 *    @author   ETSI / STF484
 *    @version  $URL: file:///D:/RepositoriesNew/ITS/branches/STF484_VALIDATION/ttcn/AtsDENM/ItsDenm_TestCases.ttcn $
 *              $Id: ItsDenm_TestCases.ttcn 2204 2015-04-28 08:54:07Z berge $
 *    @desc     DENM Testcases (TS 102 869-2 V<2.1.1> (<2012-09>))
 *
 */

module ItsDenm_TestCases {
   
    // ATS ITS
    import from ItsDenm_TpFunctions all;
   
        // LibIts
    import from LibItsDenm_TestSystem all;
   
    // 5.2.1
    group denMessageTransmission {
       
      // 5.2.1.1
      group denMessageFormat {
         
          /**
           * @desc    Check that protocolVersion is set to 1 and messageID is set to 1
           * <pre>        
           * PICS Selection: none
           * Initial conditions:
           *  with {
           *      the IUT being in the "initial state"
           *  }
           * Expected behaviour:
           *  ensure that {
           *      when {
           *          the IUT receives an AppDENM_Trigger request from the application layer
           *      }
           *      then {
           *          the IUT sends a valid DENM
           *              containing ITS PDU header,
           *                  containing protocolVersion
           *                      indicating value 1
           *                  and containing messageID
           *                      indicating value 1
           *      }
           *  }
           * </pre>
           *
           * @see     ETSI TS 102 869-2 v1.4.1 TP/DEN/MSGF/BV-01, ETSI EN 302 637-3, Annex B.1
           */

          testcase TC_DEN_MSGF_BV_01() runs on ItsDenm system ItsDenmSystem {
             
              f_DEN_MSGF_BV_01();
             
          } // end TC_DEN_MSGF_BV_01
         
          /**
           * @desc    Check that sent DENM contains at least one 'trace' DE
           * <pre>        
           * PICS Selection: none
           * Initial conditions:
           *  with {
           *      the IUT being in the "initial state"
           *  }
           * Expected behaviour:
           *  ensure that {
           *      when {
           *          the IUT receives an AppDENM_Trigger request from the application layer
           *      }
           *      then {
           *          the IUT sends a valid DENM
           *              containing location container
           *                  containing at least one 'trace'
           *      }
           *  }
           * </pre>
           *
           * @see     ETSI TS 102 869-2 v1.4.1 TP/DEN/MSGF/BV-02, ETSI EN 302 637-3, clause  6.1.3.2
           */

          testcase TC_DEN_MSGF_BV_02() runs on ItsDenm system ItsDenmSystem {
             
              f_DEN_MSGF_BV_02();
             
          } // end TC_DEN_MSGF_BV_02
         
      } // end denMessageFormat
     
      // 5.2.1.2
      group denEventGeneration {
       
          /**
           * @desc    Check that DEN Basic Service generates a new DENM on reception of a valid AppDENM_Trigger request
           * <pre>        
           * PICS Selection: none
           * Initial conditions:
           *  with {
           *      the IUT being in the "initial state"
           *  }
           * Expected behaviour:
           *  ensure that {
           *      when {
           *          the IUT receives an AppDENM_Trigger request from the application layer
           *      }
           *      then {
           *          the IUT sends a valid DENM
           *      }
           *  }
           * </pre>
           *
           * @see     ETSI TS 102 869-2 v1.4.1 TP/DEN/EVGN/BV-01, ETSI EN 302 637-3, clause 6.1.2.1
           */

          testcase TC_DEN_EVGN_BV_01() runs on ItsDenm system ItsDenmSystem {
             
              f_DEN_EVGN_BV_01();
             
          } // end TC_DEN_EVGN_BV_01
         
          /**
           * @desc    Check that a new ActionID value is assigned for each newly generated DENM
           * <pre>        
           * PICS Selection: none
           * Initial conditions:
           *  with {
           *      the IUT being in the "initial state"
           *      and the IUT having generated several events
           *  }
           * Expected behaviour:
           *  ensure that {
           *      when {
           *          the IUT is requested to generate a new event
           *      }
           *      then {
           *          the IUT sends a valid DENM
           *              containing management container
           *                  containing actionID
           *                      indicating an unused value
           *      }
           *  }
           * </pre>
           *
           * @see     ETSI TS 102 869-2 v1.4.1 TP/DEN/EVGN/BV-02, ETSI EN 302 637-3, clause 6.1.1.1
           */

          testcase TC_DEN_EVGN_BV_02() runs on ItsDenm system ItsDenmSystem {
             
              f_DEN_EVGN_BV_02();
             
          } // end TC_DEN_EVGN_BV_02
         
          /**
           * @desc    Check that a newly created ActionID contains the StationID of the originating ITS-S that detected the event
           * <pre>        
           * PICS Selection: none
           * Initial conditions:
           *  with {
           *      the IUT being in the "initial state"
           *  }
           * Expected behaviour:
           *  ensure that {
           *      when {
           *          the IUT is requested to generate a new event
           *      }
           *      then {
           *          the IUT sends a valid DENM
           *              containing management container
           *                  containing actionID
           *                      containing originatingStationID
           *                          indicating its own StationID
           *      }
           *  }
           * </pre>
           *
           * @see     ETSI TS 102 869-2 v1.4.1 TP/DEN/EVGN/BV-03, ETSI EN 302 637-3, clause 6.1.1.1
           */

          testcase TC_DEN_EVGN_BV_03() runs on ItsDenm system ItsDenmSystem {
             
              f_DEN_EVGN_BV_03();
             
          } // end TC_DEN_EVGN_BV_03
         
          /**
           * @desc    Check that Cause and subcause values included in DENM as provided by application
           * <pre>        
           * PICS Selection: none
           * Initial conditions:
           *  with {
           *      the IUT being in the "initial state"
           *  }
           * Expected behaviour:
           *  ensure that {
           *      when {
           *          the IUT receives an AppDENM_trigger request from the application layer
           *              containing situation container
           *                  containing eventType
           *                      containing causeCode
           *                          indicating Value1
           *                      containing subCauseCode
           *                          indicating Value2
           *      }
           *      then {
           *          the IUT sends a valid DENM
           *              containing situation container
           *                  containing eventType
           *                      containing causeCode
           *                          indicating Value1
           *                      containing subCauseCode
           *                          indicating Value2
           *      }
           *  }
           * </pre>
           *
           * @see     ETSI TS 102 869-2 v1.4.1 TP/DEN/EVGN/BV-04, ETSI EN 302 637-3, clause 7.1.3
           */

          testcase TC_DEN_EVGN_BV_04() runs on ItsDenm system ItsDenmSystem {
             
              f_DEN_EVGN_BV_04();
             
          } // end TC_DEN_EVGN_BV_04
         
          /**
           * @desc    Check that referenceTime is set to the current time when generating a DENM for a new event
           * <pre>        
           * PICS Selection: none
           * Initial conditions:
           *  with {
           *      the IUT being in the "initial state"
           *      and the IUT having generated several events
           *  }
           * Expected behaviour:
           *  ensure that {
           *      when {
           *          the IUT is requested to generate a new event
           *      }
           *      then {
           *          the IUT sends a valid DENM
           *              containing management container
           *                  containing referenceTime
           *                      indicating CLT
           *      }
           *  }
           * </pre>
           *
           * @see     ETSI TS 102 869-2 v1.4.1 TP/DEN/EVGN/BV-05, ETSI EN 302 637-3, clause 8.2.1.3
           */

          testcase TC_DEN_EVGN_BV_05() runs on ItsDenm system ItsDenmSystem {
             
              f_DEN_EVGN_BV_05();
             
          } // end TC_DEN_EVGN_BV_05
         
          /**
           * @desc    Check that sequenceNumber is set to a next unused value each time an event is detected
           * <pre>        
           * PICS Selection: none
           * Initial conditions:
           *  with {
           *      the IUT being in the "initial state"
           *      and the IUT having generated several events
           *      and the IUT having generated its last DENM
           *          containing management container
           *              containing actionID
           *                  containing sequenceNumber
           *                      indicating SEQ1
           *      and no active event being associated with sequenceNumber SEQ1 + 1
           *  }
           * Expected behaviour:
           *  ensure that {
           *      when {
           *          the IUT is requested to generate a new event
           *      }
           *      then {
           *          the IUT sends a valid DENM
           *              containing management container
           *                  containing actionID
           *                      containing sequenceNumber
           *                          indicating SEQ1 + 1
           *      }
           *  }
           * </pre>
           *
           * @see     ETSI TS 102 869-2 v1.4.1 TP/DEN/EVGN/BV-07, ETSI EN 302 637-3, clauses 6.1.1.1, 8.2.1.2
           */

          testcase TC_DEN_EVGN_BV_07() runs on ItsDenm system ItsDenmSystem {
             
              f_DEN_EVGN_BV_07();
             
