ETSI's Bug Tracker - CAM
View Issue Details
0006902CAMATSpublic05-03-2015 10:3705-03-2015 10:49
tepelmann 
tepelmann 
normalminorhave not tried
resolvedfixed 
Next Release 
Next Release 
0006902: TC_CAM_MSD_GFQ_BV_05: UtChangePosition uses absolute value instead of offset
In the test purpose function f_CAM_MSD_GFQ_BV_05 a new position if computed using f_computePositionUsingDistance as reference position.
In the next step this absoulte reference position is used for changing the position.
However it should just be the offset between the positions.
No tags attached.
Issue History
05-03-2015 10:37tepelmannNew Issue
05-03-2015 10:49tepelmannNote Added: 0012810
05-03-2015 10:49tepelmannStatusnew => resolved
05-03-2015 10:49tepelmannResolutionopen => fixed
05-03-2015 10:49tepelmannAssigned To => tepelmann

Notes
(0012810)
tepelmann   
05-03-2015 10:49   
Using now the difference between the actual and the computed position.