.txt
Resource ../../../pics.txt
Resource ../../../GenericKeywords.robot
Library REST ${MEC-APP_SCHEMA}://${MEC-APP_HOST}:${MEC-APP_PORT} ssl_verify=false
Library JSONSchemaLibrary schemas/
*** Keywords ***
*** Settings ***
Resource ../environment/variables.txt
Resource ../../../pics.txt
Resource ../../../GenericKeywords.robot
Library REST ${MEC-APP_SCHEMA}://${MEC-APP_HOST}:${MEC-APP_PORT} ssl_verify=false
Library JSONSchemaLibrary schemas/
*** Keywords ***
Create an application context
Should Be True ${PIC_MEC_SYSTEM} == 1
Should Be True ${PIC_SERVICES} == 1
Set Headers {"Accept":"application/json"}
Set Headers {"Content-Type":"application/json"}
Set Headers {"Authorization":"${TOKEN}"}
Set Headers {"Content-Length":"0"}
Post /exampleAPI/mx2/v2/app_contexts ${CREATE_APP_CTX}
${output}= Output response
Set Suite Variable ${response} ${output}
Check HTTP Response Status Code Is 201
Check HTTP Response Body Json Schema Is AppContext
Set Suite Variable ${APP_CTX_ID} ${response['body']['contextId']
Should Not Be Empty ${APP_CTX_ID}
......@@ -209,8 +209,8 @@ Request to unregister bandwidth Management Service
Request to unregister bandwidth Management Service with wrong parameters
[Documentation] TC_MEC_SRV_BWA_006_OK
... Check that the IUT unregisters from the Bandwidth Management Service when commanded by a MEC Application
[Documentation] TC_MEC_SRV_BWA_006_NF
... Check that the IUT responds with an error when a request for an unknown URI is sent by a MEC Application
... Reference ETSI GS MEC 015 V1.1.1, clause 8.3.3.5
... Reference https://forge.etsi.org/rep/mec/gs015-bandwith-mgmt-api/blob/master/BwManagementApi.json
# Preamble
......
Markdown is supported
0% or
You are about to add 0 people to the discussion. Proceed with caution.
Finish editing this message first!
Please register or to comment