          } // end TC_DEN_EVGN_BV_07
         
          /**
           * @desc    Check that sequenceNumber is set to a next unused value each time an event is detected (Sequence number wrap around)
           * <pre>        
           * PICS Selection: none
           * Initial conditions:
           *  with {
           *      the IUT being in the "initial state"
           *      and the IUT having generated several events
           *      and the IUT having generated its last DENM
           *          containing management container
           *              containing actionID
           *                  containing sequenceNumber
           *                      indicating SEQ1
           *      and an active event being associated with sequenceNumber SEQ1 + 1
           *      and no active event being associated with sequenceNumber SEQ1 + 2
           *  }
           * Expected behaviour:
           *  ensure that {
           *      when {
           *          the IUT is requested to generate a new event
           *      }
           *      then {
           *          the IUT sends a valid DENM
           *              containing management container
           *                  containing actionID
           *                      containing sequenceNumber
           *                          indicating SEQ1 + 2
           *      }
           *  }
           * </pre>
           *
           * @see     ETSI TS 102 869-2 v1.4.1 TP/DEN/EVGN/BV-08, ETSI EN 302 637-3, clauses 6.1.1.1, 8.2.1.2
           */

          testcase TC_DEN_EVGN_BV_08() runs on ItsDenm system ItsDenmSystem {
             
              f_DEN_EVGN_BV_08();
             
          } // end TC_DEN_EVGN_BV_08
         
          /**
           * @desc    Check that actionID are generated using newly assigned stationID when a pseudonym change occurs
           * <pre>        
           * PICS Selection: none
           * Initial conditions:
           *  with {
           *      the IUT being in the "initial state"
           *      and the IUT having generated several events
           *          containing management container
           *              containing actionID
           *                  containing originatingStationID
           *                      indicating STATION_ID_1
           *      and the IUT having changed its StationID
           *  }
           * Expected behaviour:
           *  ensure that {
           *      when {
           *          the IUT is requested to generate a new event
           *      }
           *      then {
           *          the IUT sends a valid DENM
           *              containing management container
           *                  containing actionID
           *                      containing originatingStationID
           *                          indicating its new StationID
           *      }
           *  }
           * </pre>
           *
           * @see     ETSI TS 102 869-2 v1.4.1 TP/DEN/EVGN/BV-10, ETSI EN 302 637-3, clauses 6.1.1.2
           */

          testcase TC_DEN_EVGN_BV_10() runs on ItsDenm system ItsDenmSystem {
             
              f_DEN_EVGN_BV_10();
             
          } // end TC_DEN_EVGN_BV_10
         
      } // end denEventGeneration
     
      // 5.2.1.3
      group denEventUpdate {
         
          /**
           * @desc    Check that DEN Basic Service generates an update DENM on reception of a valid AppDENM_update request
           * <pre>        
           * PICS Selection: none
           * Initial conditions:
           *  with {
           *      the IUT being in the "initial state"
           *      and the IUT having generated an event
           *  }
           * Expected behaviour:
           *  ensure that {
           *      when {
           *          the IUT receives an AppDENM_update request from the application layer
           *      }
           *      then {
           *          the IUT sends a valid DENM
           *      }
           *  }
           * </pre>
           *
           * @see     ETSI TS 102 869-2 v1.4.1 TP/DEN/EVUP/BV-01, ETSI EN 302 637-3, clause 6.1.2.2
           */

          testcase TC_DEN_EVUP_BV_01() runs on ItsDenm system ItsDenmSystem {
             
              f_DEN_EVUP_BV_01();
             
          } // end TC_DEN_EVUP_BV_01
         
          /**
           * @desc    Check that the actionID is not changed by DENM update, as long as the stationID of the originating ITS-S remains unchanged
           * <pre>        
           * PICS Selection: none
           * Initial conditions:
           *  with {
           *      the IUT being in the "initial state"
           *      and the IUT having generated an event
           *          containing management container
           *              containing actionID
           *                  indicating ACTION_ID1
           *      and the IUT not having changed its stationID
           *  }
           * Expected behaviour:
           *  ensure that {
           *      when {
           *          the IUT receives an AppDENM_update request associated with ACTION_ID1 from the application layer
           *      }
           *      then {
           *          the IUT sends a valid DENM
           *              containing management container
           *                  containing actionID
           *                      indicating ACTION_ID1
           *      }
           *  }
           * </pre>
           *
           * @see     ETSI TS 102 869-2 v1.4.1 TP/DEN/EVUP/BV-02, ETSI EN 302 637-3, clauses 6.1.2.2, 8.1.1.1
           */

          testcase TC_DEN_EVUP_BV_02() runs on ItsDenm system ItsDenmSystem {
             
              f_DEN_EVUP_BV_02();
             
          } // end TC_DEN_EVUP_BV_02
         
          /**
           * @desc    Check that referenceTime is set to the current time when generating a DENM for an updated eventCheck
           * <pre>        
           * PICS Selection: none
           * Initial conditions:
           *  with {
           *      the IUT being in the "initial state"
           *      and the IUT having generated an event
           *          containing management container
           *              containing actionID
           *                  indicating ACTION_ID1
           *              containing referenceTime
           *                  indicating REFERENCETIME1
           *  }
           * Expected behaviour:
           *  ensure that {
           *      when {
           *          the IUT receives an AppDENM_update request associated with ACTION_ID1 from the application layer
           *      }
           *      then {
           *          the IUT sends a valid DENM
           *              containing management container
           *                  containing actionID
           *                      indicating ACTION_ID1
           *                  and containing referenceTime
           *                      indicating CLT > REFERENCETIME1
           *      }
           *  }
           * </pre>
           *
           * @see     ETSI TS 102 869-2 v1.4.1 TP/DEN/EVUP/BV-03, ETSI EN 302 637-3, clause 6.1.2.2
           */

          testcase TC_DEN_EVUP_BV_03() runs on ItsDenm system ItsDenmSystem {
             
              f_DEN_EVUP_BV_03();
             
          } // end TC_DEN_EVUP_BV_03
         
          /**
           * @desc    Check that DEN Basic Service does not send any update DENM if actionID is not in originating ITS-S message table
           * <pre>        
           * PICS Selection: none
           * Initial conditions:
           *  with {
           *      the IUT being in the "initial state"
           *      and the IUT having generated an event
           *      and the IUT not having sent an event being associated with actionID ACTION_ID1
           *          containing originatorStationID
           *              indicating its own stationID
           *          and containing sequenceNumber
           *              indicating SEQ1
           *  }
           * Expected behaviour:
           *  ensure that {
           *      when {
           *          the IUT is requested to update an event associated to ACTION_ID1
           *      }
           *      then {
           *          the IUT does not send send any DENM for this event
           *      }
           *  }
           * </pre>
           *
           * @see     ETSI TS 102 869-2 v1.4.1 TP/DEN/EVUP/BO-04, ETSI EN 302 637-3, clause 8.1.2
           */

          testcase TC_DEN_EVUP_BO_04() runs on ItsDenm system ItsDenmSystem {
             
              f_DEN_EVUP_BO_04();
             
          } // end TC_DEN_EVUP_BO_04
         
      } // end denEventUpdate
     
      // 5.2.1.4
      group denEventTermination {
         
          /**
           * @desc    Check that DEN Basic Service generates a cancellation DENM when application indicates the
           *          premature termination of an event for which it is the originator
           * <pre>        
           * PICS Selection: none
           * Initial conditions:
           *  with {
           *      the IUT being in the "initial state"
           *      and the IUT having generated an event
           *          containing management container
           *              containing actionID
           *                  indicating ACTION_ID1
           *              and containing validityDuration
           *                  indicating DURATION_1
           *  }
           * Expected behaviour:
           *  ensure that {
           *      when {
           *          the IUT receives an AppDENM_termination request associated to ACTION_ID1 from the application layer
           *      }
           *      then {
           *          the IUT sends a valid DENM
           *              containing management container
           *                  containing actionID
           *                      indicating ACTION_ID1
           *                  and containing termination
           *                     indicating value isCancellation
           *      }
           *  }
           * </pre>
           *
           * @see     ETSI TS 102 869-2 v1.4.1 TP/DEN/EVTR/BV-01, ETSI EN 302 637-3, clauses 6.1.2.4, 8.2.1.3
           */

          testcase TC_DEN_EVTR_BV_01() runs on ItsDenm system ItsDenmSystem {
             
              f_DEN_EVTR_BV_01();
             
