Commit 6cb8e398 authored by pintar's avatar pintar
Browse files

week5/2010 validation on STF368/369

parent 07ec19fd
Loading
Loading
Loading
Loading
+275 −222

File changed.

Preview size limit exceeded, changes collapsed.

+981 −891

File changed.

Preview size limit exceeded, changes collapsed.

+199 −188

File changed.

Preview size limit exceeded, changes collapsed.

+43 −43
Original line number Diff line number Diff line
@@ -192,7 +192,7 @@ module AtsNIT_SipSip_Testcases {
            		v_imsComponent2.start(f_AtsNIT_TC_SS___CN__03UE2(p_CSeq_s));
            		
            		//Synchronize both PTCs on 2 sychronization points
            		f_serverSync2ClientsAndStop({c_prDone, c_uPlane, c_tbDone});
            		f_serverSync2ClientsAndStop({c_prDone, c_sync1, c_uPlane, c_tbDone});
                    
            		f_cf_2imsDown(v_imsComponent1, v_imsComponent2);
            	} // end TC_SS___CN__03
@@ -216,7 +216,7 @@ module AtsNIT_SipSip_Testcases {
            		v_imsComponent2.start(f_AtsNIT_TC_SS___CN__04UE2(p_CSeq_s));
            		
            		//Synchronize both PTCs on 2 sychronization points
            		f_serverSync2ClientsAndStop({c_prDone, c_uPlane, c_tbDone});
            		f_serverSync2ClientsAndStop({c_prDone, c_sync1, c_uPlane, c_tbDone});
                    
            		f_cf_2imsDown(v_imsComponent1, v_imsComponent2);
            	} // end TC_SS___CN__04
@@ -358,7 +358,7 @@ module AtsNIT_SipSip_Testcases {
            		v_imsComponent2.start(f_AtsNIT_TC_SS___UP__03UE2(p_CSeq_s));
            		
            		//Synchronize both PTCs on 2 sychronization points
            		f_serverSync2ClientsAndStop({c_prDone, c_uPlane, c_tbDone});
            		f_serverSync2ClientsAndStop({c_prDone, c_sync1, c_uPlane, c_tbDone});
                    
            		f_cf_2imsDown(v_imsComponent1, v_imsComponent2);
            	} // end TC_SS___UP__03
@@ -381,7 +381,7 @@ module AtsNIT_SipSip_Testcases {
            		v_imsComponent2.start(f_AtsNIT_TC_SS___UP__04UE2(p_CSeq_s));
            		
            		//Synchronize both PTCs on 2 sychronization points
            		f_serverSync2ClientsAndStop({c_prDone, c_uPlane, c_tbDone});
            		f_serverSync2ClientsAndStop({c_prDone, c_sync1, c_uPlane, c_tbDone});
                    
            		f_cf_2imsDown(v_imsComponent1, v_imsComponent2);
            	} // end TC_SS___UP__04
@@ -427,7 +427,7 @@ module AtsNIT_SipSip_Testcases {
            		v_imsComponent2.start(f_AtsNIT_TC_SS___UP__06UE2(p_CSeq_s));
            		
            		//Synchronize both PTCs on 2 sychronization points
            		f_serverSync2ClientsAndStop({c_prDone, c_uPlane, c_tbDone});
            		f_serverSync2ClientsAndStop({c_prDone, c_sync1, c_uPlane, c_tbDone});
                    
            		f_cf_2imsDown(v_imsComponent1, v_imsComponent2);
            	} // end TC_SS___UP__06
@@ -473,7 +473,7 @@ module AtsNIT_SipSip_Testcases {
            		v_imsComponent2.start(f_AtsNIT_TC_SS___UP__08UE2(p_CSeq_s));
            		
            		//Synchronize both PTCs on 2 sychronization points
            		f_serverSync2ClientsAndStop({c_prDone, c_uPlane, c_tbDone});
            		f_serverSync2ClientsAndStop({c_prDone, c_sync1, c_uPlane, c_tbDone});
                    
            		f_cf_2imsDown(v_imsComponent1, v_imsComponent2);
            	} // end TC_SS___UP__08
@@ -1705,7 +1705,7 @@ group TP_2_SupplementaryServices {
    		v_imsComponent2.start(f_AtsNIT_TC_SS___XXSSCH01UE2(p_CSeq_s));
    		
