View Issue Details [ Jump to Notes ] | [ Issue History ] [ Print ] |
ID | Project | Category | View Status | Date Submitted | Last Update |
0007770 | Common Library | Bug report | public | 29-05-2018 09:21 | 29-05-2018 09:21 |
|
Reporter | tepelmannd | |
Assigned To | Sebastian Muellers | |
Priority | immediate | Severity | major | Reproducibility | have not tried |
Status | assigned | Resolution | open | |
Platform | | OS | | OS Version | |
|
Summary | 0007770: Incorrect usage of present template for send function |
Description | In the function f_serverSyncClientsTimedIntermediateSync the template (present) parameter p_syncIdIntermediate is incorrectly used for the call f_serverSendToAllClients with the parameter m_syncServerReady which is used inside the function for sending.
Proposed solution: Re-use the received sync id which is a value as input for sending.
Attached a correct version of the LibCommonSync module. |
Additional Information | The attached module also fixes the incorrect usage (by ETSI's naming convention) of the prefix 'm_' for m_syncClientReady/m_syncServerReady using a 'non-value' template flavour. New templates with the correct usage of the naming convention have been introduced.
Additionally incorrect prefix for T3doc comments have been fixed. |
Tags | No tags attached. |
|
Attached Files | LibCommon_Sync.ttcn [^] (63,232 bytes) 29-05-2018 09:21 |
|