          } // end TC_DEN_EVTR_BV_01
         
          /**
           * @desc    Check that DEN Basic Service generates a negation DENM when application indicates the
           *          premature termination of an event for which it is not the originator
           * <pre>        
           * PICS Selection: none
           * Initial conditions:
           *  with {
           *      the IUT being in the "initial state"
           *      and the IUT having received an event
           *          containing management container
           *              containing actionID
           *                  indicating ACTION_ID1
           *                      containing originatorStationID
           *                          indicating stationID different from its own stationID
           *  }
           * Expected behaviour:
           *  ensure that {
           *      when {
           *          the IUT receives an AppDENM_termination request associated to ACTION_ID1 from the application layer
           *      }
           *      then {
           *          the IUT sends a valid DENM
           *              containing management container
           *                  containing actionID
           *                      indicating ACTION_ID1
           *                  and containing termination
           *                      indicating value isNegation
           *      }
           *  }
           * </pre>
           *
           * @see     ETSI TS 102 869-2 v1.4.1 TP/DEN/EVTR/BV-02, ETSI EN 302 637-3, clause 6.1.2.4
           */

          testcase TC_DEN_EVTR_BV_02() runs on ItsDenm system ItsDenmSystem {
             
              f_DEN_EVTR_BV_02();
             
          } // end TC_DEN_EVTR_BV_02
         
          /**
           * @desc   Check that referenceTime is set to the latest value received for this event in negation DENM
           * <pre>        
           * PICS Selection: none
           * Initial conditions:
           *  with {
           *      the IUT being in the "initial state"
           *      and the IUT having received an event
           *          containing management container
           *              containing actionID
           *                  indicating ACTION_ID1
           *                      containing originatorStationID
           *                          indicating stationID different from its own stationID
           *              and containing referenceTime
           *                  indicating REFERENCETIME1
           *      and the IUT having received an event
           *          containing management container
           *              containing actionID
           *                  indicating ACTION_ID1
           *              and containing referenceTime
           *                  indicating REFERENCETIME2 > REFERENCETIME1
           *  }
           * Expected behaviour:
           *  ensure that {
           *      when {
           *          the IUT receives an AppDENM_termination request associated to ACTION_ID1 from the application layer
           *      }
           *      then {
           *          the IUT sends a valid DENM
           *              containing management container
           *                  containing actionID
           *                      indicating ACTION_ID1
           *                  and containing referenceTime
           *                      indicating value REFERENCETIME2
           *                  and containing termination
           *                      indicating value isNegation
           *      }
           *  }
           * </pre>
           * @see     ETSI TS 102 869-2 v1.4.1 TP/DEN/EVTR/BV-03, ETSI EN 302 637-3, clauses 6.1.2.4, 8.2.1.3
           */

          testcase TC_DEN_EVTR_BV_03() runs on ItsDenm system ItsDenmSystem {
             
              f_DEN_EVTR_BV_03();
             
          } // end TC_DEN_EVTR_BV_03
         
          /**
           * @desc    Check that situation container, location container  and alacarte container are not present in a cancellation DENM
           * <pre>        
           * PICS Selection: none
           * Initial conditions:
           *  with {
           *      the IUT being in the "initial state"
           *      and the IUT having generated an event
           *          containing management container
           *              containing actionID
           *                  indicating ACTION_ID1
           *  }
           * Expected behaviour:
           *  ensure that {
           *      when {
           *          the IUT receives an AppDENM_termination request associated to ACTION_ID1 from the application layer
           *      }
           *      then {
           *          the IUT sends a valid DENM
           *              containing management container
           *                  containing actionID
           *                      indicating ACTION_ID1
           *                  and containing termination
           *                      indicating value isCancellation
           *              and not containing situation container
           *              and not containing location container
           *              and not containing alacarte container
           *      }
           *  }
           * </pre>
           *
           * @see     ETSI TS 102 869-2 v1.4.1 TP/DEN/EVTR/BV-04, ETSI EN 302 637-3, clause 7.1.1
           */

          testcase TC_DEN_EVTR_BV_04() runs on ItsDenm system ItsDenmSystem {
             
              f_DEN_EVTR_BV_04();
             
          } // end TC_DEN_EVTR_BV_04
         
          /**
           * @desc    Check that situation container, location container and alacarte container are not present in a negation DENM
           * <pre>        
           * PICS Selection: none
           * Initial conditions:
           *  with {
           *      the IUT being in the "initial state"
           *      and the IUT having received an event
           *          containing management container
           *              containing actionID
           *                  indicating ACTION_ID1
           *                      containing originatorStationID
           *                          indicating stationID different from its own stationID
           *  }
           * Expected behaviour:
           *  ensure that {
           *      when {
           *          the IUT receives an AppDENM_termination request associated to ACTION_ID1 from the application layer
           *      }
           *      then {
           *          the IUT sends a valid DENM
           *              containing management container
           *                  containing actionID
           *                      indicating ACTION_ID1
           *                  and containing termination
           *                      indicating value isNegation
           *              and not containing situation container
           *              and not containing location container
           *              and not containing alacarte container
           *      }
           *  }
           * </pre>
           *
           * @see     ETSI TS 102 869-2 v1.4.1 TP/DEN/EVTR/BV-05, ETSI EN 302 637-3, clause 7.1.1
           */

          testcase TC_DEN_EVTR_BV_05() runs on ItsDenm system ItsDenmSystem {
             
              f_DEN_EVTR_BV_05();
             
          } // end TC_DEN_EVTR_BV_05
         
          /**
           * @desc    Check that DEN Basic Service does not send any termination DENM if actionID is not in
           *          originating ITS-S message table or receiving ITS-S message table (own stationID)
           * <pre>        
           * PICS Selection: none
           * Initial conditions:
           *  with {
           *      the IUT being in the "initial state"
           *      and the IUT having generated several events
           *      and the IUT not having send event being associated with ACTION_ID1
           *          containing originatingStationID
           *              indicating its own stationID
           *          and containing sequenceNumber
           *              indicating SEQ1
           *  }
           * Expected behaviour:
           *  ensure that {
           *      when {
           *          the IUT is requested to terminate an event associated to ACTION_ID1
           *              containing originatingStationID
           *                  indicating its own stationID
           *              and containing sequenceNumber
           *                  indicating SEQ1
           *      }
           *      then {
           *          the IUT does not send send any termination DENM for this event
           *      }
           *  }
           *  NOTE: Event associated to ACTION_ID1 cannot be present in receiving ITS-S message
           *        table as its stationID is IUT’s stationID (see TP/DEN/EVTR/BO-07)
           * </pre>
           *
           * @see     ETSI TS 102 869-2 v1.4.1 TP/DEN/EVTR/BO-06, ETSI EN 302 637-3, clauses 8.2.2
           */

          testcase TC_DEN_EVTR_BO_06() runs on ItsDenm system ItsDenmSystem {
             
              f_DEN_EVTR_BO_06();
             
          } // end TC_DEN_EVTR_BO_06
         
          /**
           * @desc    Check that DEN Basic Service does not send any termination DENM if actionID is not in
           *          originating ITS-S message table or receiving ITS-S message table (other stationID)
           * <pre>        
           * PICS Selection: none
           * Initial conditions:
           *  with {
           *      the IUT being in the "initial state"
           *      and the IUT having received several events
           *      and the IUT not having received event being associated with ACTION_ID1
           *          containing originatingStationID
           *              indicating STATION_ID1 different from its own stationID
           *          and containing sequenceNumber
           *              indicating SEQ1
           *  }
           * Expected behaviour:
           *  ensure that {
           *      when {
           *          the IUT is requested to terminate an event associated to ACTION_ID1
           *              containing originatingStationID
           *                  indicating STATION_ID1
           *              and containing sequenceNumber
           *                  indicating SEQ1
           *      }
           *      then {
           *          the IUT does not send send any termination DENM for this event
           *      }
           *  }
           *  NOTE: Event associated to ACTION_ID1 cannot be present in originating ITS-S message table as its
           *        stationID is not IUT’s stationID (see TP/DEN/EVTR/BO-06)
           * </pre>
           *
           * @see     ETSI TS 102 869-2 v1.4.1 TP/DEN/EVTR/BO-07, ETSI EN 302 637-3, clauses 8.2.2
           */

          testcase TC_DEN_EVTR_BO_07() runs on ItsDenm system ItsDenmSystem {
             
              f_DEN_EVTR_BO_07();
             
