(0015056)
|
mortona
|
10-02-2018 13:58
(edited on: 15-02-2018 17:16) |
|
I'm sorry Bruno, but I believe the Reference to clause 5.1 is correct,
but I now see the problem - I have been looking at "INF" and reading
"IFA" in my mind.
The paragraph in TST008 says:
The measured NFVI resources and the measurement processes shall be completely specified in the dimensions of model numbers, firmware versions, software versions, and any other aspects that influence the results (such as physical location of the components within a datacentre's racks and shelves). For example, the fixed frequency of the physical CPU clock in Hz, which governs the rate that the CPU executes instructions, is one important descriptor of the NFVI. Clock Speed may depend on other CPU settings, such as energy-saving power control. For one list of NFVI platform descriptors, see clause 5.1 of ETSI GS NFV-INF 003 [i.1].
and in *IFA*003, clause 5.1, you will find the intended list of parameters, which includes an item that expands on the CPU example given in the TST-008 text above:
• CPU manufacturer, model, configuration (e.g. speed), stepping level, number of cores, hyper threading (or equivalent) status: enabled or disabled, cache size
It seems that we need to add an Informational reference to IFA003, which was intended.
|
|