    		//Synchronize both PTCs on following sychronization points
    		f_serverSync2ClientsAndStop({c_prDone, c_tbDone});
    		f_serverSync2ClientsAndStop({c_prDone, c_sync1, c_tbDone});
            
            //Clear configuration
    		f_cf_2imsDown(v_imsComponent1, v_imsComponent2);
@@ -1732,7 +1732,7 @@ group TP_2_SupplementaryServices {
    		v_imsComponent2.start(f_AtsNIT_TC_SS___XXSSCH02UE2(p_CSeq_s));
    		
    		//Synchronize both PTCs on following sychronization points
    		f_serverSync2ClientsAndStop({c_prDone, c_tbDone});
    		f_serverSync2ClientsAndStop({c_prDone, c_sync1, c_sync2, c_tbDone});
            
            //Clear configuration
    		f_cf_2imsDown(v_imsComponent1, v_imsComponent2);
@@ -1759,7 +1759,7 @@ group TP_2_SupplementaryServices {
    		v_imsComponent2.start(f_AtsNIT_TC_SS___XXSSCH03UE2(p_CSeq_s));
    		
    		//Synchronize both PTCs on following sychronization points
    		f_serverSync2ClientsAndStop({c_prDone, c_tbDone});
    		f_serverSync2ClientsAndStop({c_prDone, c_sync1, c_sync2, c_tbDone});
            
            //Clear configuration
    		f_cf_2imsDown(v_imsComponent1, v_imsComponent2);
@@ -1786,7 +1786,7 @@ group TP_2_SupplementaryServices {
    		v_imsComponent2.start(f_AtsNIT_TC_SS___XXSSCH04UE2(p_CSeq_s));
    		
    		//Synchronize both PTCs on following sychronization points
    		f_serverSync2ClientsAndStop({c_prDone, c_tbDone});
    		f_serverSync2ClientsAndStop({c_prDone, c_sync1, c_sync2, c_sync3, c_tbDone});
            
            //Clear configuration
    		f_cf_2imsDown(v_imsComponent1, v_imsComponent2);
@@ -1813,7 +1813,7 @@ group TP_2_SupplementaryServices {
    		v_imsComponent2.start(f_AtsNIT_TC_SS___XXSSCH05UE2(p_CSeq_s));
    		
    		//Synchronize both PTCs on following sychronization points
    		f_serverSync2ClientsAndStop({c_prDone, c_tbDone});
    		f_serverSync2ClientsAndStop({c_prDone, c_sync1, c_tbDone});
            
            //Clear configuration
    		f_cf_2imsDown(v_imsComponent1, v_imsComponent2);
@@ -1840,7 +1840,7 @@ group TP_2_SupplementaryServices {
    		v_imsComponent2.start(f_AtsNIT_TC_SS___XXSSCH06UE2(p_CSeq_s));
    		
    		//Synchronize both PTCs on following sychronization points
    		f_serverSync2ClientsAndStop({c_prDone, c_tbDone});
    		f_serverSync2ClientsAndStop({c_prDone, c_sync1, c_sync2, c_tbDone});
            
            //Clear configuration
    		f_cf_2imsDown(v_imsComponent1, v_imsComponent2);
@@ -1867,7 +1867,7 @@ group TP_2_SupplementaryServices {
    		v_imsComponent2.start(f_AtsNIT_TC_SS___XXSSCH07UE2(p_CSeq_s));
    		
    		//Synchronize both PTCs on following sychronization points
    		f_serverSync2ClientsAndStop({c_prDone, c_tbDone});
    		f_serverSync2ClientsAndStop({c_prDone, c_sync1, c_sync2, c_tbDone});
            
            //Clear configuration
    		f_cf_2imsDown(v_imsComponent1, v_imsComponent2);
@@ -1894,7 +1894,7 @@ group TP_2_SupplementaryServices {
    		v_imsComponent2.start(f_AtsNIT_TC_SS___XXSSCH08UE2(p_CSeq_s));
    		
    		//Synchronize both PTCs on following sychronization points
    		f_serverSync2ClientsAndStop({c_prDone, c_tbDone});
    		f_serverSync2ClientsAndStop({c_prDone, c_sync1, c_sync2, c_sync3, c_tbDone});
            
            //Clear configuration
    		f_cf_2imsDown(v_imsComponent1, v_imsComponent2);
@@ -1921,7 +1921,7 @@ group TP_2_SupplementaryServices {
    		v_imsComponent2.start(f_AtsNIT_TC_SS___XXSSCH09UE2(p_CSeq_s));
    		