          } // end TC_DEN_EVTR_BV_07
         
          /**
           * @desc    Check that referenceTime is set to to the current time when generating a cancellation DENM
           * <pre>        
           * PICS Selection: none
           * Initial conditions:
           *  with {
           *      the IUT being in the "initial state"
           *      and the IUT having generated an event
           *          containing management container
           *              containing actionID
           *                  indicating ACTION_ID1
                   *              and containing validityDuration
                   *                      indicating DURATION_1
           *              and containing referenceTime
           *                  indicating REFERENCETIME1
           *  }
           * Expected behaviour:
           *  ensure that {
           *      when {
           *          the IUT receives an AppDENM_termination request associated with ACTION_ID1 from the application layer
           *      }
           *      then {
           *          the IUT sends a valid DENM
           *              containing management container
           *                  containing actionID
           *                      indicating ACTION_ID1
                   *                  and containing termination
                   *                          indicating value isCancellation
           *                  and containing referenceTime
           *                      indicating CLT
           *      }
           *  }
           * </pre>
           *
           * @see     ETSI TS 102 869-2 v1.4.1 TP/DEN/EVTR/BV-08, ETSI EN 302 637-3, clause 8.2.1.3
           */

          testcase TC_DEN_EVTR_BV_08() runs on ItsDenm system ItsDenmSystem {
             
              f_DEN_EVTR_BV_08();
             
          } // end TC_DEN_EVTR_BV_08
         
      } // end denEventTermination
     
      // 5.2.1.5
      group denMessageRepetition {
         
          /**
           * @desc    Check that DEN Basic Sercive repeats DENM transmission according to repetitionInterval parameter provided by application
           * <pre>        
           * PICS Selection: none
           * Initial conditions:
           *  with {
           *      the IUT being in the "initial state"
           *      and the IUT having received an AppDENM_trigger request from the application layer
           *          containing repetitionInterval
           *              indicating INTERVAL_1
           *          and containing repetitionDuration
           *              indicating DURATION_1
           *          and containing validityDuration
           *              indicating DURATION_2 > DURATION_1
           *      and the IUT having generated an the corresponding event
           *          containing management container
           *              containing actionID
           *                  indicating ACTION_ID1
           *              and containing validityDuration
           *                  indicating DURATION_1
           *              and containing transmissionInterval
           *                  indicating INTERVAL_1
           *  }
           * Expected behaviour:
           *  ensure that {
           *      when {
           *          the IUT is alerted of expiration of the time associated with INTERVAL_1
           *      }
           *      then {
           *          the IUT repeats the transmission of the valid DENM associated with ACTION_ID1
           *      }
           *  }
           * </pre>
           *
           * @see     ETSI TS 102 869-2 v1.4.1 TP/DEN/EVRP/TI-01, ETSI EN 302 637-3, clause 6.1.2.3 and 8.2.2
           */

          testcase TC_DEN_EVRP_TI_01() runs on ItsDenm system ItsDenmSystem {
             
              f_DEN_EVRP_TI_01();
             
          } // end TC_DEN_EVRP_TI_01
         
          /**
           * @desc    Check that the repeated DENM is always the most up-to-date message
           * <pre>        
           * PICS Selection: none
           * Initial conditions:
           *  with {
           *      the IUT being in the "initial state"
           *      and the IUT having received an AppDENM_trigger request from the application layer
           *          containing repetitionInterval
           *              indicating INTERVAL_1
           *          and containing repetitionDuration
           *              indicating DURATION_1
           *          and containing validityDuration
           *              indicating DURATION_2 > DURATION_1
           *      and the IUT having generated an the corresponding event
           *          containing management container
           *              containing actionID
           *                  indicating ACTION_ID1
           *      and the IUT having generated an update of the event associated with ACTION_ID1 modifying partly the event
           *  }
           * Expected behaviour:
           *  ensure that {
           *      when {
           *          the IUT is alerted of expiration of the time associated with INTERVAL_1
           *      }
           *      then {
           *          the IUT repeats the transmission of the valid DENM associated with ACTION_ID1
           *      }
           *  }
           * </pre>
           *
           * @see     ETSI TS 102 869-2 v1.4.1 TP/DEN/EVRP/BV-02, ETSI EN 302 637-3, clause 6.1.2.3 and 8.2.2
           */

          testcase TC_DEN_EVRP_BV_02() runs on ItsDenm system ItsDenmSystem {
             
              f_DEN_EVRP_BV_02();
             
          } // end TC_DEN_EVRP_BV_02
         
          /**
           * @desc    Check that DEN Basic Service stops retransmitting DENM after event’s validityDuration
           *          expiration
           * <pre>        
           * PICS Selection: none
           * Initial conditions:
           *  with {
           *      the IUT being in the "initial state"
           *      and the IUT having received an AppDENM_trigger request from application layer
           *          containing repetitionInterval
           *              indicating INTERVAL_1
           *          and containing repetitionDuration
           *              indicating DURATION_1
           *          and containing validityDuration
           *              indicating DURATION_2 > DURATION_1
           *      and the IUT having generated the corresponding event
           *          containing management container
           *              containing actionID
           *                  indicating ACTION_ID1
           *              and containing validityDuration
           *                  indicating DURATION_1
           *      and the IUT having repeated (one or more times) the transmission of the valid DENM associated with ACTION_ID1
           *  }
           * Expected behaviour:
           *  ensure that {
           *      when {
           *          the IUT is alerted of expiration of the time associated with DURATION_2
           *      }
           *      then {
           *          the IUT stops the retransmission of the DENM associated with ACTION_ID1
           *      }
           *  }
           * </pre>
           *
           * @see     ETSI TS 102 869-2 v1.4.1 TP/DEN/EVRP/BV-03, ETSI EN 302 637-3, clauses 6.1.2.4 and 8.2.2
           */

          testcase TC_DEN_EVRP_BV_03() runs on ItsDenm system ItsDenmSystem {
             
              f_DEN_EVRP_BV_03();
             
          } // end TC_DEN_EVRP_BV_03
         
          /**
           * @desc    Check that DEN Basic Service stops retransmitting DENM after event’s repetitionDuration
           *          expiration
           * <pre>        
           * PICS Selection: none
           * Initial conditions:
           *  with {
           *      the IUT being in the "initial state"
           *      and the IUT having received an AppDENM_trigger request from application layer
           *          containing repetitionInterval
           *              indicating INTERVAL_1
           *          and containing repetitionDuration
           *              indicating DURATION_1
           *          and containing validityDuration
           *              indicating DURATION_2 > DURATION_1
           *      and the IUT having generated the corresponding event
           *          containing management container
           *              containing actionID
           *                  indicating ACTION_ID1
           *              and containing validityDuration
           *                  indicating DURATION_2
           *      and the IUT having repeated (one or more times) the transmission of the valid DENM associated with ACTION_ID1
           *  }
           * Expected behaviour:
           *  ensure that {
           *      when {
           *          the IUT is alerted of expiration of the time associated with DURATION_2
           *      }
           *      then {
           *          the IUT stops the retransmission of the most up-to-date valid DENM associated with ACTION_ID1
           *      }
           *  }
           * </pre>
           *
           * @see     ETSI TS 102 869-2 v1.4.1 TP/DEN/EVRP/BV-04, ETSI EN 302 637-3, clause 8.2.2
           */

          testcase TC_DEN_EVRP_BV_04() runs on ItsDenm system ItsDenmSystem {
             
              f_DEN_EVRP_BV_04();
             
          } // end TC_DEN_EVRP_BV_04
         
          /**
           * @desc    Check that DEN Basic Service does not repeat transmission of DENM if repetitionInterval is
           *          not provided by application
           * <pre>        
           * PICS Selection: none
           * Initial conditions:
           *  with {
           *      the IUT being in the "initial state"
           *      and the IUT having received an AppDENM_trigger request from application layer
           *          not containing repetitionInterval
           *      and the IUT having generated an the corresponding event
           *          containing management container
           *              containing actionID
           *                  indicating ACTION_ID1
           *  }
           * Expected behaviour:
           *  ensure that {
           *      when {
           *          the IUT has detected that repetitionInterval is not provided for the event associated with ACTION_ID1
           *      }
           *      then {
           *          the IUT does not repeat the transmission of the valid DENM associated with ACTION_ID1
           *      }
           *  }
           * </pre>
           *
           * @see     ETSI TS 102 869-2 v1.4.1 TP/DEN/EVRP/BV-05, ETSI EN 302 637-3, clause 8.1.2
           */

          testcase TC_DEN_EVRP_BV_05() runs on ItsDenm system ItsDenmSystem {
             
              f_DEN_EVRP_BV_05();
             
