 *  @author     STF 574
 *  @version    $Id$
 *  @desc       This module provides the TP behaviour functions at Mw interface at S-CSCF/IBCF
 */

module AtsImsIot_TP_behavior_MX {

    // LibIms
    import from LibIms_Templates all;
    import from LibIms_UpperTester all;
    // LibIot
    import from LibIot_TypesAndValues all;
    import from LibIot_Functions all;
    import from LibIot_TestInterface all;
    import from LibIot_PIXITS all;
    // LibSip
    import from LibSip_SIPTypesAndValues all;
    import from LibSip_Templates all;
    import from LibSip_Common all;
    import from LibSip_SDPTypes all;
    // LibMsrp
    import from LibMsrp_TypesAndValues all;
    import from LibMsrp_Functions all;
    import from LibMsrp_Templates all;
    // AtsImsIot
    import from AtsImsIot_TestSystem all;
    import from AtsImsIot_Templates all;
    import from AtsImsIot_Templates_MX all;
    import from AtsImsIot_TypesAndValues all;
    import from AtsImsIot_Functions all;

    group imsInvite {
        
        /**
         * @desc "Verify that the E-CSCF successfully processes an initial INVITE from the P-CSCF and routes the request to the IBCF for a PSAP in another network."
         * Reference 
         *     "ETSI TS 124 229 [1], Clauses 5.11.2"
         * Config Id CF_VxLTE_INT
         * PICS Selection NONE
         * Initial conditions with {
         *     the IMS_E_CSCF entity supportsRoutingTo the IMS_IBCF_A
         * }
         * Expected behaviour
         *     ensure that {
         *         when {
         *             the IMS_E_CSCF entity receives an INVITE containing
         *                 From indicating value PX_UE_A_SIP_URI,
         *                 To indicating value PX_SIP_EMERGENCY_SERVICE_URN,
         *                 CallId indicating value PX_UE_A_CALLID,
         *                 Via indicating value PX_P_CSCF_A_VIA,
         *                 Route indicating value PX_E_CSCF_SERVICE_ROUTE, // 5.2.10.3 1B) option is assumed
         *                 PAssertedIdentity,
         *                 MessageBody;
         *             from the IMS_P_CSCF_A entity
         *         }
         *         then {
         *             the IMS_E_CSCF entity sends an INVITE containing
         *                 From indicating value PX_UE_A_SIP_URI,
         *                 To indicating value PX_SIP_EMERGENCY_SERVICE_URN,
         *                 CallId indicating value PX_UE_A_CALLID,
         *                 Via indicating value PX_E_CSCF_VIA,
         *                 Route indicating value PX_PSAP_SERVICE_ROUTE_IM_CN,
         *                 RecordRoute PX_E_CSCF_SERVICE_ROUTE,
         *                 PChargingVector containing
         *                     not term_ioi_parameter,
         *                     orig_ioi_parameter
         *                         indicating value "Operator Identifier Of ImsA";,
         *                 MessageBody;
         *              to the IMS_IBCF_A entity
         *         }
         *     }
        */
        function f_mtc_check_TP_MX_ECSCF_ECO_INVITE_01(
                                                       in SipInterfaceMonitor p_monitorCompRef,
                                                       in boolean p_checkMessage := false,
                                                       out SipMessage p_sip
                                                       ) runs on ImsTestCoordinator {
            if (isvalue(p_monitorCompRef)) {
                var ImsUserInfo v_userInfoA := f_getTelUserId(PX_EUT_A_EMERGENCY);
                var ImsUserInfo v_psapInfo  := f_getSipUserId(PX_PSAP);
                
                // Check the INVITE
                p_monitorCompRef.start(
                                       f_Iot_Sip_receive(
                                                        { mw_SipRequest(mw_TP_MX_ECSCF_INVITE_01(
                                                                                                 -, // FIXME Set expected value
                                                                                                 mw_From_AddrUnion_TelUrl(-), // v_userInfoA.publicId
                                                                                                 mw_To_AddrUnion_TelUrl(-) // v_psapInfo.publicId
                                                                                                 ))
                                                        },
                                                        { mw_SipRequest(mw_INVITE_Request_Base) },
                                                        {0, omit},
                                                        "TP_MX_ECSCF_ECO_INVITE_01 - Request",
                                                        true,
                                                        p_checkMessage
                                                        )
                                       );
                p_monitorCompRef.done;
                // Retrieve messge
                f_getSipMsgFromMonitor(p_monitorCompRef, p_sip);
                log("##### p_sip: ", p_sip);
            }
        } // End of function f_mtc_check_TP_MX_ECSCF_ECO_INVITE_01

        /**
         * @desc "Verify that the E-CSCF successfully processes an initial INVITE from the P-CSCF and routes the request to the IBCF for a PSAP in another network and includes the LRF provided URI in the Route header."
         * Reference 
         *     "ETSI TS 124 229 [1], Clauses 5.11.2"
         * Config Id CF_VxLTE_INT
         * PICS Selection NONE
         * Initial conditions with {
         *     the IMS_E_CSCF entity supportsRoutingTo the IMS_LRF and
         *     the IMS_E_CSCF entity hasSentINVITETo the IMS_LRF and
         *     the IMS_E_CSCF entity supportsRoutingTo the IMS_IBCF_A
         * }
         * Expected behaviour
         *     ensure that {
         *         when {
         *             the IMS_E_CSCF entity receives an r_3xx_Any containing
         *                 Contact indicating value LRF_provided_SIP_URI;
         *             from the IMS_LRF entity
         *         }
         *         then {
         *             the IMS_E_CSCF entity sends an INVITE containing
         *                 From indicating value PX_UE_A_SIP_URI,
         *                 To indicating value PX_SIP_EMERGENCY_SERVICE_URN,
         *                 CallId indicating value PX_UE_A_CALLID,
         *                 Via indicating value PX_E_CSCF_VIA,
         *                 Route indicating value PX_PSAP_SERVICE_ROUTE_IM_CN,
         *                 RecordRoute PX_E_CSCF_SERVICE_ROUTE,
         *                 PChargingVector containing
         *                     not term_ioi_parameter,
         *                     orig_ioi_parameter
         *                         indicating value "Operator Identifier Of ImsA";,
         *                 MessageBody;
         *              to the IMS_IBCF_A entity
         *         }
         *     }
        */
        function f_mtc_check_TP_MX_ECSCF_ECO_INVITE_02(
                                                       in SipInterfaceMonitor p_monitorCompRef,
                                                       in boolean p_checkMessage := false,
                                                       out SipMessage p_sip
                                                       ) runs on ImsTestCoordinator {
            if (isvalue(p_monitorCompRef)) {
                var ImsUserInfo v_userInfoA := f_getTelUserId(PX_EUT_A_EMERGENCY);
                var ImsUserInfo v_psapInfo  := f_getSipUserId(PX_PSAP);
                
