0007695TDLClarificationpublic10-08-2017 14:5021-08-2017 17:12
Gusztáv Adamis 
Philip Makedonski 
normalminorhave not tried
resolvedfixed 
6.3.4
 STF 522
0007695: TDL MM - Clarification of 6.3.4 DataInstanceUse
a.)
In case it refers to a 'StructuredDataInstance', its value may be modified inline by providing arguments as 'ParameterBinding's. This allows replacing the current value of the referenced 'Member' with a new value evaluated from the provided 'DataUse' specification.

Proposed new text:
In case it refers to a 'StructuredDataInstance' and argument(s) as 'ParameterBinding'(s) is (are) provided, then the value of the referred 'StructuredDataInstance' will be used with replaced value(s) of the referenced 'Member'(s) evaluated from the provided 'DataUse' specification of the corresponding 'ParameterBinding'.
NOTE: The value of the referred 'StructuredDataInstance' remains unchanged.

b.)
Constraints
• 'DataInstance' reference or non-empty 'argument'
Either a 'dataInstance' or a non-empty 'argument' set shall be specified.

Proposed new text:
If 'DataInstance' is not referred then the argument list must not be empty.
No tags attached.
Issue History
10-08-2017 14:50Gusztáv AdamisNew Issue
21-08-2017 17:12Philip MakedonskiNote Added: 0014801
21-08-2017 17:12Philip MakedonskiStatusnew => resolved
21-08-2017 17:12Philip MakedonskiResolutionopen => fixed
21-08-2017 17:12Philip MakedonskiAssigned To => Philip Makedonski

Notes
(0014801)
Philip Makedonski   
21-08-2017 17:12   
Changed as proposed.