          } // end TC_DEN_EVRP_BV_05
         
          /**
           * @desc    Check that DEN Basic Service does not repeat transmission of DENM if repetitionDuration is
           *          not provided by application
           * <pre>        
           * PICS Selection: none
           * Initial conditions:
           *  with {
           *      the IUT being in the "initial state"
           *      and the IUT having received an AppDENM_trigger request from application layer
           *          not containing repetitionDuration
           *      and the IUT having generated an the corresponding event
           *          containing management container
           *              containing actionID
           *                  indicating ACTION_ID1
           *  }
           * Expected behaviour:
           *  ensure that {
           *      when {
           *          the IUT has detected that repetitionDuration is not provided for the event associated with ACTION_ID1
           *      }
           *      then {
           *          the IUT does not repeat the transmission of the valid DENM associated with ACTION_ID1
           *      }
           *  }
           * </pre>
           *
           * @see     ETSI TS 102 869-2 v1.4.1 TP/DEN/EVRP/BV-06, ETSI EN 302 637-3, clause 8.1.2
           */

          testcase TC_DEN_EVRP_BV_06() runs on ItsDenm system ItsDenmSystem {
             
              f_DEN_EVRP_BV_06();
             
          } // end TC_DEN_EVRP_BV_06
           
          /**
           * @desc    Check that existing actionID in originating ITS-S are updated when stationID is modified
           *
           * <pre>        
           * PICS Selection: none
           * Initial conditions:
           *  with {
           *      the IUT being in the "initial state"
           *      and the IUT having received an AppDENM_trigger request from application layer
           *            containing repetitionInterval
           *                    indicating INTERVAL_1
           *            and containing repetitionDuration
           *                    indicating DURATION_1
           *            and containing validityDuration
           *                    indicating DURATION_2 > DURATION_1
           *      and the IUT having generated the corresponding event
           *            containing management container
           *                    containing actionID
           *                            containing originatororiginatingStationID
           *                                    indicating STATION_ID_1
           *                    and containing validityDuration
           *                            indicating DURATION_1
           *     and the IUT having changed its StationID
           *  }
           * Expected behaviour:
           *  ensure that {
           *      when {
           *          the IUT changes its StationID and is alerted of expiration of the time associated with INTERVAL_1
           *      }
           *      then {
           *                    the IUT repeats the transmission of the valid DENM
           *                            containing management container
           *                                    containing actionID
           *                                            containing originatingStationID
           *                                                    indicating its new StationID
           *      }
           *  }
           * </pre>
           *
           * @see     ETSI TS 102 869-2 v1.4.1 TP/DEN/EVRP/BV-08, ETSI EN 302 637-3, clause 6.1.1.2
           */

          testcase TC_DEN_EVRP_BV_08() runs on ItsDenm system ItsDenmSystem {
             
              f_DEN_EVRP_BV_08();
             
          } // end TC_DEN_EVRP_BV_08
           
          /**
           * @desc              Check that actionID is not modified in repetitions of DENM if stationID is not modified
           *
           * <pre>        
           * PICS Selection: none
           * Initial conditions:
           *  with {
           *      the IUT being in the "initial state"
           *      and the IUT having received an AppDENM_trigger request from application layer
           *            containing repetitionInterval
           *                    indicating INTERVAL_1
           *            and containing repetitionDuration
           *                    indicating DURATION_1
           *            and containing validityDuration
           *                    indicating DURATION_2 > DURATION_1
           *      and the IUT having generated the corresponding event
           *            containing management container
           *                    containing actionID
           *                            indicating ACTION_ID_1
           *                    and containing validityDuration
           *                            indicating DURATION_1
           *     and the IUT not having changed its StationID
           *  }
           * Expected behaviour:
           *  ensure that {
           *      when {
           *          the IUT is alerted of expiration of the time associated with INTERVAL_1
           *      }
           *      then {
           *                    the IUT repeats the transmission of the valid DENM
           *                            containing management container
           *                                    containing actionID
           *                                            indicating its ACTION_ID_1
           *      }
           *  }
           * </pre>
           *
           * @see     ETSI TS 102 869-2 v1.4.1 TP/DEN/EVRP/BV-09, ETSI EN 302 637-3, clause 8.2.1.2
           */

          testcase TC_DEN_EVRP_BV_09() runs on ItsDenm system ItsDenmSystem {
             
              f_DEN_EVRP_BV_09();
             
          } // end TC_DEN_EVRP_BV_09
           
          /**
           * @desc              Check that actionID is not modified in repetitions of DENM if stationID is not modified
           *
           * <pre>        
           * PICS Selection: none
           * Initial conditions:
           *  with {
           *      the IUT being in the "initial state"
           *      and the IUT having received an AppDENM_trigger request from application layer
           *            containing repetitionInterval
           *                    indicating INTERVAL_1
           *            and containing repetitionDuration
           *                    indicating DURATION_1
           *            and containing validityDuration
           *                    indicating DURATION_2 > DURATION_1
           *      and the IUT having generated the corresponding event
           *            containing management container
           *                    containing actionID
           *                            indicating ACTION_ID_1
           *                    and containing validityDuration
           *                            indicating DURATION_2
           *                    and containing referenceTime
           *                            indicating REFERENCE_TIME_1
           *  }
           * Expected behaviour:
           *  ensure that {
           *      when {
           *          the IUT is alerted of expiration of the time associated with INTERVAL_1
           *      }
           *      then {
           *                    the IUT repeats the transmission of the valid DENM
           *                            containing management container
           *                                    containing actionID
           *                                            indicating its ACTION_ID_1
           *                                    and containing referenceTime
           *                                            indicating REFERENCE_TIME_1
           *      }
           *  }
           * </pre>
           *
           * @see     ETSI TS 102 869-2 v1.4.1 TP/DEN/EVRP/BV-10, ETSI EN 302 637-3, clause 8.2.1.2
           */

          testcase TC_DEN_EVRP_BV_10() runs on ItsDenm system ItsDenmSystem {
             
              f_DEN_EVRP_BV_10();
             
          } // end TC_DEN_EVRP_BV_10
           
          /**
           * @desc              Check that DEN Basic Service stops retransmitting DENM after event's validityDuration expiration,
           *            when validityDuration was not provided
           *
           * <pre>        
           * PICS Selection: none
           * Initial conditions:
           *  with {
           *      the IUT being in the "initial state"
           *      and the IUT having received an AppDENM_trigger request from application layer
           *            containing repetitionInterval
           *                    indicating INTERVAL_1
           *            and containing repetitionDuration
           *                    indicating DURATION_1 > defaultValidityDuration
           *            and not containing validityDuration
           *      and the IUT having generated the corresponding event
           *            containing management container
           *                    containing actionID
           *                            indicating ACTION_ID_1
           *  }
           * Expected behaviour:
           *  ensure that {
           *      when {
           *          the IUT is alerted of expiration of the defaultValidityDuration
           *      }
           *      then {
           *                    the IUT stops the retransmission of the DENM associated with ACTION_ID1
           *      }
           *  }
           * </pre>
           *
           * @see     ETSI TS 102 869-2 v1.4.1 TP/DEN/EVRP/BV-11, ETSI EN 302 637-3, clause 8.2.1.5
           */

          testcase TC_DEN_EVRP_BV_11() runs on ItsDenm system ItsDenmSystem {
             
              f_DEN_EVRP_BV_11();
             
          } // end TC_DEN_EVRP_BV_11
         
      } // end denMessageRepetition

      // 5.2.1.6
      group denMessageLowerLayerParameters {
         
          /**
           * @desc    Check that DENM is encapsulated in BTP type B packet
           * <pre>        
           * PICS Selection: PICS_DENM_GENERATION
           * Initial conditions:
           *  with {
           *      the IUT being in the "initial state"
           *  }
           * Expected behaviour:
           *  ensure that {
           *      when {
           *          a DENM is generated
           *      }
           *      then {
           *          the IUT sends a DENM
           *              encapsulated in a BTP-B packet
           *      }
           *  }
           * </pre>
           *
           * @see     ETSI TS 102 869-2 v1.4.1 TP/DEN/PAR/BV-01, EN 302 637-3 clause 5.4.2.2
           */

          testcase TC_DEN_PAR_BV_01() runs on ItsDenm system ItsDenmSystem {
             
              f_DEN_PAR_BV_01();
             
          } // end TC_DEN_PAR_BV_01

          /**
           * @desc    Check that DENM is encapsulated in a GBC packet
           * <pre>        
           * PICS Selection: PICS_DENM_GENERATION
           * Initial conditions:
           *  with {
           *      the IUT being in the "initial state"
           *  }
           * Expected behaviour:
           *  ensure that {
           *      when {
           *          a DENM is generated
           *      }
           *      then {
           *          the IUT sends a DENM
           *              encapsulated in a GBC packet
           *      }
           *  }
           * </pre>
           *
           * @see     ETSI TS 102 869-2 v1.4.1 TP/DEN/PAR/BV-02, EN 302 637-3 clause 5.4.2.2
           */

          testcase TC_DEN_PAR_BV_02() runs on ItsDenm system ItsDenmSystem {
             
              f_DEN_PAR_BV_02();
             