                // Check the INVITE
                p_monitorCompRef.start(
                                       f_Iot_Sip_receive(
                                                        { mw_SipRequest(mw_TP_MX_ECSCF_INVITE_02(
                                                                                                 -, // FIXME Set expected value
                                                                                                 mw_From_AddrUnion_TelUrl(-), // v_userInfoA.publicId
                                                                                                 mw_To_AddrUnion_TelUrl(-) // v_psapInfo.publicId
                                                                                                 ))
                                                        },
                                                        { mw_SipRequest(mw_INVITE_Request_Base) },
                                                        {0, omit},
                                                        "TP_MX_ECSCF_ECO_INVITE_02 - Request",
                                                        true,
                                                        p_checkMessage
                                                        )
                                       );
                p_monitorCompRef.done;
                // Retrieve messge
                f_getSipMsgFromMonitor(p_monitorCompRef, p_sip);
                log("##### p_sip: ", p_sip);
            }
        } // End of function f_mtc_check_TP_MX_ECSCF_ECO_INVITE_02

        /**
         * @desc "Verify that the E-CSCF successfully processes a callback INVITE from the PSAP in another network over the IBCF  and routes the request to the P-CSCF."
         * Reference 
         *     "ETSI TS 124 229 [1], Clauses 5.11.2"
         * Config Id CF_VxLTE_INT
         * PICS Selection NONE
         * Initial conditions with {
         *     the IMS_E_CSCF entity supportsRoutingTo the IMS_IBCF_A
         * }
         * Expected behaviour
         *     ensure that {
         *         when {
         *             the IMS_E_CSCF entity receives an INVITE containing
         *                 From indicating value PX_UE_A_SIP_URI,
         *                 To indicating value PX_SIP_EMERGENCY_SERVICE_URN,
         *                 CallId indicating value PX_UE_A_CALLID,
         *                 Via indicating value PX_P_CSCF_A_VIA,
         *                 Route indicating value PX_E_CSCF_SERVICE_ROUTE, // 5.2.10.3 1B) option is assumed
         *                 PAssertedIdentity,
         *                 MessageBody;
         *             from the IMS_IBCF_A entity
         *         }
         *         then {
         *             the IMS_E_CSCF entity sends an INVITE containing
         *                 From indicating value PX_UE_A_SIP_URI,
         *                 To indicating value PX_SIP_EMERGENCY_SERVICE_URN,
         *                 CallId indicating value PX_UE_A_CALLID,
         *                 Via indicating value PX_E_CSCF_VIA,
         *                 Route indicating value PX_PSAP_SERVICE_ROUTE_IM_CN,
         *                 RecordRoute PX_E_CSCF_SERVICE_ROUTE,
         *                 PChargingVector containing
         *                     not term_ioi_parameter,
         *                     orig_ioi_parameter
         *                         indicating value "Operator Identifier Of ImsA";,
         *                 MessageBody;
         *              to the IMS_P_CSCF_A entity
         *         }
         *     }
        */
        function f_mtc_check_TP_MX_ECSCF_ECO_INVITE_03(
                                                       in SipInterfaceMonitor p_monitorCompRef,
                                                       in boolean p_checkMessage := false,
                                                       out SipMessage p_sip
                                                       ) runs on ImsTestCoordinator {
            if (isvalue(p_monitorCompRef)) {
                var ImsUserInfo v_userInfoA := f_getTelUserId(PX_EUT_A_EMERGENCY);
                var ImsUserInfo v_psapInfo  := f_getSipUserId(PX_PSAP);
                
                // Check the INVITE
                p_monitorCompRef.start(
                                       f_Iot_Sip_receive(
                                                        { mw_SipRequest(mw_TP_MX_ECSCF_INVITE_03(
                                                                                                 -, // FIXME Set expected value
                                                                                                 mw_From_AddrUnion_TelUrl(-), // v_userInfoA.publicId
                                                                                                 mw_To_AddrUnion_TelUrl(-) // v_psapInfo.publicId
                                                                                                 ))
                                                        },
                                                        { mw_SipRequest(mw_INVITE_Request_Base) },
                                                        {0, omit},
                                                        "TP_MX_ECSCF_ECO_INVITE_03 - Request",
                                                        true,
                                                        p_checkMessage
                                                        )
                                       );
                p_monitorCompRef.done;
                // Retrieve messge
                f_getSipMsgFromMonitor(p_monitorCompRef, p_sip);
                log("##### p_sip: ", p_sip);
            }
        } // End of function f_mtc_check_TP_MX_ECSCF_ECO_INVITE_03