    		//Synchronize both PTCs on following sychronization points
    		f_serverSync2ClientsAndStop({c_prDone, c_tbDone});
    		f_serverSync2ClientsAndStop({c_prDone, c_sync1, c_tbDone});
            
            //Clear configuration
    		f_cf_2imsDown(v_imsComponent1, v_imsComponent2);
@@ -1948,7 +1948,7 @@ group TP_2_SupplementaryServices {
    		v_imsComponent2.start(f_AtsNIT_TC_SS___XXSSCH10UE2(p_CSeq_s));
    		
    		//Synchronize both PTCs on following sychronization points
    		f_serverSync2ClientsAndStop({c_prDone, c_tbDone});
    		f_serverSync2ClientsAndStop({c_prDone, c_sync1, c_sync2, c_tbDone});
            
            //Clear configuration
    		f_cf_2imsDown(v_imsComponent1, v_imsComponent2);
@@ -1975,7 +1975,7 @@ group TP_2_SupplementaryServices {
    		v_imsComponent2.start(f_AtsNIT_TC_SS___XXSSCH11UE2(p_CSeq_s));
    		
    		//Synchronize both PTCs on following sychronization points
    		f_serverSync2ClientsAndStop({c_prDone, c_tbDone});
    		f_serverSync2ClientsAndStop({c_prDone, c_sync1, c_sync2, c_tbDone});
            
            //Clear configuration
    		f_cf_2imsDown(v_imsComponent1, v_imsComponent2);
@@ -2002,7 +2002,7 @@ group TP_2_SupplementaryServices {
    		v_imsComponent2.start(f_AtsNIT_TC_SS___XXSSCH12UE2(p_CSeq_s));
    		
    		//Synchronize both PTCs on following sychronization points
    		f_serverSync2ClientsAndStop({c_prDone, c_tbDone});
    		f_serverSync2ClientsAndStop({c_prDone, c_sync1, c_sync2, c_sync3, c_tbDone});
            
            //Clear configuration
    		f_cf_2imsDown(v_imsComponent1, v_imsComponent2);
@@ -2029,7 +2029,7 @@ group TP_2_SupplementaryServices {
    		v_imsComponent2.start(f_AtsNIT_TC_SS___XXSSCH13UE2(p_CSeq_s));
    		
    		//Synchronize both PTCs on following sychronization points
    		f_serverSync2ClientsAndStop({c_prDone, c_tbDone});
    		f_serverSync2ClientsAndStop({c_prDone, c_sync1, c_tbDone});
            
            //Clear configuration
    		f_cf_2imsDown(v_imsComponent1, v_imsComponent2);
@@ -2056,7 +2056,7 @@ group TP_2_SupplementaryServices {
    		v_imsComponent2.start(f_AtsNIT_TC_SS___XXSSCH14UE2(p_CSeq_s));
    		
    		//Synchronize both PTCs on following sychronization points
    		f_serverSync2ClientsAndStop({c_prDone, c_tbDone});
    		f_serverSync2ClientsAndStop({c_prDone, c_sync1, c_sync2, c_tbDone});
            
            //Clear configuration
    		f_cf_2imsDown(v_imsComponent1, v_imsComponent2);
@@ -2083,7 +2083,7 @@ group TP_2_SupplementaryServices {
    		v_imsComponent2.start(f_AtsNIT_TC_SS___XXSSCH15UE2(p_CSeq_s));
    		
    		//Synchronize both PTCs on following sychronization points
    		f_serverSync2ClientsAndStop({c_prDone, c_tbDone});
    		f_serverSync2ClientsAndStop({c_prDone, c_sync1, c_sync2, c_tbDone});
            
            //Clear configuration
    		f_cf_2imsDown(v_imsComponent1, v_imsComponent2);
@@ -2110,7 +2110,7 @@ group TP_2_SupplementaryServices {
    		v_imsComponent2.start(f_AtsNIT_TC_SS___XXSSCH16UE2(p_CSeq_s));
    		
    		//Synchronize both PTCs on following sychronization points
    		f_serverSync2ClientsAndStop({c_prDone, c_tbDone});
    		f_serverSync2ClientsAndStop({c_prDone, c_sync1, c_sync2, c_sync3, c_tbDone});
            