          } // end TC_DEN_PAR_BV_02          

      } // end denMessageLowerLayerParameters
               
    } // end denMessageTransmission
   
    // 5.2.2
    group denMessageReception {
       
        /**
         * @desc    Check that receiving ITS-S transmits DENM to application if it concerns an unknown ActionID and if it is not a termination DENM
         *        
         * <pre>
         * PICS Selection: none
         * Initial conditions:
         *  with {
         *      the IUT being in the "initial state"
         *      and the IUT not having received DENM
         *          containing management container
         *              containing actionID
         *                  indicating ACTION_ID1
         *  }
         * Expected behaviour:
         *  ensure that {
         *      when {
         *          the IUT receives a DENM that is not a termination
         *              containing management container
         *                  containing actionID
         *                      indicating ACTION_ID1
         *      }
         *      then {
         *          the IUT transmits the DENM content to upper layer
         *      }
         *  }
         * </pre>
         *
         * @see     ETSI TS 102 869-2 v1.4.1 TP/DEN/MSRV/BV-01, ETSI EN 302 637-3, clause 8.4.2
         */

        testcase TC_DEN_MSRV_BV_01() runs on ItsDenm system ItsDenmSystem {
             
            f_DEN_MSRV_BV_01();
             
        } // end TC_DEN_MSRV_BV_01
       
        /**
         * @desc    Check that receiving ITS-S transmits DENM to application if it concerns a known ActionID
         *          and referenceTime is greater than highest value received for this ActionID
         * <pre>
         * PICS Selection: none
         * Initial conditions:
         *  with {
         *      the IUT being in the "initial state"
         *      and the IUT having received DENM
         *          containing management container
         *              containing actionID
         *                  indicating ACTION_ID1
         *              and containing referenceTime
         *                  indicating  REFERENCETIME_1
         *  }
         * Expected behaviour:
         *  ensure that {
         *      when {
         *          the IUT receives a DENM
         *              containing management container
         *                  containing actionID
         *                      indicating ACTION_ID1
         *                  and containing referenceTime
         *                      indicating REFERENCETIME_2 greater than REFERENCETIME_1

         *      }
         *      then {
         *          the IUT transmits the DENM content to upper layer
         *      }
         *  }
         * </pre>
         *
         * @see     ETSI TS 102 869-2 v1.4.1 TP/DEN/MSRV/BV-02, ETSI EN 302 637-3, clause 8.4.2
         */

        testcase TC_DEN_MSRV_BV_02() runs on ItsDenm system ItsDenmSystem {
             
            f_DEN_MSRV_BV_02();
             
        } // end TC_DEN_MSRV_BV_02
               
        /**
         * @desc    Check that receiving ITS-S discards termination DENM if it concerns an unknown ActionID (own actionID)
         * <pre>
         * PICS Selection: none
         * Initial conditions:
         *  with {
         *      the IUT being in the "initial state"
         *      and the IUT having received several events
         *      and the IUT not having received DENM
         *          containing actionID
         *              indicating ACTION_ID1
         *  }
         * Expected behaviour:
         *  ensure that {
         *      when {
         *          the IUT receives a termination DENM
         *              containing actionID
         *                  indicating ACTION_ID1
         *      }
         *      then {
         *          the IUT discards the DENM
         *          and the IUT does not forward the DENM content to upper layer
         *      }
         *  }
         * </pre>
         *
         * @see     ETSI TS 102 869-2 v1.4.1 TP/DEN/MSRV/BO-03, ETSI EN 302 637-3, clause 8.3.2
         */

        testcase TC_DEN_MSRV_BO_03() runs on ItsDenm system ItsDenmSystem {
             
            f_DEN_MSRV_BO_03();
             
        } // end TC_DEN_MSRV_BO_03
       
        /**
         * @desc    Check that receiving ITS-S discards termination DENM if it concerns an unknown ActionID (other actionID)
         * <pre>
         * PICS Selection: none
         * Initial conditions:
         *  with {
         *      and the IUT having received several events
         *      and the IUT not having received DENM
         *          containing actionID
         *              indicating ACTION_ID1
         *  }
         * Expected behaviour:
         *  ensure that {
         *      when {
         *          the IUT receives a termination DENM
         *              containing actionID
         *                  indicating ACTION_ID1
         *      }
         *      then {
         *          the IUT discards the DENM
         *          and the IUT does not forward the DENM content to upper layer
         *      }
         *  }
         * </pre>
         *
         * @see     ETSI TS 102 869-2 v1.4.1 TP/DEN/MSRV/BO-04, ETSI EN 302 637-3, clause 8.3.2
         */

        testcase TC_DEN_MSRV_BO_04() runs on ItsDenm system ItsDenmSystem {
             
            f_DEN_MSRV_BO_04();
             
        } // end TC_DEN_MSRV_BO_04
       
        /**
         * @desc    Check that receiving ITS-S discards DENM if referenceTime is lower than highest value received for this ActionID
         * <pre>
         * PICS Selection: none
         * Initial conditions:
         *  with {
         *      the IUT being in the "initial state"
         *      and the IUT having received DENM
         *          containing management container
         *              containing actionID
         *                  indicating ACTION_ID1
         *              and containing referenceTime
         *                  indicating REFERENCETIME_1
         *  }
         * Expected behaviour:
         *  ensure that {
         *      when {
         *          the IUT receives a DENM
         *              containing management container
         *                  containing actionID
         *                      indicating ACTION_ID1
         *                  and containing referenceTime
         *                      indicating REFERENCETIME_2 lower than REFERENCETIME_1
         *      }
         *      then {
         *          the IUT discards the DENM
         *          and the IUT does not forward the DENM content to upper layer
         *      }
         *  }
         * </pre>
         *
         * @see     ETSI TS 102 869-2 v1.4.1 TP/DEN/MSRV/BO-05, ETSI EN 302 637-3, clause 8.3.2
         */

        testcase TC_DEN_MSRV_BO_05() runs on ItsDenm system ItsDenmSystem {
             
            f_DEN_MSRV_BO_05();
             
        } // end TC_DEN_MSRV_BO_05
       
        /**
         * @desc    Check that receiving ITS-S discards DENM if detectionTime is smaller than highest value received for this ActionID
         *          
         * <pre>
         * PICS Selection: none
         * Initial conditions:
         *  with {
         *      the IUT being in the "initial state"
         *      and the IUT having received DENM
         *          containing management container
         *              containing actionID
         *                  indicating ACTION_ID1
         *              and containing referenceTime
         *                  indicating REFERENCETIME_1
         *              and containing detectionTime
         *                  indicating TIME_1
         *  }
         * Expected behaviour:
         *  ensure that {
         *      when {
         *          the IUT receives a DENM
         *              containing management container
         *                  containing actionID
         *                      indicating ACTION_ID1
         *                  and containing referenceTime
         *                      indicating REFERENCETIME_1
         *                  and containing detectionTime
         *                      indicating TIME_2 not more recent than TIME_1
         *      }
         *      then {
         *          the IUT discards the DENM
         *          and the IUT does not forward the DENM content to upper layer
         *      }
         *  }
         * </pre>
         *
         * @see     ETSI TS 102 869-2 v1.4.1 TP/DEN/MSRV/BO-06, ETSI EN 302 637-3, clause 8.3.2
         */

        testcase TC_DEN_MSRV_BO_06() runs on ItsDenm system ItsDenmSystem {
             
            f_DEN_MSRV_BO_06();
             
        } // end TC_DEN_MSRV_BO_06
       
        /**
         * @desc    Check that receiving ITS-S transmits DENM to application if it concerns a known ActionID and referenceTime
         *          is equal to highest received value and detectionTime is more recent
         * <pre>
         * PICS Selection: none
         * Initial conditions:
         *  with {
         *      the IUT being in the "initial state"
         *      and the IUT having received DENM
         *          containing management container
         *              containing actionID
         *                  indicating ACTION_ID1
         *              and containing referenceTime
         *                  indicating REFERENCETIME_1
         *              and containing detectionTime
         *                  indicating TIME_1
         *  }
         * Expected behaviour:
         *  ensure that {
         *      when {
         *          the IUT receives a DENM
         *              containing management container
         *                  containing actionID
         *                      indicating ACTION_ID1
         *                  and containing referenceTime
         *                      indicating REFERENCETIME_1
         *                  and containing detectionTime
         *                      indicating TIME_2 more recent than TIME_1
         *      }
         *      then {
         *          the IUT transmits the DENM content to upper layer
         *      }
         *  }
         * </pre>
         *
         * @see     ETSI TS 102 869-2 v1.4.1 TP/DEN/MSRV/BV-07, ETSI EN 302 637-3, clause 8.3.2
         */

        testcase TC_DEN_MSRV_BV_07() runs on ItsDenm system ItsDenmSystem {
             
            f_DEN_MSRV_BV_07();
             