    } // End of group imsInvite

    group ims100Trying {
        
        function f_mtc_check_TP_MX_ECSCF_ECO_100Trying_01(
                                                          in SipInterfaceMonitor p_monitorCompRef,
                                                          in boolean p_checkMessage := false,
                                                          in SipMessage p_sip
                                                          ) runs on ImsTestCoordinator {
            if (isvalue(p_monitorCompRef)) {
                // Check the 100 TRYING
                p_monitorCompRef.start(
                                       f_Iot_Sip_receive(
                                                         { mw_SipResponse(mw_TP_MX_ECSCF_100Trying_01(
                                                                                                      p_sip.request.msgHeader.cSeq,
                                                                                                      p_sip.request.msgHeader.fromField,
                                                                                                      p_sip.request.msgHeader.toField
                                                                          )) 
                                                         },
                                                         { mw_SipResponse(mw_100Trying_Base) },
                                                         { 0, omit },
                                                         "TP_MX_ECSCF_100Trying_01",
                                                         false,
                                                         p_checkMessage
                                                         )
                                        );
                p_monitorCompRef.done;
            }
        } // End of function f_mtc_check_TP_MX_ECSCF_ECO_100Trying_01
274 275 276 277 278 279 280 281 282 283 284 285 286 287 288 289 290 291 292 293 294 295 296 297 298 299 300 301 302 303 304 305 306 307 308 309 310 311 312 313 314 315 316 317 318 319 320 321 322 323 324 325 326 327 328 329 330 331 332 333 334 335 336 337 338 339 340 341 342 343 344 345 346 347 348 349 350 351 352 353 354 355 356 357 358 359 360 361 362 363 364 365 366 367 368 369 370 371 372 373 374 375 376 377 378 379 380 381 382 383 384 385 386 387 388 389 390 391 392 393 394 395 396 397 398 399 400 401 402 403 404 405 406 407 408 409 410 411 412 413 414 415 416 417 418 419 420 421 422 423 424 425 426 427 428 429 430 431 432 433 434 435 436 437 438 439 440 441 442 443 444 445 446 447 448 449 450 451 452 453 454 455 456 457 458 459 460 461 462 463 464 465 466 467 468 469 470 471 472 473 474 475 476 477 478 479 480 481 482 483 484 485 486 487 488 489 490 491 492 493 494 495 496 497 498 499 500 501 502 503 504 505 506 507 508 509 510 511 512 513 514 515 516 517 518 519 520 521 522 523 524 525 526 527 528 529 530 531 532 533 534 535 536 537 538 539 540 541 542 543 544 545 546 547 548 549 550 551 552 553 554 555 556 557 558 559 560 561 562 563 564 565 566 567 568 569 570 571 572 573 574 575 576 577 578 579 580 581 582 583 584 585 586 587 588 589 590 591 592 593 594 595 596 597 598 599 600 601 602 603 604 605 606 607 608 609 610 611 612 613 614 615 616 617 618 619 620 621 622 623 624 625 626 627 628 629 630 631 632 633 634 635 636 637 638 639 640 641 642 643 644 645 646 647 648 649 650 651 652 653 654 655 656 657 658 659 660 661 662 663 664 665 666 667 668 669 670 671 672 673 674 675 676 677 678 679 680 681 682 683 684 685 686 687 688 689 690 691 692 693 694 695 696 697 698 699 700 701 702 703 704 705 706 707 708 709 710 711 712 713 714 715 716 717 718 719 720 721 722 723 724 725 726 727 728 729 730 731 732 733 734 735 736 737 738 739 740 741 742 743 744 745 746 747 748 749 750 751 752 753 754 755 756 757 758 759 760 761 762 763 764 765 766 767 768 769 770 771 772 773 774 775 776 777 778 779 780 781 782 783 784 785 786 787 788 789 790 791 792 793 794 795 796 797 798 799 800 801 802 803 804 805 806 807 808 809 810 811 812 813 814 815 816 817 818 819 820 821 822 823
        
    } // End of group ims100Trying

    group ims180Ringing {
        
        function f_mtc_check_TP_MX_ECSCF_ECO_180RINGING_01(
                                                           in SipInterfaceMonitor p_monitorCompRef,
                                                           in boolean p_checkMessage := false,
                                                           in SipMessage p_sip
                                                           ) runs on ImsTestCoordinator {
            if (isvalue(p_monitorCompRef)) {
                // Check the 180 RINGING
                p_monitorCompRef.start(
                                       f_Iot_Sip_receive(
                                                         { mw_SipResponse(mw_TP_MX_ECSCF_180Ringing_01(
                                                                                                       p_sip.request.msgHeader.cSeq,
                                                                                                       p_sip.request.msgHeader.fromField,
                                                                                                       mw_To_NameAddr_TelUrl(
                                                                                                                             -,
                                                                                                                             p_sip.request.msgHeader.toField.addressField.addrSpecUnion.components.tel.subscriber
                                                                          ))) 
                                                         },
                                                         { mw_SipResponse(mw_180Ringing_Base) },
                                                         { 0, omit },
                                                         "TP_MX_ECSCF_180RINGING_01",
                                                         false,
                                                         p_checkMessage
                                                         )
                                        );
                p_monitorCompRef.done;
            }
        } // End of function f_mtc_check_TP_MX_ECSCF_ECO_180RINGING_01
        