            //Clear configuration
    		f_cf_2imsDown(v_imsComponent1, v_imsComponent2);
@@ -2137,7 +2137,7 @@ group TP_2_SupplementaryServices {
    		v_imsComponent2.start(f_AtsNIT_TC_SS___XXSSCH17UE2(p_CSeq_s));
    		
    		//Synchronize both PTCs on following sychronization points
    		f_serverSync2ClientsAndStop({c_prDone, c_tbDone});
    		f_serverSync2ClientsAndStop({c_prDone, c_sync1, c_uPlane, c_annoucB, c_tbDone});
            
            //Clear configuration
    		f_cf_2imsDown(v_imsComponent1, v_imsComponent2);
@@ -2164,7 +2164,7 @@ group TP_2_SupplementaryServices {
    		v_imsComponent2.start(f_AtsNIT_TC_SS___XXSSCH18UE2(p_CSeq_s));
    		
    		//Synchronize both PTCs on following sychronization points
    		f_serverSync2ClientsAndStop({c_prDone, c_tbDone});
    		f_serverSync2ClientsAndStop({c_prDone, c_sync1, c_uPlane, c_annoucA, c_uPlaneStop, c_tbDone});
            
            //Clear configuration
    		f_cf_2imsDown(v_imsComponent1, v_imsComponent2);
@@ -2191,7 +2191,7 @@ group TP_2_SupplementaryServices {
    		v_imsComponent2.start(f_AtsNIT_TC_SS___XXSSCH19UE2(p_CSeq_s));
    		
    		//Synchronize both PTCs on following sychronization points
    		f_serverSync2ClientsAndStop({c_prDone, c_tbDone});
    		f_serverSync2ClientsAndStop({c_prDone, c_sync1, c_uPlane, c_annoucB, c_uPlane, c_tbDone});
            
            //Clear configuration
    		f_cf_2imsDown(v_imsComponent1, v_imsComponent2);
@@ -2218,7 +2218,7 @@ group TP_2_SupplementaryServices {
    		v_imsComponent2.start(f_AtsNIT_TC_SS___XXSSCH20UE2(p_CSeq_s));
    		
    		//Synchronize both PTCs on following sychronization points
    		f_serverSync2ClientsAndStop({c_prDone, c_tbDone});
    		f_serverSync2ClientsAndStop({c_prDone, c_sync1, c_uPlane, c_annoucA, c_uPlaneStop, c_annoucA, c_tbDone});
            
            //Clear configuration
    		f_cf_2imsDown(v_imsComponent1, v_imsComponent2);
@@ -2245,7 +2245,7 @@ group TP_2_SupplementaryServices {
    		v_imsComponent2.start(f_AtsNIT_TC_SS___XXSSCH21UE2(p_CSeq_s));
    		
    		//Synchronize both PTCs on following sychronization points
    		f_serverSync2ClientsAndStop({c_prDone, c_tbDone});
    		f_serverSync2ClientsAndStop({c_prDone, c_sync1, c_uPlane, c_annoucA, c_tbDone});
            
            //Clear configuration
    		f_cf_2imsDown(v_imsComponent1, v_imsComponent2);
@@ -2272,7 +2272,7 @@ group TP_2_SupplementaryServices {
    		v_imsComponent2.start(f_AtsNIT_TC_SS___XXSSCH22UE2(p_CSeq_s));
    		
    		//Synchronize both PTCs on following sychronization points
    		f_serverSync2ClientsAndStop({c_prDone, c_tbDone});
    		f_serverSync2ClientsAndStop({c_prDone, c_sync1, c_uPlane, c_annoucB, c_uPlaneStop, c_tbDone});
            
            //Clear configuration
    		f_cf_2imsDown(v_imsComponent1, v_imsComponent2);
@@ -2299,7 +2299,7 @@ group TP_2_SupplementaryServices {
    		v_imsComponent2.start(f_AtsNIT_TC_SS___XXSSCH23UE2(p_CSeq_s));
    		
    		//Synchronize both PTCs on following sychronization points
    		f_serverSync2ClientsAndStop({c_prDone, c_tbDone});
    		f_serverSync2ClientsAndStop({c_prDone, c_sync1, c_uPlane, c_annoucA, c_uPlane, c_tbDone});
            