        } // end TC_DEN_MSRV_BV_07
       
        /**
         * @desc    Check that receiving ITS-S replies to requestResponseIndication
         *          
         * <pre>
         * PICS Selection: none
         * Initial conditions:
         *  with {
         *      the IUT being in the "initial state"
         *  }
         * Expected behaviour:
         *  ensure that {
         *      when {
         *          the IUT receives a DENM
         *              containing management container
         *                  containing actionID
         *                      indicating ACTION_ID1
         *              and containing alacarte container
         *                  containing ImpactReductionContainer
         *                      containing requestResponseIndication
         *                              indicating request(0)
         *      }
         *      then {
         *          the IUT sends a DENM
         *              containing management container
         *                  containing actionID
         *                      indicating ACTION_ID2
         *              and containing alacarte container
         *                  containing ImpactReductionContainer
         *                      containing requestResponseIndication
         *                              indicating response(1)
         *      }
         *  }
         * </pre>
         *
         * @see     ETSI TS 102 869-2 v1.4.1 TP/DEN/MSRV/BV-10, ETSI EN 302 637-3, clause B.40
         */

        testcase TC_DEN_MSRV_BV_10() runs on ItsDenm system ItsDenmSystem {
             
            f_DEN_MSRV_BV_10();
             
        } // end TC_DEN_MSRV_BV_10
       
    } // end denMessageReception
   
    // 5.2.3
    group denKeepAliveForwarding {

        /**
         * @desc    Check that forwarding ITS-S forwards DENM if no DENM with same ActionId has been received during forwarding delay
         * <pre>
         * PICS Selection: PICS_KAF
         * Initial conditions:
         *  with {
         *      the IUT being in the "initial state"
         *          and the IUT having received a DENM
         *              containing actionID
         *                  indicating ACTION_ID1
         *              and containing transmissionInterval
         *                  indicating TRANS_INTERVAL1
         *              and containing validityDuration
         *                  indicating value more than 3 times greater than TRANS_INTERVAL1
         *          and the IUT having starting timer T_Forwarding for this DENM
         *          and the IUT not having received further DENM
         *              containing actionID
         *                  indicating ACTION_ID1
         *  }
         * Expected behaviour:
         *  ensure that {
         *      when {
         *          the timer T_Forwarding expires
         *      }
         *      then {
         *          the IUT reconstructs and sends the DENM associated to ACTION_ID1
         *      }
         *  }
         * </pre>
         *
         * @see     ETSI TS 102 869-2 v1.4.1 TP/DEN/KAFW/BV-01, ETSI EN 302 637-3, clause 8.2.2
         */

        testcase TC_DEN_KAFW_BV_01() runs on ItsDenm system ItsDenmSystem {
             
            f_DEN_KAFW_BV_01();
             
        } // end TC_DEN_KAFW_BV_01
       
        /**
         * @desc    Check that forwarding ITS-S forwards DENM if no DENM with same ActionId and referenceTime greater
         *          or equal to the last received DENM has been received during forwarding delay
         * <pre>
         * PICS Selection: PICS_KAF
         * Initial conditions:
         *  with {
         *      the IUT being in the "initial state"
         *      and the IUT having received a DENM
         *          containing actionID
         *              indicating ACTION_ID1
         *          and containing transmissionInterval
         *              indicating TRANS_INTERVAL1
         *          and containing referenceTime
         *              indicating REFERENCETIME_1
         *          and containing validityDuration
         *              indicating value more than 3 times greater than TRANS_INTERVAL1
         *      and the IUT having starting timer T_Forwarding for this DENM
         *      and the IUT having received DENM
         *          containing actionID
         *              indicating ACTION_ID1
         *          and containing referenceTime
         *              indicating value REFERENCETIME_2 < REFERENCETIME_1
         *      and the IUT not having received further DENM
         *          containing actionID
         *              indicating ACTION_ID1
         *          and containing referenceTime
         *              indicating value REFERENCETIME_3 > REFERENCETIME_1
         *  }
         * Expected behaviour:
         *  ensure that {
         *      when {
         *          the timer T_Forwarding expires
         *      }
         *      then {
         *          the IUT reconstructs and sends the DENM associated to ACTION_ID1
         *      }
         *  }
         * </pre>
         *
         * @see     ETSI TS 102 869-2 v1.4.1 TP/DEN/KAFW/BV-02, ETSI EN 302 637-3, clause 8.2.2
         */

        testcase TC_DEN_KAFW_BV_02() runs on ItsDenm system ItsDenmSystem {
             
            f_DEN_KAFW_BV_02();
             
        } // end TC_DEN_KAFW_BV_02
               
        /**
         * @desc    Check that forwarding delay is set to min(2*transmissionInterval + rnd(0, 150ms), validityDuration)
         * <pre>
         * PICS Selection: PICS_KAF
         * Initial conditions:
         *  with {
         *      the IUT being in the "initial state"
         *      and the IUT having received a DENM
         *          containing actionID
         *              indicating ACTION_ID1
         *          and containing transmissionInterval
         *              indicating TRANS_INTERVAL1
         *          and containing validityDuration
         *              indicating value DURATION_1 more than 3 times greater than TRANS_INTERVAL1
         *  }
         * Expected behaviour:
         *  ensure that {
         *      when {
         *          the timer T_Forwarding expires
         *      }
         *      then {
         *          the IUT reconstructs and sends the DENM associated to ACTION_ID1 at a point of time corresponding to
         *          min ( 2*transmissionInterval + rnd ( 0, 150ms ), validityDuration )
         *      }
         *  }
         * </pre>
         *
         * @see     ETSI TS 102 869-2 v1.4.1 TP/DEN/KAFW/TI-03, ETSI EN 302 637-3, clause 8.2.1.4
         */

        testcase TC_DEN_KAFW_TI_03() runs on ItsDenm system ItsDenmSystem {
             
            f_DEN_KAFW_TI_03();
             
        } // end TC_DEN_KAFW_TI_03

        /**
         * @desc    Check that Forwarding ITS-S replaces the ITS PDU header of forwarded DENMs
         * <pre>
         * PICS Selection: PICS_KAF
         * Initial conditions:
         *  with {
         *      the IUT being in the "initial state"
         *      and the IUT having received a DENM
         *          containing actionID
         *              indicating ACTION_ID1
         *          and containing transmissionInterval
         *              indicating TRANS_INTERVAL1
         *          and containing validityDuration
         *              indicating value more than 3 times greater than TRANS_INTERVAL1
         *      and the IUT having starting timer T_Forwarding for this DENM
         *      and the IUT not having received further DENM
         *          containing actionID
         *              indicating ACTION_ID1
         *  }
         * Expected behaviour:
         *  ensure that {
         *      when {
         *          the timer T_Forwarding expires
         *      }
         *      then {
         *          the IUT reconstructs and sends the DENM associated to ACTION_ID1
         *              containing ITS PDU header
         *                  containing StationID
         *                      indicating its own stationID
         *      }
         *  }
         * </pre>
         *
         * @see     ETSI TS 102 869-2 v1.4.1 TP/DEN/KAFW/BV-04, ETSI EN 302 637-3, clause 8.2.1.6
         */

        testcase TC_DEN_KAFW_BV_04() runs on ItsDenm system ItsDenmSystem {
             
            f_DEN_KAFW_BV_04();
             
        } // end TC_DEN_KAFW_BV_04

        /**
         * @desc    Check that forwarding ITS-S does not change actionID
         * <pre>
         * PICS Selection: PICS_KAF
         * Initial conditions:
         *  with {
         *      the IUT being in the "initial state"
         *      and the IUT having received a DENM
         *          containing actionID
         *              indicating ACTION_ID1
         *          and containing transmissionInterval
         *              indicating TRANS_INTERVAL1
         *          and containing validityDuration
         *              indicating value more than 3 times greater than TRANS_INTERVAL1
         *      and the IUT having starting timer T_Forwarding for this DENM
         *      and the IUT not having received further DENM
         *          containing actionID
         *              indicating ACTION_ID1
         *  }
         * Expected behaviour:
         *  ensure that {
         *      when {
         *          the timer T_Forwarding expires
         *      }
         *      then {
         *          the IUT reconstructs and sends the DENM
         *              containing management container
         *                  containing actionID
         *                      indicating ACTION_ID1
         *  }
         * </pre>
         *
         * @see     ETSI TS 102 869-2 v1.4.1 TP/DEN/KAFW/BV-05, ETSI EN 302 637-3, clause 8.2.1.1
         */

        testcase TC_DEN_KAFW_BV_05() runs on ItsDenm system ItsDenmSystem {
             
            f_DEN_KAFW_BV_05();
             