    } // End of group ims180Ringing

    group ims183SessionProgress {
        
        function f_mtc_check_TP_MX_ECSCF_ECO_183SESSION_PROGRESS_01(
                                                                    in SipInterfaceMonitor p_monitorCompRef,
                                                                    in boolean p_checkMessage := false,
                                                                    in SipMessage p_sip
                                                                    ) runs on ImsTestCoordinator {
            if (isvalue(p_monitorCompRef)) {
                // Check the 183 SESSION_PROGRESS
                p_monitorCompRef.start(
                                       f_Iot_Sip_receive(
                                                         { mw_SipResponse(mw_TP_MX_ECSCF_183SessionProgress_01(
                                                                                                               p_sip.request.msgHeader.cSeq,
                                                                                                               p_sip.request.msgHeader.fromField,
                                                                                                               p_sip.request.msgHeader.toField
                                                                                                               )) 
                                                         },
                                                         { mw_SipResponse(mw_183SessionProgress_Base) },
                                                         { 0, omit },
                                                         "TP_MX_ECSCF_183SESSION_PROGRESS_01",
                                                         false,
                                                         p_checkMessage
                                                         )
                                        );
                p_monitorCompRef.done;
            }
        } // End of function f_mtc_check_TP_MX_ECSCF_ECO_183SESSION_PROGRESS_01

    } // End of group ims183SessionProgress
    
    group ims200Ok {
        
        function f_mtc_check_TP_MX_ECSCF_ECO_200OK_01(
                                                      in SipInterfaceMonitor p_monitorCompRef,
                                                      in boolean p_checkMessage := false,
                                                      in SipMessage p_sip
                                                      ) runs on ImsTestCoordinator {
            if (isvalue(p_monitorCompRef)) {
                var ImsUserInfo v_userInfoB := f_getSipUserId(PX_EUT_B);
                
                // Check the 200 OK
                p_monitorCompRef.start(
                                       f_Iot_Sip_receive(
                                                         { mw_SipResponse(mw_200OK(
                                                                                   p_sip.request.msgHeader.cSeq,
                                                                                   p_sip.request.msgHeader.callId,
                                                                                   p_sip.request.msgHeader.fromField,
                                                                                   (
                                                                                      mw_To_NameAddr_TelUrl({quotedString:=f_getSipUserId(PX_EUT_B).publicId}),
                                                                                      mw_To_AddrUnion_TelUrl(f_getTelUserId(PX_EUT_B).publicId),
                                                                                      p_sip.request.msgHeader.toField
                                                                                    )
                                                                                   )) 
                                                         },
                                                         { mw_SipResponse(mw_200OK_Base) },
                                                         { 0, omit },
                                                         "TP_MX_ECSCF_200OK_01",
                                                         false,
                                                         p_checkMessage
                                                         )
                                        );
                p_monitorCompRef.done;
                
            }
        } // End of function f_mtc_check_TP_MX_ECSCF_ECO_200OK_01
        
    } // End of group ims200Ok
    
    group imsAck {
        
        function f_mtc_check_TP_MX_ECSCF_ECO_ACK_01(
                                                    in SipInterfaceMonitor p_monitorCompRef,
                                                    in boolean p_checkMessage := false,
                                                    in SipMessage p_sip
                                                    ) runs on ImsTestCoordinator {
            if (isvalue(p_monitorCompRef)) {
                // Check the ACK
                p_monitorCompRef.start(
                                       f_Iot_Sip_receive(
                                                         { mw_SipRequest(mw_TP_MX_ECSCF_ACK_01(
                                                                                               p_sip.request.msgHeader.callId,
                                                                                               p_sip.request.msgHeader.cSeq,
                                                                                               -, // FIXME To be set
                                                                                               p_sip.request.msgHeader.fromField,
                                                                                               p_sip.request.msgHeader.toField
                                                                                               )) 
                                                         },
                                                         { mw_SipRequest(mw_ACK_Request_Base) },
                                                         { 0, omit },
                                                         "TP_MX_ECSCF_ECO_ACK_01 - Request",
                                                         false,
                                                         p_checkMessage
                                                         )
                                        );
                p_monitorCompRef.done;
            }
        } // End of function f_mtc_check_TP_MX_ECSCF_ECO_ACK_01
        
    } // End of group imsAck
    
    group imsBye {
        
        /**
         * @desc Verify that the E-CSCF successfully processes a BYE from the P-CSCF for an Emergency Call and routes the request to the IBCF for a PSAP in another network
         * Initial conditions with {
         *     the IMS_E_CSCF entity supportsRoutingTo the IMS_IBCF_A and
         *     the UE_A entity previouslyEstablishedEmergencyCallWith the PSAP via IMS_IBCF_A
         * }
         * 
         * Expected behaviour
         * ensure that {
         *     when {
         *         the IMS_E_CSCF_A entity receives a BYE containing
         *             From indicating value PX_UE_A_SIP_URI,
         *             To indicating value PX_SIP_EMERGENCY_SERVICE_URN,
         *             CallId indicating value PX_UE_A_CALLID,
         *             Via indicating value PX_UE_A_VIA,
         *             Route indicating value PX_UE_A_SERVICE_ROUTE
         *             ;
         *         from the IMS_P_CSCF_A entity
         *     }
         *     then {
         *         the IMS_E_CSCF_A entity sends a BYE containing
         *             From indicating value PX_UE_A_SIP_URI,
         *             To indicating value PX_SIP_EMERGENCY_SERVICE_URN,
         *             CallId indicating value PX_UE_A_CALLID,
         *             Via indicating value PX_UE_A_VIA,
         *             Route indicating value PX_UE_A_SERVICE_ROUTE;
         *         to the IMS_IBCF_A entity
         *         }
         *     }
         */
        function f_mtc_check_TP_MX_ECSCF_ECO_BYE_01(
                                                    in SipInterfaceMonitor p_monitorCompRef,
                                                    in boolean p_checkMessage := false,
                                                    inout SipMessage p_sip
                                                    ) runs on ImsTestCoordinator {
            if (isvalue(p_monitorCompRef)) {
                // Check the BYE
                p_monitorCompRef.start(
                                       f_Iot_Sip_receive(
                                                         { mw_SipRequest(mw_TP_MX_ECSCF_BYE_01(
                                                                                               p_sip.request.msgHeader.callId,
                                                                                               -, // New CSeq,
                                                                                               -, // FIXME To be set
                                                                                               p_sip.request.msgHeader.fromField,
                                                                                               p_sip.request.msgHeader.toField
                                                                                               )) 
                                                         },
                                                         { mw_SipRequest(mw_BYE_Request_Base) },
                                                         { 0, omit },
                                                         "TP_MX_ECSCF_ECO_BYE_01 - Request",
                                                         true,
                                                         p_checkMessage
                                                         )
                                        );
                p_monitorCompRef.done;
                // Retrieve messge
                f_getSipMsgFromMonitor(p_monitorCompRef, p_sip);
            }
        } // End of function f_mtc_check_TP_MX_ECSCF_ECO_BYE_01

