Logo etsi

ETSI's Bug Tracker

Notice: information submitted on the ETSI issue Tracker may be incorporated in ETSI publication(s) and therefore subject to the ETSI IPR policy.

View Issue Details Jump to Notes ] Issue History ] Print ]
IDProjectCategoryView StatusDate SubmittedLast Update
0008132SOL001 - TOSCA-based NFV descriptors spec[NFV Specifications] Bugpublic16-09-2022 08:2416-09-2022 08:24
ReporterSujeet Banerjee 
Assigned To 
Prioritynormal 
StatusnewResolutionopen 
Product Version4.2.1 
Target VersionFixed in Version 
Summary0008132: [V4.3.1] [Clause: 6.2.12.2] INCORRECT constraints defined for 'max_number_of _instances'
DescriptionAs per the IFA011 "VduProfile" information element, the 'max' constraint is "mandatory" and must be "greater than zero".

The Clause 6.2.12.2 in SOL001 V4.3.1 specified INCORRECT constraint for "max_number_of_instances" as "greater_or_equal:0"

This does not make sense, as the field is mandatory, and the max constraint cannot be allowed to be '0' ever.
Additional InformationThe constraints are incorrect at multiple occurrences for 'max_number_**' in the SOL001 V4.3.1 (and V4.2.1) specification.
TagsNo tags attached.
Attached Files

- Relationships

-  Notes
There are no notes attached to this issue.

- Issue History
Date Modified Username Field Change
16-09-2022 08:24 Sujeet Banerjee New Issue
15-12-2022 09:18 Sujeet Banerjee Issue cloned: 0008176