ETSI's Bug Tracker - CAM
View Issue Details
0005529CAMBase Specpublic11-05-2010 15:2313-04-2015 08:33
Andras Kovacs 
user609 
normalmajorN/A
closedfixed 
TS102637-2 v1.0.4 
Next Release 
0005529: TS102637-2 v1.0.4 / chapter 5.1: manufacturer objectives and system objectives seem to be set oppositely
Section 5.1 elaborates on the minimum CAM frequency per use case, from the point of view of minimizing wireless congestion while meeting functional requirements.
However since maximum CAM frequency of 10 Hz is allowed for ALL use cases, the manufacturers' objective of designing a simplest conformant system is met by fixing CAM frequency to a constant value of 10 Hz. This contradiction negates the meaning of all the elaboration in section 5.1.
No tags attached.
Issue History
11-05-2010 15:23Andras KovacsNew Issue
12-05-2010 09:39Sebastian MuellersNote Added: 0009346
01-06-2010 17:20Sebastian MuellersStatusnew => assigned
01-06-2010 17:20Sebastian MuellersAssigned To => user609
15-07-2010 15:49Sebastian MuellersProduct Version => TS102637-2 v1.0.4
21-07-2010 15:23Sebastian MuellersStatusassigned => resolved
21-07-2010 15:23Sebastian MuellersFixed in Version => Next Release
21-07-2010 15:23Sebastian MuellersResolutionopen => fixed
21-07-2010 15:23Sebastian MuellersNote Added: 0009546
13-04-2015 08:33Sebastian MuellersNote Added: 0012895
13-04-2015 08:33Sebastian MuellersStatusresolved => closed

Notes
(0009346)
Sebastian Muellers   
12-05-2010 09:39   
The paragraph below table 1 defines rules which allow for "min time interval = 0.1" which means max freq of 10 Hz for all UCs (Slow Vehicle Indication etc)
(0009546)
Sebastian Muellers   
21-07-2010 15:23   
to be clarified in the next release
(0012895)
Sebastian Muellers   
13-04-2015 08:33   
old issues