        /**
         * @desc Verify that the E-CSCF successfully processes a BYE from the IBCF for a PSAP in another network for an Emergency Call and routes the request to the P-CSCF
         * Initial conditions with {
         *     the IMS_E_CSCF entity supportsRoutingTo the IM_CN and
         *     the UE_A entity previouslyEstablishedEmergencyCallWith the PSAP
         * }
         * 
         * Expected behaviour
         * ensure that {
         *     when {
         *         the IMS_E_CSCF_A entity receives a BYE containing
         *             From indicating value PX_PSAP_SIP_URI,
         *             To indicating value PX_UE_A_SIP_URI,
         *             CallId indicating value PX_PSAP_SIP_URI,
         *             Via indicating value PX_PSAP_VIA;
         *         from the IMS_IBCF_A entity
         *     }
         *     then {
         *         the IMS_E_CSCF_A entity sends a BYE containing
         *             From indicating value PX_PSAP_SIP_URI,
         *             To indicating value PX_UE_A_SIP_URI,
         *             CallId indicating value PX_PSAP_SIP_URI,
         *             Via indicating value PX_PSAP_VIA;
         *         to the IMS_P_CSCF_A entity
         *         }
         *     }
         */
        function f_mtc_check_TP_MX_ECSCF_ECO_BYE_02(
                                                    in SipInterfaceMonitor p_monitorCompRef,
                                                    in boolean p_checkMessage := false,
                                                    inout SipMessage p_sip
                                                    ) runs on ImsTestCoordinator {
            if (isvalue(p_monitorCompRef)) {
                // Check the BYE
                p_monitorCompRef.start(
                                       f_Iot_Sip_receive(
                                                         { mw_SipRequest(mw_TP_MX_ECSCF_BYE_02(
                                                                                               p_sip.request.msgHeader.callId,
                                                                                               -, // New CSeq,
                                                                                               -, // FIXME To be set
                                                                                               {
                                                                                                 fieldName := FROM_E,
                                                                                                 addressField := p_sip.request.msgHeader.toField.addressField,
                                                                                                 fromParams := *
                                                                                               }, //p_sip.request.msgHeader.fromField,
                                                                                               {
                                                                                                 fieldName := TO_E,
                                                                                                 addressField := p_sip.request.msgHeader.fromField.addressField,
                                                                                                 toParams := *
                                                                                               } //p_sip.request.msgHeader.toField
                                                                                               )) 
                                                         },
                                                         { mw_SipRequest(mw_BYE_Request_Base) },
                                                         { 0, omit },
                                                         "TP_MX_ECSCF_ECO_BYE_02 - Request",
                                                         true,
                                                         p_checkMessage
                                                         )
                                        );
                p_monitorCompRef.done;
                // Retrieve messge
                f_getSipMsgFromMonitor(p_monitorCompRef, p_sip);
            }
        } // End of function f_mtc_check_TP_MX_ECSCF_ECO_BYE_02

    } // End of group imsBye
    
    group ims200OkBye {
        
        function f_mtc_check_TP_MX_ECSCF_ECO_200OK_BYE_01(
                                                          in SipInterfaceMonitor p_monitorCompRef,
                                                          in boolean p_checkMessage := false,
                                                          in SipMessage p_sip
                                                          ) runs on ImsTestCoordinator {
            if (isvalue(p_monitorCompRef)) {
                // Check the 200 OK BYE
                p_monitorCompRef.start(
                                       f_Iot_Sip_receive(
                                                         { mw_SipResponse(mw_ECO_200OK(
                                                                                       p_sip.request.msgHeader.cSeq,
                                                                                       p_sip.request.msgHeader.callId,
                                                                                       p_sip.request.msgHeader.fromField,
                                                                                       p_sip.request.msgHeader.toField
                                                                                       )) 
                                                         },
                                                         { mw_SipResponse(mw_200OK_Base) },
                                                         { 0, omit },
                                                         "TP_MX_ECSCF_200OK_BYE_01",
                                                         false,
                                                         p_checkMessage
                                                         )
                                        );
                p_monitorCompRef.done;
            }
        } // End of function f_mtc_check_TP_MX_ECSCF_ECO_200OK_BYE_01