            //Clear configuration
    		f_cf_2imsDown(v_imsComponent1, v_imsComponent2);
@@ -2326,7 +2326,7 @@ group TP_2_SupplementaryServices {
    		v_imsComponent2.start(f_AtsNIT_TC_SS___XXSSCH24UE2(p_CSeq_s));
    		
    		//Synchronize both PTCs on following sychronization points
    		f_serverSync2ClientsAndStop({c_prDone, c_tbDone});
    		f_serverSync2ClientsAndStop({c_prDone, c_sync1, c_uPlane, c_annoucB, c_uPlaneStop, c_annoucB, c_tbDone});
            
            //Clear configuration
    		f_cf_2imsDown(v_imsComponent1, v_imsComponent2);
@@ -2353,7 +2353,7 @@ group TP_2_SupplementaryServices {
    		v_imsComponent2.start(f_AtsNIT_TC_SS___XXSSCH25UE2(p_CSeq_s));
    		
    		//Synchronize both PTCs on following sychronization points
    		f_serverSync2ClientsAndStop({c_prDone, c_tbDone});
    		f_serverSync2ClientsAndStop({c_prDone, c_sync1, c_uPlane, c_annoucB, c_tbDone});
            
            //Clear configuration
    		f_cf_2imsDown(v_imsComponent1, v_imsComponent2);
@@ -2380,7 +2380,7 @@ group TP_2_SupplementaryServices {
    		v_imsComponent2.start(f_AtsNIT_TC_SS___XXSSCH26UE2(p_CSeq_s));
    		
    		//Synchronize both PTCs on following sychronization points
    		f_serverSync2ClientsAndStop({c_prDone, c_tbDone});
    		f_serverSync2ClientsAndStop({c_prDone, c_sync1, c_uPlane, c_annoucA, c_uPlaneStop, c_tbDone});
            
            //Clear configuration
    		f_cf_2imsDown(v_imsComponent1, v_imsComponent2);
@@ -2407,7 +2407,7 @@ group TP_2_SupplementaryServices {
    		v_imsComponent2.start(f_AtsNIT_TC_SS___XXSSCH27UE2(p_CSeq_s));
    		
    		//Synchronize both PTCs on following sychronization points
    		f_serverSync2ClientsAndStop({c_prDone, c_tbDone});
    		f_serverSync2ClientsAndStop({c_prDone, c_sync1, c_uPlane, c_annoucB, c_uPlane, c_tbDone});
            
            //Clear configuration
    		f_cf_2imsDown(v_imsComponent1, v_imsComponent2);
@@ -2434,7 +2434,7 @@ group TP_2_SupplementaryServices {
    		v_imsComponent2.start(f_AtsNIT_TC_SS___XXSSCH28UE2(p_CSeq_s));
    		
    		//Synchronize both PTCs on following sychronization points
    		f_serverSync2ClientsAndStop({c_prDone, c_tbDone});
    		f_serverSync2ClientsAndStop({c_prDone, c_sync1, c_uPlane, c_annoucA, c_uPlaneStop, c_annoucA, c_tbDone});
            
            //Clear configuration
    		f_cf_2imsDown(v_imsComponent1, v_imsComponent2);
@@ -2461,7 +2461,7 @@ group TP_2_SupplementaryServices {
    		v_imsComponent2.start(f_AtsNIT_TC_SS___XXSSCH29UE2(p_CSeq_s));
    		
    		//Synchronize both PTCs on following sychronization points
    		f_serverSync2ClientsAndStop({c_prDone, c_tbDone});
    		f_serverSync2ClientsAndStop({c_prDone, c_sync1, c_uPlane, c_annoucA, c_tbDone});
            
            //Clear configuration
    		f_cf_2imsDown(v_imsComponent1, v_imsComponent2);
@@ -2488,7 +2488,7 @@ group TP_2_SupplementaryServices {
    		v_imsComponent2.start(f_AtsNIT_TC_SS___XXSSCH30UE2(p_CSeq_s));
    		
    		//Synchronize both PTCs on following sychronization points
    		f_serverSync2ClientsAndStop({c_prDone, c_tbDone});
    		f_serverSync2ClientsAndStop({c_prDone, c_sync1, c_uPlane, c_annoucB, c_uPlaneStop, c_tbDone});
            
            //Clear configuration
    		f_cf_2imsDown(v_imsComponent1, v_imsComponent2);
@@ -2515,7 +2515,7 @@ group TP_2_SupplementaryServices {
    		v_imsComponent2.start(f_AtsNIT_TC_SS___XXSSCH31UE2(p_CSeq_s));
    		
