ETSI's Bug Tracker - CDD ASN.1 (TS 102 894-2)
View Issue Details
0007091CDD ASN.1 (TS 102 894-2)New Featurepublic23-06-2015 01:4310-01-2017 16:13
linla 
Yann Garcia 
highmajorhave not tried
resolvedfixed 
TS 102 894-2 V1.2.1 
Next Release 
0007091: [ProtectedZoneType]: extention with temporary Cen DSRC type
To include additional value to be in line with the published TS 102 792 (CEN DSRC co-existance).

ProtectedZoneType::= ENUMERATED { permanentCenDsrcTolling (0), temporaryCenDsrcTolling (1), ... }
No tags attached.
Issue History
23-06-2015 01:43linlaNew Issue
23-06-2015 01:43linlaStatusnew => assigned
23-06-2015 01:43linlaAssigned To => Lan LIN
27-10-2015 12:34linlaNote Added: 0013429
27-10-2015 12:36linlaNote Added: 0013430
27-10-2015 12:36linlaStatusassigned => resolved
27-10-2015 12:36linlaResolutionopen => fixed
04-04-2016 16:02Sebastian MuellersStatusresolved => confirmed
04-04-2016 16:36Sebastian MuellersNote Added: 0013916
04-04-2016 16:38Sebastian MuellersNote Added: 0013918
04-04-2016 16:38Sebastian MuellersStatusconfirmed => assigned
05-04-2016 15:59Sebastian MuellersNote Added: 0013927
12-04-2016 13:40linlaNote Added: 0013931
12-04-2016 13:40linlaStatusassigned => confirmed
18-04-2016 14:20Sebastian MuellersAssigned ToLan LIN => Yann Garcia
18-04-2016 14:20Sebastian MuellersStatusconfirmed => assigned
22-04-2016 08:30Yann GarciaNote Added: 0013948
22-04-2016 08:30Yann GarciaStatusassigned => resolved
21-09-2016 13:54Sebastian MuellersNote Added: 0014209
09-01-2017 14:53linlaNote Added: 0014480
10-01-2017 16:13linlaNote Edited: 0014480bug_revision_view_page.php?bugnote_id=14480#r364

Notes
(0013429)
linla   
27-10-2015 12:34   
the proposal is approved in ITS WG1#633 meeting
(0013430)
linla   
27-10-2015 12:36   
approved by ITS WG1#33 meeting
(0013916)
Sebastian Muellers   
04-04-2016 16:36   
this change is not backward compatibile and requires an update of CDD version to V2
(0013918)
Sebastian Muellers   
04-04-2016 16:38   
please approve at ITSWG1#35
(0013927)
Sebastian Muellers   
05-04-2016 15:59   
correction of previous statement: this CR is backward compatible
(0013931)
linla   
12-04-2016 13:40   
approved in ITS WG1#35
(0013948)
Yann Garcia   
22-04-2016 08:30   
Implemented
(0014209)
Sebastian Muellers   
21-09-2016 13:54   
backwards compatible way is +ProtectedZoneType::= ENUMERATED { permanentCenDsrcTolling (0), ..., temporaryCenDsrcTolling (1) }
(0014480)
linla   
09-01-2017 14:53   
(edited on: 10-01-2017 16:13)
implemented in CDD V1.2.3 in Jan 2017