    } // End of group ims200OkBye

    group imsCancel {
        
        /**
         * @desc Verify that the E-CSCF successfully processes a CANCEL from the P-CSCF for an Emergency Call under establishment and routes the request to the IBCF for a PSAP in another network
         * Initial conditions with {
         *     the IMS_E_CSCF entity supportsRoutingTo the IMS_IBCF_A and
         *     the UE_A entity hasAchievedInitialEmergencyINVITE via the IMS_IBCF_A
         * }
         * 
         * Expected behaviour
         * ensure that {
         *     when {
         *         the IMS_E_CSCF_A entity receives a CANCEL containing
         *             From indicating value PX_UE_A_SIP_URI,
         *             To indicating value PX_SIP_EMERGENCY_SERVICE_URN,
         *             CallId indicating value PX_UE_A_CALLID,
         *             Via indicating value PX_UE_A_VIA,
         *             Route indicating value PX_UE_A_SERVICE_ROUTE;
         *         from the IMS_P_CSCF_A entity
         *     }
         *     then {
         *         the IMS_E_CSCF_A entity sends a CANCEL containing
         *             From indicating value PX_UE_A_SIP_URI,
         *             To indicating value PX_SIP_EMERGENCY_SERVICE_URN,
         *             CallId indicating value PX_UE_A_CALLID,
         *             Via indicating value PX_UE_A_VIA,
         *             Route indicating value PX_UE_A_SERVICE_ROUTE;
         *         to the IM_CN entity
         *         }
         *     }
         */
        function f_mtc_check_TP_MX_ECSCF_EMC_CANCEL_01(
                                                       in SipInterfaceMonitor p_monitorCompRef,
                                                       in boolean p_checkMessage := false,
                                                       inout SipMessage p_sip
                                                       ) runs on ImsTestCoordinator {
            if (isvalue(p_monitorCompRef)) {
                // Check the CANCEL
                p_monitorCompRef.start(
                                       f_Iot_Sip_receive(
                                                         { mw_SipRequest(mw_TP_MX_ECSCF_CANCEL_01(
                                                                                                  p_sip.request.msgHeader.callId,
                                                                                                  -, // New CSeq,
                                                                                                  -, // FIXME To be set
                                                                                                  p_sip.request.msgHeader.fromField,
                                                                                                  p_sip.request.msgHeader.toField
                                                                                                  )) 
                                                         },
                                                         { mw_SipRequest(mw_CANCEL_Request_Base) },
                                                         { 0, omit },
                                                         "TP_MX_ECSCF_EMC_CANCEL_01 - Request",
                                                         true,
                                                         p_checkMessage
                                                         )
                                        );
                p_monitorCompRef.done;
                // Retrieve messge
                f_getSipMsgFromMonitor(p_monitorCompRef, p_sip);
            }
        } // End of function f_mtc_check_TP_MX_ECSCF_EMC_CANCEL_01

    } // End of group imsCancel

    group imsRequestTermination {

        /**
         * @desc Verify that the E-CSCF successfully processes a 487 response from the IBCF for a PSAP in another network for an Emergency Call and routes the response to the P-CSCF
         * Initial conditions with {
         *     the IMS_E_CSCF entity supportsRoutingTo the IMS_IBCF_A and
         *     the UE_A entity previouslyEstablishedEmergencyCallWith the PSAP via IMS_IBCF_A
         * }
         * 
         * Expected behaviour
         * ensure that {
         *     when {
         *         the IMS_E_CSCF_A entity receives a 487INVITE containing
         *             From indicating value PX_UE_A_SIP_URI,
         *             To indicating value PX_SIP_EMERGENCY_SERVICE_URN,
         *             CallId indicating value PX_UE_A_CALLID,
         *             Via indicating value PX_UE_A_VIA,
         *             Route indicating value PX_UE_A_SERVICE_ROUTE;
         *         from the IMS_IBCF_A entity
         *     }
         *     then {
         *         the IMS_E_CSCF_A entity sends a 480INVITE containing
         *             From indicating value PX_UE_A_SIP_URI,
         *             To indicating value PX_SIP_EMERGENCY_SERVICE_URN,
         *             CallId indicating value PX_UE_A_CALLID,
         *             Via indicating value PX_UE_A_VIA,
         *             Route indicating value PX_UE_A_SERVICE_ROUTE;
         *         to the IMS_P_CSCF_A entity
         *         }
         *     }
         */
        function f_mtc_check_TP_MX_ECSCF_EMC_487INVITE_01(
                                                          in SipInterfaceMonitor p_monitorCompRef,
                                                          in boolean p_checkMessage := false,
                                                          inout SipMessage p_sip
                                                          ) runs on ImsTestCoordinator {
            if (isvalue(p_monitorCompRef)) {
                // Check the 487 Request Terminated
                p_monitorCompRef.start(
                                       f_Iot_Sip_receive(
                                                         { 
                                                            mw_SipResponse(
                                                                           mw_487RequestTerminated( // TODO Enforce template
                                                                                                   p_sip.request.msgHeader.callId,
                                                                                                   -, // New CSeq
                                                                                                   p_sip.request.msgHeader.fromField,
                                                                                                   p_sip.request.msgHeader.toField,
                                                                                                   omit
                                                                                                   )
                                                                          )
                                                         },
                                                         { 
                                                             mw_SipResponse(mdw_4XX_Base)
                                                         },
                                                         { 0, omit },
                                                         "TP_MX_ECSCF_EMC_487INVITE_01",
                                                         true,
                                                         p_checkMessage
                                                         )
                                        );
                p_monitorCompRef.done;
                // Retrieve messge
                f_getSipMsgFromMonitor(p_monitorCompRef, p_sip);
            }
        } // End of function f_mtc_check_TP_MX_ECSCF_EMC_487INVITE_01
        