    		//Synchronize both PTCs on following sychronization points
    		f_serverSync2ClientsAndStop({c_prDone, c_tbDone});
    		f_serverSync2ClientsAndStop({c_prDone, c_sync1, c_uPlane, c_annoucA, c_uPlane, c_tbDone});
            
            //Clear configuration
    		f_cf_2imsDown(v_imsComponent1, v_imsComponent2);
@@ -2542,7 +2542,7 @@ group TP_2_SupplementaryServices {
    		v_imsComponent2.start(f_AtsNIT_TC_SS___XXSSCH32UE2(p_CSeq_s));
    		
    		//Synchronize both PTCs on following sychronization points
    		f_serverSync2ClientsAndStop({c_prDone, c_tbDone});
    		f_serverSync2ClientsAndStop({c_prDone, c_sync1, c_uPlane, c_annoucB, c_uPlaneStop, c_annoucB, c_tbDone});
            
            //Clear configuration
    		f_cf_2imsDown(v_imsComponent1, v_imsComponent2);
@@ -4502,7 +4502,7 @@ group TP_2_SupplementaryServices {
        
        		//Start
        		v_imsComponent1.start(f_AtsNIT_TC_SS___XXSSCW_01UE1(p_CSeq_s));
        		v_imsComponent2.start(f_AtsNIT_TC_SS___XXSSCW_01UE1(p_CSeq_s));
        		v_imsComponent2.start(f_AtsNIT_TC_SS___XXSSCW_01UE2(p_CSeq_s));
        		
        		//Synchronize both PTCs on 3 sychronization points
        		f_serverSync2ClientsAndStop({c_initDone, c_prDone, c_tbDone});
@@ -4528,7 +4528,7 @@ group TP_2_SupplementaryServices {
        
        		//Start
        		v_imsComponent1.start(f_AtsNIT_TC_SS___XXSSCW_02UE1(p_CSeq_s));
        		v_imsComponent2.start(f_AtsNIT_TC_SS___XXSSCW_02UE1(p_CSeq_s));
        		v_imsComponent2.start(f_AtsNIT_TC_SS___XXSSCW_02UE2(p_CSeq_s));
        		
        		//Synchronize both PTCs on 3 sychronization points
        		f_serverSync2ClientsAndStop({c_initDone, c_prDone, c_tbDone});
@@ -4554,7 +4554,7 @@ group TP_2_SupplementaryServices {
        
        		//Start
        		v_imsComponent1.start(f_AtsNIT_TC_SS___XXSSCW_03UE1(p_CSeq_s));
        		v_imsComponent2.start(f_AtsNIT_TC_SS___XXSSCW_03UE1(p_CSeq_s));
        		v_imsComponent2.start(f_AtsNIT_TC_SS___XXSSCW_03UE2(p_CSeq_s));
        		
        		//Synchronize both PTCs on 3 sychronization points
        		f_serverSync2ClientsAndStop({c_prDone, c_tbDone, c_poDone});
@@ -4580,7 +4580,7 @@ group TP_2_SupplementaryServices {
        
        		//Start
        		v_imsComponent1.start(f_AtsNIT_TC_SS___XXSSCW_04UE1(p_CSeq_s));
        		v_imsComponent2.start(f_AtsNIT_TC_SS___XXSSCW_04UE1(p_CSeq_s));
        		v_imsComponent2.start(f_AtsNIT_TC_SS___XXSSCW_04UE2(p_CSeq_s));
        		
        		//Synchronize both PTCs on 6 sychronization points
        		f_serverSync2ClientsAndStop({c_initDone, c_prDone, c_sync1, c_sync2, c_sync3, c_tbDone});
@@ -4606,7 +4606,7 @@ group TP_2_SupplementaryServices {
        
        		//Start
        		v_imsComponent1.start(f_AtsNIT_TC_SS___XXSSCW_05UE1(p_CSeq_s));
        		v_imsComponent2.start(f_AtsNIT_TC_SS___XXSSCW_05UE1(p_CSeq_s));
        		v_imsComponent2.start(f_AtsNIT_TC_SS___XXSSCW_05UE2(p_CSeq_s));
        		
        		//Synchronize both PTCs on 5 sychronization points
        		f_serverSync2ClientsAndStop({c_prDone, c_sync1, c_sync2, c_sync3, c_tbDone});