        } // end TC_DEN_KAFW_BV_05
       
        /**
         * @desc    Check that forwarding ITS-S does not change referenceTime
         * <pre>
         * PICS Selection: PICS_KAF
         * Initial conditions:
         *  with {
         *      the IUT being in the "initial state"
         *      and the IUT having received a DENM
         *          containing actionID
         *              indicating ACTION_ID1
         *          and containing transmissionInterval
         *              indicating TRANS_INTERVAL1
         *          and containing validityDuration
         *              indicating value DURATION_1 more than 3 times greater than TRANS_INTERVAL1
         *          and containing referenceTime
         *              indicating REFERENCETIME_1
         *      and the IUT having starting timer T_Forwarding for this DENM
         *      and the IUT not having received further DENM
         *          containing actionID
         *              indicating ACTION_ID1
         *  }
         * Expected behaviour:
         *  ensure that {
         *      when {
         *          the timer T_Forwarding expires
         *      }
         *      then {
         *          the IUT reconstructs and sends the DENM associated to ACTION_ID1
         *              containing management container
         *                  containing referenceTime
         *                      indicating REFERENCETIME_1
         *      }
         *  }
         * </pre>
         *
         * @see     ETSI TS 102 869-2 v1.4.1 TP/DEN/KAFW/BV-06, ETSI EN 302 637-3, clause 8.2.1.2
         */

        testcase TC_DEN_KAFW_BV_06() runs on ItsDenm system ItsDenmSystem {
             
            f_DEN_KAFW_BV_06();
             
        } // end TC_DEN_KAFW_BV_06

        /**
         * @desc    Check that forwarding ITS-S does not change termination
         * <pre>
         * PICS Selection: PICS_KAF
         * Initial conditions:
         *  with {
         *      the IUT being in the "initial state"
         *      and the IUT having received a DENM
         *          containing actionID
         *              indicating ACTION_ID1
         *          and containing transmissionInterval
         *              indicating TRANS_INTERVAL1
         *          and containing validityDuration
         *              indicating value DURATION_1 more than 3 times greater than TRANS_INTERVAL1
         *          and containing termination
         *              indicating isNegation
         *      and the IUT having starting timer T_Forwarding for this DENM
         *      and the IUT not having received further DENM
         *          containing actionID
         *              indicating ACTION_ID1
         *  }
         * Expected behaviour:
         *  ensure that {
         *      when {
         *          the timer T_Forwarding expires
         *      }
         *      then {
         *          the IUT reconstructs and sends the DENM associated to ACTION_ID1
         *              containing management container
         *                  containing termination
         *                      indicating isNegation
         *      }
         *  }
         * </pre>
         *
         * @see     ETSI TS 102 869-2 v1.4.1 TP/DEN/KAFW/BV-07, ETSI EN 302 637-3, clause 8.2.1.3
         */

        testcase TC_DEN_KAFW_BV_07() runs on ItsDenm system ItsDenmSystem {
             
            f_DEN_KAFW_BV_07();
             
        } // end TC_DEN_KAFW_BV_07

        /**
         * @desc    Check that Forwarding ITS-S does not modify management, situation, location and alacarte containers
         *          when forwarding a DENM
         * <pre>
         * PICS Selection: PICS_KAF
         * Initial conditions:
         *  with {
         *      the IUT being in the "initial state"
         *      and the IUT having received a DENM
         *          containing management container
         *              indicating MANACEMENTCONTAINER_1
         *          and containing situation container
         *              indicating SITUATION_1
         *          and containing location container
         *              indicating LOCATION_1
         *          and containing alacarte container
         *              indicating ALACARTE_1
         *          and containing transmissionInterval
         *              indicating TRANS_INTERVAL1
         *      and the IUT having starting timer T_Forwarding for this DENM
         *      and the IUT not having received further DENM
         *          containing actionID
         *              indicating ACTION_ID1
         *  }
         * Expected behaviour:
         *  ensure that {
         *      when {
         *          the timer T_Forwarding expires
         *      }
         *      then {
         *          the IUT reconstructs and sends the DENM associated to ACTION_ID1
         *              containing management container
         *                  indicating MANACEMENTCONTAINER_1
         *              and containing situation container
         *                  indicating SITUATION_1
         *              and containing location container
         *                  indicating LOCATION_1
         *              and containing alacarte container
         *                  indicating ALACARTE_1
         *      }
         *  }
         * </pre>
         *
         * @see     ETSI TS 102 869-2 v1.4.1 TP/DEN/KAFW/BV-08, ETSI EN 302 637-3, clause 8.2.1.6
         */

        testcase TC_DEN_KAFW_BV_08() runs on ItsDenm system ItsDenmSystem {
             
            f_DEN_KAFW_BV_08();
             
        } // end TC_DEN_KAFW_BV_08

        /**
         * @desc    Check that forwarding ITS-S stops forwarding DENM after validity expiration
         * <pre>
         * PICS Selection: PICS_KAF
         * Initial conditions:
         *  with {
         *      the IUT being in the "initial state"
         *      and the IUT having received an event
         *          containing management container
         *              containing actionID
         *                  indicating ACTION_ID1
         *              and containing validityDuration
         *                  indicating DURATION_1
         *              and containing transmissionInterval
         *                      indicating TRANS_INTERVAL1
         *      and the IUT having starting timer T_Forwarding for this DENM
         *      and the IUT not having received further DENM
         *          containing actionID
         *              indicating ACTION_ID1
         *  }
         * Expected behaviour:
         *  ensure that {
         *      when {
         *          the IUT is alerted of expiration of the time associated with DURATION_1
         *      }
         *      then {
         *          the IUT stops to reconstruct and to send the DENM associated with ACTION_ID1
         *      }
         *  }
         * </pre>
         *
         * @see     ETSI TS 102 869-2 v1.4.1 TP/DEN/KAFW/BV-09, ETSI EN 302 637-3, clause 8.2.2
         */

        testcase TC_DEN_KAFW_BV_09() runs on ItsDenm system ItsDenmSystem {
             
            f_DEN_KAFW_BV_09();
             
        } // end TC_DEN_KAFW_BV_09
                                 
        /**
         * @desc    Check that forwarding ITS-S stops forwarding DENM if it is outside relevance area
         * <pre>
         * PICS Selection: PICS_KAF
         * Initial conditions:
         *  with {
         *      the IUT being in the "initial state"
         *      and the IUT having received an event
         *          containing management container
         *              containing actionID
         *                  indicating ACTION_ID1
         *              and containing transmissionInterval
         *                      indicating TRANS_INTERVAL1
         *      and the IUT having starting timer T_Forwarding for this DENM
         *      and the IUT not having received further DENM
         *          containing actionID
         *              indicating ACTION_ID1
         *  }
         * Expected behaviour:
         *  ensure that {
         *      when {
         *          the IUT is alerted that its position is now outside of the relevance area associated with ACTION_ID1
         *      }
         *      then {
         *          the IUT stops to reconstruct and to send the DENM associated with ACTION_ID1
         *      }
         *  }
         * </pre>
         *
         * @see     ETSI TS 102 869-2 v1.4.1 TP/DEN/KAFW/BV-10, ETSI EN 302 637-3, clause 8.2.2
         */

        testcase TC_DEN_KAFW_BV_10() runs on ItsDenm system ItsDenmSystem {
             
            f_DEN_KAFW_BV_10();
             
        } // end TC_DEN_KAFW_BV_10
                                   
        /**
         * @desc    Check that forwarding ITS-S does not forward DENM is transmissionInterval is not present
         * <pre>
         * PICS Selection: PICS_KAF
         * Initial conditions:
         *  with {
         *      the IUT being in the "initial state"
         *  }
         * Expected behaviour:
         *  ensure that {
         *      when {
         *          the IUT receives a DENM
         *              containing actionID
         *                      indicating ACTION_ID1
         *              and not containing transmissionInterval
         *      }
         *      then {
         *          the IUT does not reconstruct and send the DENM associated with ACTION_ID1
         *      }
         *  }
         * </pre>
         *
         * @see     ETSI TS 102 869-2 v1.4.1 TP/DEN/KAFW/BV-10, ETSI EN 302 637-3, clause 8.2.2
         */

        testcase TC_DEN_KAFW_BV_11() runs on ItsDenm system ItsDenmSystem {
             
            f_DEN_KAFW_BV_11();
             
        } // end TC_DEN_KAFW_BV_11
       
    } // end denKeepAliveForwarding
   
} // end ItsDenm_TestCases