    } // End of group imsRequestTermination

    group imsTemporaryUnavailable {

        /**
         * @desc Verify that the E-CSCF successfully processes a 480 response from the IBCF for a PSAP in another network for an Emergency Call and routes the response to the P-CSCF
         * Initial conditions with {
         *     the IMS_E_CSCF entity supportsRoutingTo the IMS_IBCF_A and
         *     the UE_A entity previouslyEstablishedEmergencyCallWith the PSAP via IMS_IBCF_A
         * }
         * 
         * Expected behaviour
         * ensure that {
         *     when {
         *         the IMS_E_CSCF_A entity receives a 480INVITE containing
         *             From indicating value PX_UE_A_SIP_URI,
         *             To indicating value PX_SIP_EMERGENCY_SERVICE_URN,
         *             CallId indicating value PX_UE_A_CALLID,
         *             Via indicating value PX_UE_A_VIA,
         *             Route indicating value PX_UE_A_SERVICE_ROUTE;
         *         from the IMS_IBCF_A entity
         *     }
         *     then {
         *         the IMS_E_CSCF_A entity sends a 480INVITE containing
         *             From indicating value PX_UE_A_SIP_URI,
         *             To indicating value PX_SIP_EMERGENCY_SERVICE_URN,
         *             CallId indicating value PX_UE_A_CALLID,
         *             Via indicating value PX_UE_A_VIA,
         *             Route indicating value PX_UE_A_SERVICE_ROUTE;
         *         to the IMS_P_CSCF_A entity
         *         }
         *     }
         */
        function f_mtc_check_TP_MX_ECSCF_ECO_480INVITE_01(
                                                          in SipInterfaceMonitor p_monitorCompRef,
                                                          in boolean p_checkMessage := false,
                                                          inout SipMessage p_sip
                                                          ) runs on ImsTestCoordinator {
            if (isvalue(p_monitorCompRef)) {
                // Check the 487 Request Terminated
                p_monitorCompRef.start(
                                       f_Iot_Sip_receive(
                                                         { 
                                                            mw_SipResponse(mw_480TemporaryUnavailable(-, p_sip.request.msgHeader.cSeq))
                                                         },
                                                         { 
                                                             mw_SipResponse(mdw_4XX_Base)
                                                         },
                                                         { 0, omit },
                                                         "TP_MX_ECSCF_ECO_480INVITE_01",
                                                         true,
                                                         p_checkMessage
                                                         )
                                        );
                p_monitorCompRef.done;
                // Retrieve messge
                f_getSipMsgFromMonitor(p_monitorCompRef, p_sip);
            }
        } // End of function f_mtc_check_TP_MX_ECSCF_ECO_480INVITE_01
        
    } // End of group imsTemporaryUnavailable

    group ims3xxAny {

        /**
         * @desc Verify that the LRF successfully processes a 3xx Any response on initial INVITE (Originating Leg).
         * Initial conditions with {
         *     the UE_A entity isAttachedTo the EPC_A and
         *     the UE_B entity isAttachedTo the EPC_B and
         *     the UE_A entity isRegisteredTo the IMS_A and
         *     the UE_B entity isRegisteredTo the IMS_B
         * }
         * 
         * Expected behaviour
         * ensure that {
         *     when {
         *         the IMS_LRF_A entity receives an INVITE containing
         *             From indicating value PX_UE_A_SIP_URI,
         *             To indicating value PX_UE_B_SIP_URI,
         *             CallId indicating value PX_UE_A_CALLID,
         *             Via indicating value PX_UE_A_VIA,
         *             Route indicating value PX_UE_A_SERVICE_ROUTE,
         *             Contact indicating value V_CONTACT
         *             ;
         *         from the IMS_EBCF_A entity
         *     }
         *     then {
         *         the IMS_LRF_A entity sends a 3xx Any containing
         *             From indicating value PX_UE_A_SIP_URI,
         *             To indicating value PX_UE_B_SIP_URI,
         *             CallId indicating value PX_UE_A_CALLID,
         *             Via indicating value PX_UE_A_VIA,
         *             Route indicating value PX_UE_A_SERVICE_ROUTE,
         *             Contact indicating value V_CONTACT
         *             ;
         *         to the IMS_EBCF_A entity
         *         }
         *     }
         */
        function f_mtc_check_TP_MX_LRF_3xxAny_01(
                                                 in SipInterfaceMonitor p_monitorCompRef,
                                                 in boolean p_checkMessage := false,
                                                 in SipMessage p_sip
                                                 ) runs on ImsTestCoordinator {
            if (isvalue(p_monitorCompRef)) {
                // Check the 3xx Any
                p_monitorCompRef.start(
                                       f_Iot_Sip_receive(
                                                         { mw_SipResponse(mw_3xxContact(
                                                                                        p_sip.request.msgHeader.cSeq,
                                                                                        p_sip.request.msgHeader.accept
                                                                          )) 
                                                         },
                                                         { mw_SipResponse(mdw_3XX_Base) },
                                                         { 0, omit },
                                                         "TP_MX_3xxAny_01",
                                                         false,
                                                         p_checkMessage
                                                         )
                                        );
                p_monitorCompRef.done;
            }
        } // End of function f_mtc_check_TP_MX_LRF_3xxAny_01

    } // End of group ims3xxAny


    group imsINFO{  
		
		/**
		 * @desc Verify that the E-CSCF sends an INFO request demanding a transfer of updated MSD.
		 * 
		 * Reference 
		 *     "ETSI TS 124 229 [1], Clauses 5.1.6.11.3"
		 * Config Id CF_VoLTE_INT_ES
		 * PICS Selection NONE
		 * Initial conditions with {
		 *     the UE_A entity isEmergencyAttachedTo the EPC_A and
		 *     the UE_A entity isEmergencyRegisteredTo the IMS_A and
		 *     the UE_A entity isEmergencyRegisteredTo the IMS_A and
		 *     the UE_A entity previouslyEstablishedEmergencyCallWith the PSAP
		 *  }
		 * Expected behaviour
		 *     ensure that { 
                when { 
                    the IMS_P_CSCF_A entity receives a INFO containing "Request transfer of updated MSD";
                    from the IMS_E_CSCF entity
                }
                then {
                    the IMS_P_CSCF_A entity sends a INFO containing
                        From indicating value PX_PSAP_SIP_URI,
                        To indicating value PX_UE_A_SIP_URI,
                        CallId indicating value PX_PSAP_CALLID,
                        Via indicating value PX_PSAP_VIA,
                        Route indicating value PX_PSAP_SERVICE_ROUTE,
                        InfoPackage indicating value "EmergencyCallData.eCall.MSD",
                        ContentDisposition indicating value "Info-Package",
                        MessageBody containing
                           MIME indicating value "application/EmergencyCallData.Control+xml", // MIME may contain additional parts e.g., sdp, xml
                           request containing
                              action indicating value "send-data",
                              datatype indicating value "eCall.MSD";,
                           ContentDisposition indicating value "By-Reference";; 
                    to the UE_A entity
                }
            }

