View Issue Details Jump to Notes ] Issue History ] Print ]
IDProjectCategoryView StatusDate SubmittedLast Update
0007770Common LibraryBug reportpublic29-05-2018 09:2129-05-2018 09:21
Reportertepelmannd 
Assigned ToSebastian Muellers 
PriorityimmediateSeveritymajorReproducibilityhave not tried
StatusassignedResolutionopen 
PlatformOSOS Version
Summary0007770: Incorrect usage of present template for send function
DescriptionIn the function f_serverSyncClientsTimedIntermediateSync the template (present) parameter p_syncIdIntermediate is incorrectly used for the call f_serverSendToAllClients with the parameter m_syncServerReady which is used inside the function for sending.

Proposed solution: Re-use the received sync id which is a value as input for sending.

Attached a correct version of the LibCommonSync module.
Additional InformationThe attached module also fixes the incorrect usage (by ETSI's naming convention) of the prefix 'm_' for m_syncClientReady/m_syncServerReady using a 'non-value' template flavour. New templates with the correct usage of the naming convention have been introduced.

Additionally incorrect prefix for T3doc comments have been fixed.
TagsNo tags attached.
Attached Files? file icon LibCommon_Sync.ttcn [^] (63,232 bytes) 29-05-2018 09:21

- Relationships

-  Notes
There are no notes attached to this issue.

- Issue History
Date Modified Username Field Change
29-05-2018 09:21 tepelmannd New Issue
29-05-2018 09:21 tepelmannd Status new => assigned
29-05-2018 09:21 tepelmannd Assigned To => Sebastian Muellers
29-05-2018 09:21 tepelmannd File Added: LibCommon_Sync.ttcn