		 */
		function f_mtc_check_TP_MX_ECSCF_NGC_INFO_01(
													   in SipInterfaceMonitor p_monitorCompRef,
													   in boolean p_checkMessage := false,
													   out SipMessage p_sip
													   ) runs on ImsTestCoordinator {
			 if (isvalue(p_monitorCompRef)){
				var ImsUserInfo v_userInfoA := f_getSipUserId(PX_EUT_A_EMERGENCY);
				var ImsUserInfo v_psap := f_getSipUserId(PX_PSAP);
                
				// Check the INVITE
				p_monitorCompRef.start(
									   f_Iot_Sip_receive(
														{ 
															mw_SipRequest(mw_TP_MX_ECSCF_NGC_INFO_01(
																									   -, // FIXME Set expected value
																									   mw_From_AddrUnion_SipUrl(omit, v_psap.publicId, v_psap.domain),
																									   mw_To_AddrUnion_SipUrl(omit, v_userInfoA.publicId, v_userInfoA.domain),
																									   -, -,
																									   mw_PPreferredID,
																									   mw_accept({mw_acceptBody("application/EmergencyCallData.Control+xml")}),
																									   mw_recvInfo({mw_infoPackage_Type("EmergencyCallData.eCall.MSD")})
																									   ))
														},
														{ mw_SipRequest(mw_INFO_Request_Base) },
														{0, omit},
														"TP_MX_ECSCF_NGC_INFO_01 - Request",
														true,
														p_checkMessage
														)
									   );
				p_monitorCompRef.done;
				// Retrieve messge
				f_getSipMsgFromMonitor(p_monitorCompRef, p_sip);
			 }
		} // End of function f_mtc_check_TP_MX_ECSCF_NGC_INFO_01
		
		/**
		 * @desc Verify that the E-CSCF successfully receives an INFO from the UE in an established eCall type emergency call that has been requested to transfer an updated MSD.
		 * 
		 * Reference 
		 *     "ETSI TS 124 229 [1], Clauses 5.1.6.11.3"
		 * Config Id CF_VxLTE_INT
		 * PICS Selection NONE
		 * Initial conditions with {
		 *     the UE_A entity isEmergencyAttachedTo the EPC_A and
		 *     the UE_A entity isEmergencyRegisteredTo the IMS_A and
		 *     the UE_A entity previouslyEstablishedEmergencyCallWith the PSAP
		 *  }
		 * Expected behaviour
		 *     ensure that {
		 *         when {
		 *             the UE_A entity isRequestedToTransferUpdatedMSD
		 *           // UE_A has received an INFO request as described in TP_MW_PCSCF_NGC_INFO_01
		 *         }
		 *         then {
		 *           the IMS_P_CSCF_A entity receives an INFO containing
		 *               From indicating value PX_UE_A_SIP_URI,
		 *               To indicating value PX_SIP_ECALL_EMERGENCY_SERVICE_URN, // "urn:service:sos.ecall.manual" or "urn:service:sos.ecall.automatic"
		 *               CallId indicating value PX_UE_A_CALLID,
		 *               Via indicating value PX_UE_A_VIA,
		 *               Route indicating value PX_UE_A_SERVICE_ROUTE,
		 *               InfoPackage indicating value "EmergencyCallData.eCall.MSD",
		 *               ContentDisposition indicating value "Info-Package",
		 *               MessageBody containing
		 *                  MIME indicating value "application/EmergencyCallData.eCall.MSD", // MIME may contain additional parts e.g., sdp, xml
		 *                  // MSD not exceeding 140 bytes and encoded in binary ASN.1
		 *                  ContentDisposition indicating value "By-Reference";; 
		 *           from the UE_A entity
		 *       }
		 *     }
		 */
		function f_mtc_check_TP_MX_ECSCF_NGC_INFO_02(
													   in SipInterfaceMonitor p_monitorCompRef,
													   in boolean p_checkMessage := false,
													   out SipMessage p_sip
													   ) runs on ImsTestCoordinator {
			 if (isvalue(p_monitorCompRef)){
				var ImsUserInfo v_userInfoA := f_getSipUserId(PX_EUT_A_EMERGENCY);
				var ImsUserInfo v_psap := f_getSipUserId(PX_PSAP);
                
				// Check the INVITE
				p_monitorCompRef.start(
									   f_Iot_Sip_receive(
														{ 
															mw_SipRequest(mw_TP_MX_ECSCF_NGC_INFO_01(
																									   -, // FIXME Set expected value
																									   mw_From_AddrUnion_SipUrl(omit, v_userInfoA.publicId, v_userInfoA.domain),
																									   mw_To_AddrUnion_SipUrl(omit, v_psap.publicId, v_psap.domain),
																									   -,
																									   -,
																									   mw_PPreferredID,
																									   mw_accept({mw_acceptBody("application/EmergencyCallData.MSD")}),
																									   mw_recvInfo({mw_infoPackage_Type("EmergencyCallData.eCall.MSD")})
																									   ))
														},
														{ mw_SipRequest(mw_INFO_Request_Base) },
														{0, omit},
														"TP_MX_ECSCF_NGC_INFO_02 - Request",
														true,
														p_checkMessage
														)
									   );
				p_monitorCompRef.done;
				// Retrieve messge
				f_getSipMsgFromMonitor(p_monitorCompRef, p_sip);
			 }
		} // End of function f_mtc_check_TP_MX_ECSCF_NGC_INFO_02
		
	}// End of group imsINFO



} // End of module AtsImsIot_TP_behavior_MX